Cable Pull Switch 240Vac 10A Xy2C

$339,99

Cable Pull Switch

Out of stock

SKU: GRG0557980 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Cable Pull Switch”,”rank”:1,”value”:”Cable Pull Switch”},{“name”:”Reset”,”normalizedValue”:”by push-button”,”rank”:6,”value”:”by booted push-button”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-5-1 || EN/IEC 60204-1 || machinery directive 2006/42/EC || EN/IEC 60947-5-5 || EN/ISO 13850 || work equipment directive 2009/104/EC”,”value”:”EN/IEC 60947-5-1 || EN/IEC 60204-1 || machinery directive 2006/42/EC || EN/IEC 60947-5-5 || EN/ISO 13850 || work equipment directive 2009/104/EC”},{“name”:”Series”,”normalizedValue”:”XY2CH”,”value”:”XY2CH”},{“name”:”Body Material”,”normalizedValue”:”zamak”,”value”:”zamak”},{“name”:”Local Signalling”,”normalizedValue”:”without pilot light”,”value”:”without pilot light”},{“name”:”Positive Opening”,”normalizedValue”:”with EN/IEC 60947-5-1″,”value”:”with EN/IEC 60947-5-1″},{“name”:”Distance Between Cable Supports”,”normalizedValue”:”5-5 m”,”value”:”5-5 m”},{“name”:”Trigger Cable Maximum Length”,”normalizedValue”:”30 m”,”value”:”30 m”},{“name”:”Cover Material”,”normalizedValue”:”Stainless Steel”,”value”:”stainless steel”},{“name”:”Mechanical Durability”,”normalizedValue”:”800,000 cycle”,”value”:”800000 cycles”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV EN/IEC 60947-1″,”value”:”6 kV EN/IEC 60947-1″},{“name”:”Cable Entry Number”,”normalizedValue”:”3 tapped entry Pg 13.5 cable gland”,”value”:”3 tapped entry Pg 13.5 cable gland”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”1 NC + 1 NO”,”value”:”1 NC + 1 NO”},{“name”:”Product Or Component Type”,”normalizedValue”:”latching emergency stop rope pull switch”,”value”:”latching emergency stop rope pull switch”},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NO || NC”,”value”:”(13-14)NO || (21-22)NC”},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508″,”value”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508″},{“name”:”Housing Colour”,”normalizedValue”:”red RAL 3000″,”value”:”red RAL 3000″},{“name”:”Trigger Cable Anchor Point”,”normalizedValue”:”RH or LH side”,”value”:”RH or LH side”},{“name”:”Tightening Torque”,”normalizedValue”:”0.8-1.2 N.m”,”value”:”0.8-1.2 N.m”},{“name”:”Number Of Cables”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Vibration Resistance”,”normalizedValue”:”10 gn 10-150 Hz)EN/IEC 60068-2-6″,”value”:”10 gn 10-150 Hz)EN/IEC 60068-2-6″},{“name”:”Shock Resistance”,”normalizedValue”:”50 gn 11 ms EN/IEC 60068-2-27″,”value”:”50 gn 11 ms EN/IEC 60068-2-27″},{“name”:”Safety Level”,”normalizedValue”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″,”value”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Overvoltage Category”,”normalizedValue”:”class I EN/IEC 61140 || class I NF C 20-030″,”value”:”class I EN/IEC 61140 || class I NF C 20-030″},{“name”:”Device Short Name”,”normalizedValue”:”XY2CH”,”value”:”XY2CH”},{“name”:”Contact Operation”,”normalizedValue”:”slow-break”,”value”:”slow-break”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP65 IEC 60529″,”value”:”IP65 IEC 60529″},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”,”value”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”},{“name”:”Short-Circuit Protection”,”normalizedValue”:”10 A cartridge fuse gG EN/IEC 60269″,”value”:”10 A cartridge fuse gG EN/IEC 60269″},{“name”:”Compatibility Code”,”normalizedValue”:”XY2CH”,”value”:”XY2CH”},{“name”:”Product Certifications”,”normalizedValue”:”UL category NISD emergency stop devices || CCC”,”value”:”UL category NISD emergency stop devices || CCC”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”,”value”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”Maximum Resistance Across Terminals”,”normalizedValue”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”,”value”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Morocco”,”value”:”Morocco”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Cable Pull Switch 240Vac 10A Xy2C”