Description
[{“name”:”Item”,”normalizedValue”:”Circuit Breaker”,”rank”:1,”value”:”Circuit Breaker”},{“name”:”Amps”,”normalizedValue”:”1,200″,”rank”:2,”value”:”1,200 A”},{“name”:”AC Voltage Rating”,”normalizedValue”:”600V AC”,”rank”:3,”value”:”600V AC”},{“name”:”DC Voltage Rating”,”normalizedValue”:”Not Rated”,”rank”:4,”value”:”Not Rated”},{“name”:”Curve Type”,”normalizedValue”:”A”,”rank”:5,”value”:”A”},{“name”:”Max. AIR Rating”,”normalizedValue”:”50 kA at 480V AC”,”rank”:6,”value”:”50 kA at 480V AC”},{“name”:”Terminal Connection”,”normalizedValue”:””,”rank”:7,”value”:”Not Applicable”},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:9,”value”:”3″},{“name”:”Frame Size”,”normalizedValue”:”1200A/Frame 5″,”rank”:12,”value”:”1200A/Frame 5″},{“name”:”Circuit Breaker Type”,”normalizedValue”:”Standard”,”rank”:14,”value”:”Standard”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, IEC 60947-2, RoHS, UL 489″,”rank”:15,”value”:”CCC, CSA, IEC 60947-2, RoHS, UL 489″},{“name”:”Min. Wire Size”,”normalizedValue”:”500 AWG”,”value”:”500 AWG”},{“name”:”Phase Connection”,”normalizedValue”:”ABC”,”value”:”ABC”},{“name”:”Phase”,”normalizedValue”:”Three”,”value”:”Three”},{“name”:”For Use With”,”normalizedValue”:”Power Defense”,”value”:”Power Defense”},{“name”:”Trip Type”,”normalizedValue”:”Electronic”,”value”:”Electronic”},{“name”:”Frame Type”,”normalizedValue”:”Complete Breaker”,”value”:”Complete Breaker”},{“name”:”High Amp Trip Setting”,”normalizedValue”:”1,200 A”,”value”:”1200 A”},{“name”:”Depth”,”normalizedValue”:”5-1/2 in”,”value”:”5.5 in”},{“name”:”Height”,”normalizedValue”:”16 in”,”value”:”16 in”},{“name”:”Max. Wire Size”,”normalizedValue”:”4/0 AWG”,”value”:”4/0 AWG”},{“name”:”Interrupt Rating”,”normalizedValue”:”50 kA at 480V AC, 35 kA Icu/22.5 kA Ics/73.5 kA Icm at 480V”,”value”:”50 kA at 480V AC, 35 kA Icu/22.5 kA Ics/73.5 kA Icm at 480V”},{“name”:”Instantaneous Trip”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Width”,”normalizedValue”:”8-1/4 in”,”value”:”8.25 in”},{“name”:”Max. Operating Temp.”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Min. Operating Temp.”,”normalizedValue”:”-4 deg F”,”value”:”-4 Degrees F”},{“name”:”Voltage Rating”,”normalizedValue”:”600 Vac”,”value”:”600 Vac”},{“name”:”Product Height”,”normalizedValue”:”406.4 mm”,”value”:”406.4 mm”},{“name”:”Product Name”,”normalizedValue”:”Eaton Power Defense molded case circuit breaker”,”value”:”Eaton Power Defense molded case circuit breaker”},{“name”:”Class”,”normalizedValue”:”Class A”,”value”:”Class A”},{“name”:”Frame”,”normalizedValue”:”5″,”value”:”5″},{“name”:”Product Length/Depth”,”normalizedValue”:”139.7 mm”,”value”:”139.7 mm”},{“name”:”Terminals”,”normalizedValue”:”No Terminals”,”value”:”No Terminals”},{“name”:”Product Width”,”normalizedValue”:”209.5 mm”,”value”:”209.5 mm”},{“name”:”Certifications”,”normalizedValue”:”IEC 60947-2,UL 489,CCC Marked,CSA”,”value”:”IEC 60947-2,UL 489,CCC Marked,CSA”},{“name”:”Interrupt Rating Range”,”normalizedValue”:”35 kAIC Icu/ 22.5 kAIC Ics/ 73.5 kAIC Icm @480V Brazil (IEC),25 kAIC Icu/ 20 kAIC Ics/ 52.5 kAIC Icm @525V South Africa (IEC),50 kAIC @480/277V (UL),85 kAIC Icu/ 85 kAIC Ics/ 187 kAIC Icm @240V (IEC),50 kAIC Icu/ 50 kAIC Ics/ 105 kAIC Icm @380-415V (IEC),25 kAIC @600/347V (UL),10 kAIC Icu/ 5 kAIC Ics/ 21 kAIC Icm @690V (IEC),35 kAIC Icu/ 35 kAIC Ics/ 73.5 kAIC Icm @440V (IEC),85 kAIC @240V (UL)”,”value”:”35 kAIC Icu/ 22.5 kAIC Ics/ 73.5 kAIC Icm @480V Brazil (IEC),25 kAIC Icu/ 20 kAIC Ics/ 52.5 kAIC Icm @525V South Africa (IEC),50 kAIC @480/277V (UL),85 kAIC Icu/ 85 kAIC Ics/ 187 kAIC Icm @240V (IEC),50 kAIC Icu/ 50 kAIC Ics/ 105 kAIC Icm @380-415V (IEC),25 kAIC @600/347V (UL),10 kAIC Icu/ 5 kAIC Ics/ 21 kAIC Icm @690V (IEC),35 kAIC Icu/ 35 kAIC Ics/ 73.5 kAIC Icm @440V (IEC),85 kAIC @240V (UL)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.