Description
[{“name”:”Item”,”normalizedValue”:”Circuit Breaker”,”rank”:1,”value”:”Circuit Breaker”},{“name”:”Amps”,”normalizedValue”:”125″,”rank”:2,”value”:”125 A”},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:3,”value”:”600V AC”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:4,”value”:”Not Rated”},{“name”:”Curve Type”,”normalizedValue”:”A”,”rank”:5,”value”:”A”},{“name”:”Max. AIR Rating”,”normalizedValue”:”35 kA at 480V AC”,”rank”:6,”value”:”35 kA at 480V AC”},{“name”:”Terminal Connection”,”normalizedValue”:”Standard Line and Load Lugs”,”rank”:7,”value”:”Standard Line and Load Lugs”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:9,”value”:”3″},{“name”:”Frame Size”,”normalizedValue”:”125A/Frame 1″,”rank”:12,”value”:”125A/Frame 1″},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:14,”value”:”Standard”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, IEC 60947-2, RoHS, UL 489″,”rank”:15,”value”:”CCC, CSA, IEC 60947-2, RoHS, UL 489″},{“name”:”Instantaneous Trip”,”normalizedValue”:”Fixed”,”value”:”Fixed”},{“name”:”Max. Wire Size”,”normalizedValue”:”3/0 AWG”,”value”:”3/0 AWG”},{“name”:”Depth”,”normalizedValue”:”2.99 in”,”value”:”2.99 in”},{“name”:”Trip Type”,”normalizedValue”:”Thermal Magnetic”,”value”:”Thermal Magnetic”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”value”:”ABC”},{“name”:”Min. Wire Size”,”normalizedValue”:”14 AWG”,”value”:”14 AWG”},{“name”:”Interrupt Rating”,”normalizedValue”:”35 kA at 480V AC, 35 kA at 480V”,”value”:”35 kA at 480V AC, 35 kA at 480V”},{“name”:”Frame Type”,”normalizedValue”:”Complete Breaker”,”value”:”Complete Breaker”},{“name”:”Height”,”normalizedValue”:”5-1/2 in”,”value”:”5.5 in”},{“name”:”Width”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Phase”,”normalizedValue”:”Three”,”value”:”Three”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Switch Off Technique”,”normalizedValue”:”Thermomagnetic”,”value”:”Thermomagnetic”},{“name”:”Product Width”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Product Name”,”normalizedValue”:”Eaton Power Defense molded case circuit breaker”,”value”:”Eaton Power Defense molded case circuit breaker”},{“name”:”Terminals”,”normalizedValue”:”Standard Line and Load”,”value”:”Standard Line and Load”},{“name”:”Product Length/Depth”,”normalizedValue”:”7 in”,”value”:”7 in”},{“name”:”Interrupt Rating Range”,”normalizedValue”:”35 kAIC @480V (UL),22 kAIC Icu @250 Vdc,36 kAIC Icu/ 36 kAIC Ics/ 76 kAIC Icm @380-415V (IEC),18 kAIC @600V (UL/CSA),65 kAIC @240V (UL),22 kAIC Icu @125 Vdc,55 kAIC Icu/ 55 kAIC Ics/ 121 kAIC Icm @240V (IEC)”,”value”:”35 kAIC @480V (UL),22 kAIC Icu @250 Vdc,36 kAIC Icu/ 36 kAIC Ics/ 76 kAIC Icm @380-415V (IEC),18 kAIC @600V (UL/CSA),65 kAIC @240V (UL),22 kAIC Icu @125 Vdc,55 kAIC Icu/ 55 kAIC Ics/ 121 kAIC Icm @240V (IEC)”},{“name”:”Voltage Rating”,”normalizedValue”:”600 Vac”,”value”:”600 Vac”},{“name”:”Class”,”normalizedValue”:”Class A”,”value”:”Class A”},{“name”:”Rated Operation Voltage (UE) at AC – Max”,”normalizedValue”:”600″,”value”:”600″},{“name”:”Product Height”,”normalizedValue”:”4-1/2 in”,”value”:”4.5 in”},{“name”:”Certifications”,”normalizedValue”:”IEC 60947-2,CCC Marked,UL 489,CSA”,”value”:”IEC 60947-2,CCC Marked,UL 489,CSA”},{“name”:”Frame”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Dominican Republic”,”value”:”Dominican Republic”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.