Description
[{“name”:”Item”,”normalizedValue”:”Circuit Breaker”,”rank”:1,”value”:”Circuit Breaker”},{“name”:”Amps”,”normalizedValue”:”175″,”rank”:2,”value”:”175 A”},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:3,”value”:”600V AC”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:4,”value”:”Not Rated”},{“name”:”Curve Type”,”normalizedValue”:”A”,”rank”:5,”value”:”A”},{“name”:”Max. AIR Rating”,”normalizedValue”:”35 kA at 480V AC”,”rank”:6,”value”:”35 kA at 480V AC”},{“name”:”Terminal Connection”,”normalizedValue”:”Standard Terminals Load Only”,”rank”:7,”value”:”Standard Terminals Load Only”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:9,”value”:”3″},{“name”:”Frame Size”,”normalizedValue”:”225A/Frame 2″,”rank”:12,”value”:”225A/Frame 2″},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:14,”value”:”Standard”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, IEC 60947-2, UL 489″,”rank”:15,”value”:”CCC, CSA, IEC 60947-2, UL 489″},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”value”:”Fixed”},{“name”:”Min. Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Frame Type”,”normalizedValue”:”Complete Breaker”,”value”:”Complete Breaker”},{“name”:”Width”,”normalizedValue”:”4.11 in”,”value”:”4.11 in”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”value”:”Thermal Magnetic”},{“name”:”Depth”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Max. Wire Size”,”normalizedValue”:”1/0 AWG”,”value”:”1/0 AWG”},{“name”:”Phase”,”normalizedValue”:”Three”,”value”:”Three”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”value”:”ABC”},{“name”:”Interrupt Rating”,”normalizedValue”:”35 kA at 480V AC, 10 kA at 125V DC”,”value”:”35 kA at 480V AC, 10 kA at 125V DC”},{“name”:”Height”,”normalizedValue”:”6 in”,”value”:”6 in”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Product Height”,”normalizedValue”:”152.4 mm”,”value”:”152.4 mm”},{“name”:”Frame”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Voltage Rating”,”normalizedValue”:”600 Vac”,”value”:”600 Vac”},{“name”:”Certifications”,”normalizedValue”:”CCC Marked,IEC 60947-2,UL 489,CSA”,”value”:”CCC Marked,IEC 60947-2,UL 489,CSA”},{“name”:”Class”,”normalizedValue”:”Class A”,”value”:”Class A”},{“name”:”Switch Off Technique”,”normalizedValue”:”Thermomagnetic”,”value”:”Thermomagnetic”},{“name”:”Rated Operation Voltage (UE) at AC – Max”,”normalizedValue”:”600″,”value”:”600″},{“name”:”Product Length/Depth”,”normalizedValue”:”88.9 mm”,”value”:”88.9 mm”},{“name”:”Product Width”,”normalizedValue”:”104.6 mm”,”value”:”104.6 mm”},{“name”:”Interrupt Rating Range”,”normalizedValue”:”10 kAIC Icu @125 Vdc,65 kAIC @240V (UL),8 kAIC Icu/ 4 kAIC Ics/ 16.8 kAIC Icm @690V (IEC),18 kAIC @600V (UL/CSA),25 kAIC Icu/ 20 kAIC Ics/ 52.5 kAIC Icm @480V Brazil (IEC),10 kAIC Icu @250 Vdc,35 kAIC @480V (UL),36 kAIC Icu/ 36 kAIC Ics/ 75.6 kAIC Icm @380-415V (IEC),30 kAIC Icu/ 22.5 kAIC Ics/ 63 kAIC Icm @440V (IEC),20 kAIC Icu/ 15/13 kAIC Ics/ 42 kAIC Icm @525V South Africa (IEC),55 kAIC Icu/ 55 kAIC Ics/ 121 kAIC Icm @240V (IEC)”,”value”:”10 kAIC Icu @125 Vdc,65 kAIC @240V (UL),8 kAIC Icu/ 4 kAIC Ics/ 16.8 kAIC Icm @690V (IEC),18 kAIC @600V (UL/CSA),25 kAIC Icu/ 20 kAIC Ics/ 52.5 kAIC Icm @480V Brazil (IEC),10 kAIC Icu @250 Vdc,35 kAIC @480V (UL),36 kAIC Icu/ 36 kAIC Ics/ 75.6 kAIC Icm @380-415V (IEC),30 kAIC Icu/ 22.5 kAIC Ics/ 63 kAIC Icm @440V (IEC),20 kAIC Icu/ 15/13 kAIC Ics/ 42 kAIC Icm @525V South Africa (IEC),55 kAIC Icu/ 55 kAIC Ics/ 121 kAIC Icm @240V (IEC)”},{“name”:”Product Name”,”normalizedValue”:”Eaton Power Defense molded case circuit breaker”,”value”:”Eaton Power Defense molded case circuit breaker”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Dominican Republic”,”value”:”Dominican Republic”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.