Cable Pull Switch, Right, 2NO+2NC, 24/120V

$443,99

Emergency Cable Pull Switch, Switch Function Maintained, Mounting Style Single End, AC Contact Rating 3 A @ 240 V, Contact Form 1NO/1NC, Push Button Reset, Max. Cable Span 165 ft, Operating Force Not Applicable, NEMA Rating 1, 12, 4, Indicator No Indicator, Cable Connection Location Right, Thermal Amperage 10 A, Length 9.0 in, Width 9.02 in, Depth 4.13 in, Switching Ability Single Cable, DC Contact Rating 0.27 A @ 250 V, Min. Current Not Applicable, Case Material Zamak, Wiring Entry 1/2 in NPT

9999 in stock

SKU: GRG0461167 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Emergency Cable Pull Switch”,”rank”:1,”value”:”Emergency Cable Pull Switch”},{“name”:”Switch Function”,”normalizedValue”:”Maintained”,”rank”:2,”value”:”Maintained”},{“name”:”Mounting Style”,”normalizedValue”:”Single End”,”rank”:3,”value”:”Single End”},{“name”:”AC Contact Rating”,”normalizedValue”:”3 A @ 240 V”,”rank”:4,”value”:”3 A @ 240 V”},{“name”:”Contact Form”,”normalizedValue”:”1NO/1NC”,”rank”:5,”value”:”1NO/1NC”},{“name”:”Reset”,”normalizedValue”:”Push Button”,”rank”:6,”value”:”Push Button”},{“name”:”Max. Cable Span”,”normalizedValue”:”165 ft”,”rank”:7,”value”:”165 ft”},{“name”:”Operating Force”,”normalizedValue”:””,”rank”:8,”value”:”Not Applicable”},{“name”:”NEMA Rating”,”normalizedValue”:”1, 12, 4″,”rank”:9,”value”:”1, 12, 4″},{“name”:”Indicator”,”normalizedValue”:”No Indicator”,”rank”:10,”value”:”No Indicator”},{“name”:”Switching Ability”,”normalizedValue”:”Single Cable”,”rank”:11,”value”:”Single Cable”},{“name”:”DC Contact Rating”,”normalizedValue”:”0.27 A @ 250 V”,”rank”:12,”value”:”0.27 A @ 250 V”},{“name”:”IP Rating”,”normalizedValue”:”IP65″,”value”:”IP65″},{“name”:”Thermal Amperage”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Length”,”normalizedValue”:”9 in”,”value”:”9.0 in”},{“name”:”Wiring Entry”,”normalizedValue”:”1/2 in NPT”,”value”:”1/2 in NPT”},{“name”:”Depth”,”normalizedValue”:”4.13 in”,”value”:”4.13 in”},{“name”:”Min. Current”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Width”,”normalizedValue”:”9.02 in”,”value”:”9.02 in”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC”,”value”:”CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC”},{“name”:”For Use With”,”normalizedValue”:”Preventa XPS Safety Relays”,”value”:”Preventa XPS Safety Relays”},{“name”:”Cable Connection Location”,”normalizedValue”:”Right”,”value”:”Right”},{“name”:”Case Material”,”normalizedValue”:”Zamak”,”value”:”Zamak”},{“name”:”Length (Straight Wireway)”,”normalizedValue”:”9 in”,”value”:”9.0 in”},{“name”:”Contact Operation”,”normalizedValue”:”slow-break”,”value”:”slow-break”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14″,”value”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14″},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”,”value”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”},{“name”:”Positive Opening”,”normalizedValue”:”with EN/IEC 60947-5-1″,”value”:”with EN/IEC 60947-5-1″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV EN/IEC 60947-1″,”value”:”6 kV EN/IEC 60947-1″},{“name”:”Device Short Name”,”normalizedValue”:”XY2CE”,”value”:”XY2CE”},{“name”:”Shock Resistance”,”normalizedValue”:”50 gn 11 ms EN/IEC 60068-2-27″,”value”:”50 gn 11 ms EN/IEC 60068-2-27″},{“name”:”Maximum Resistance Across Terminals”,”normalizedValue”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”,”value”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”},{“name”:”Trigger Cable Anchor Point”,”normalizedValue”:”RH side”,”value”:”RH side”},{“name”:”Tightening Torque”,”normalizedValue”:”0.8-1.2 N.m”,”value”:”0.8-1.2 N.m”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Product Certifications”,”normalizedValue”:”UL category NISD emergency stop devices || CSA || CCC”,”value”:”UL category NISD emergency stop devices || CSA || CCC”},{“name”:”Cable Entry Number”,”normalizedValue”:”3 plain hole Pg 13.5 or ISO M20 cable gland”,”value”:”3 plain hole Pg 13.5 or ISO M20 cable gland”},{“name”:”Short-Circuit Protection”,”normalizedValue”:”10 A cartridge fuse gG EN/IEC 60269″,”value”:”10 A cartridge fuse gG EN/IEC 60269″},{“name”:”Contacts Type And Composition”,”normalizedValue”:”1 NC + 1 NO”,”value”:”1 NC + 1 NO”},{“name”:”Distance Between Cable Supports”,”normalizedValue”:”5-5 m”,”value”:”5-5 m”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NC || NO”,”value”:”(21-22)NC || (13-14)NO”},{“name”:”Compatibility Code”,”normalizedValue”:”XY2CE”,”value”:”XY2CE”},{“name”:”Vibration Resistance”,”normalizedValue”:”10 gn 10-300 Hz)EN/IEC 60068-2-6″,”value”:”10 gn 10-300 Hz)EN/IEC 60068-2-6″},{“name”:”Cover Material”,”normalizedValue”:”Stainless Steel”,”value”:”stainless steel”},{“name”:”Mechanical Durability”,”normalizedValue”:”60,000 cycle”,”value”:”60000 cycles”},{“name”:”Overvoltage Category”,”normalizedValue”:”class I EN/IEC 61140 || class I NF C 20-030″,”value”:”class I EN/IEC 61140 || class I NF C 20-030″},{“name”:”Local Signalling”,”normalizedValue”:”without pilot light”,”value”:”without pilot light”},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP66 IEC 60529″,”value”:”IP66 IEC 60529″},{“name”:”Safety Level”,”normalizedValue”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″,”value”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”,”value”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Product Or Component Type”,”normalizedValue”:”latching emergency stop rope pull switch”,”value”:”latching emergency stop rope pull switch”},{“name”:”Body Material”,”normalizedValue”:”zamak”,”value”:”zamak”},{“name”:”Series”,”normalizedValue”:”XY2C”,”value”:”XY2C”},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NC || NO”,”value”:”(21-22)NC || (13-14)NO”},{“name”:”Cable Span – Maximum”,”normalizedValue”:”164 ft”,”value”:”164 ft”},{“name”:”Action”,”normalizedValue”:”Maintained”,”value”:”Maintained”},{“name”:”Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Overall Depth”,”normalizedValue”:”4.13 in”,”value”:”4.13 in”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”12, 4, 1″,”value”:”1, 12, 4″},{“name”:”Overall Width”,”normalizedValue”:”9.02 in”,”value”:”9.02 in”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”18 mo”,”value”:”18 mo”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Morocco”,”value”:”Morocco”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Cable Pull Switch, Right, 2NO+2NC, 24/120V”