Cable Pull Switch, 10A, Universal, 1NO+1NC, Telemecanique Sensors, Mfr#: XY2CH13150H7

$344,99

Emergency Cable Pull Switch, Switch Function Maintained, Mounting Style Single End, AC Contact Rating 3 A @ 240 V, Contact Form 1NO/1NC, Push Button Reset, Max. Cable Span 50 ft, Operating Force 4.5 lb, NEMA Rating 1, 12, 4, Indicator No Indicator, Cable Connection Location Left or Right, Thermal Amperage 10 A, Length 7.76 in, Width 2.68 in, Depth 1.57 in, Switching Ability Single Cable, DC Contact Rating 0.27 A @ 250 V, Min. Current Not Applicable, Case Material Zamak, Wiring Entry 1/2 in NPT

9999 in stock

SKU: GRG4091437 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Emergency Cable Pull Switch”,”rank”:1,”value”:”Emergency Cable Pull Switch”},{“name”:”Switch Function”,”normalizedValue”:”Maintained”,”rank”:2,”value”:”Maintained”},{“name”:”Mounting Style”,”normalizedValue”:”Single End”,”rank”:3,”value”:”Single End”},{“name”:”AC Contact Rating”,”normalizedValue”:”3 A @ 240 V”,”rank”:4,”value”:”3 A @ 240 V”},{“name”:”Contact Form”,”normalizedValue”:”1NO/1NC”,”rank”:5,”value”:”1NO/1NC”},{“name”:”Reset”,”normalizedValue”:”Push Button”,”rank”:6,”value”:”Push Button”},{“name”:”Max. Cable Span”,”normalizedValue”:”50 ft”,”rank”:7,”value”:”50 ft”},{“name”:”Operating Force”,”normalizedValue”:”4.5 lb”,”rank”:8,”value”:”4.5 lb”},{“name”:”NEMA Rating”,”normalizedValue”:”1, 12, 4″,”rank”:9,”value”:”1, 12, 4″},{“name”:”Indicator”,”normalizedValue”:”No Indicator”,”rank”:10,”value”:”No Indicator”},{“name”:”Switching Ability”,”normalizedValue”:”Single Cable”,”rank”:11,”value”:”Single Cable”},{“name”:”DC Contact Rating”,”normalizedValue”:”0.27 A @ 250 V”,”rank”:12,”value”:”0.27 A @ 250 V”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC”,”value”:”CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC”},{“name”:”Wiring Entry”,”normalizedValue”:”1/2 in NPT”,”value”:”1/2 in NPT”},{“name”:”Width”,”normalizedValue”:”2.68 in”,”value”:”2.68 in”},{“name”:”IP Rating”,”normalizedValue”:”IP65″,”value”:”IP65″},{“name”:”Depth”,”normalizedValue”:”1.57 in”,”value”:”1.57 in”},{“name”:”Thermal Amperage”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Cable Connection Location”,”normalizedValue”:”Left, Right”,”value”:”Left or Right”},{“name”:”Length”,”normalizedValue”:”7.76 in”,”value”:”7.76 in”},{“name”:”Min. Current”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Case Material”,”normalizedValue”:”Zamak”,”value”:”Zamak”},{“name”:”For Use With”,”normalizedValue”:”Preventa XPS Safety Relays”,”value”:”Preventa XPS Safety Relays”},{“name”:”Length (Straight Wireway)”,”normalizedValue”:”7.76 in”,”value”:”7.76 in”},{“name”:”Body Material”,”normalizedValue”:”zamak”,”value”:”zamak”},{“name”:”Series”,”normalizedValue”:”XY2CE”,”value”:”XY2CE”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Cable Span – Maximum”,”normalizedValue”:”98 ft”,”value”:”98 ft”},{“name”:”Overall Depth”,”normalizedValue”:”1.57 in”,”value”:”1.57 in”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Action”,”normalizedValue”:”Maintained”,”value”:”Maintained”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”18 mo”,”value”:”18 mo”},{“name”:”Overall Width”,”normalizedValue”:”2.68 in”,”value”:”2.68 in”},{“name”:”Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Pull Force”,”normalizedValue”:”4.5 lb”,”value”:”4.5 lb”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”12, 4, 1″,”value”:”1, 12, 4″},{“name”:”Overvoltage Category”,”normalizedValue”:”class I EN/IEC 61140 || class I NF C 20-030″,”value”:”class I EN/IEC 61140 || class I NF C 20-030″},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Contact Operation”,”normalizedValue”:”slow-break”,”value”:”slow-break”},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”Cover Material”,”normalizedValue”:”Stainless Steel”,”value”:”stainless steel”},{“name”:”Local Signalling”,”normalizedValue”:”without pilot light”,”value”:”without pilot light”},{“name”:”Tightening Torque”,”normalizedValue”:”0.8-1.2 N.m”,”value”:”0.8-1.2 N.m”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14″,”value”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV EN/IEC 60947-1″,”value”:”6 kV EN/IEC 60947-1″},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NO || NC”,”value”:”(13-14)NO || (21-22)NC”},{“name”:”Compatibility Code”,”normalizedValue”:”XY2CH”,”value”:”XY2CH”},{“name”:”Distance Between Cable Supports”,”normalizedValue”:”5-5 m”,”value”:”5-5 m”},{“name”:”Positive Opening”,”normalizedValue”:”with EN/IEC 60947-5-1″,”value”:”with EN/IEC 60947-5-1″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP65 IEC 60529″,”value”:”IP65 IEC 60529″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Maximum Resistance Across Terminals”,”normalizedValue”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”,”value”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”},{“name”:”Short-Circuit Protection”,”normalizedValue”:”10 A cartridge fuse gG EN/IEC 60269″,”value”:”10 A cartridge fuse gG EN/IEC 60269″},{“name”:”Contacts Type And Composition”,”normalizedValue”:”1 NC + 1 NO”,”value”:”1 NC + 1 NO”},{“name”:”Vibration Resistance”,”normalizedValue”:”10 gn 10-150 Hz)EN/IEC 60068-2-6″,”value”:”10 gn 10-150 Hz)EN/IEC 60068-2-6″},{“name”:”Mechanical Durability”,”normalizedValue”:”800,000 cycle”,”value”:”800000 cycles”},{“name”:”Safety Level”,”normalizedValue”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″,”value”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″},{“name”:”Trigger Cable Maximum Length”,”normalizedValue”:”30 m”,”value”:”30 m”},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Housing Colour”,”normalizedValue”:”red RAL 3000″,”value”:”red RAL 3000″},{“name”:”Product Or Component Type”,”normalizedValue”:”latching emergency stop rope pull switch”,”value”:”latching emergency stop rope pull switch”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”,”value”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”Shock Resistance”,”normalizedValue”:”50 gn 11 ms EN/IEC 60068-2-27″,”value”:”50 gn 11 ms EN/IEC 60068-2-27″},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”,”value”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”},{“name”:”Cable Entry Number”,”normalizedValue”:”3 tapped entry 1/2″ NPT conduit entry”,”value”:”3 tapped entry 1/2″ NPT conduit entry”},{“name”:”Device Short Name”,”normalizedValue”:”XY2CH”,”value”:”XY2CH”},{“name”:”Product Certifications”,”normalizedValue”:”UL category NISD emergency stop devices || CSA || CCC”,”value”:”UL category NISD emergency stop devices || CSA || CCC”},{“name”:”Trigger Cable Anchor Point”,”normalizedValue”:”RH or LH side”,”value”:”RH or LH side”},{“name”:”Number Of Cables”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Multiple”,”value”:”Multiple”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Cable Pull Switch, 10A, Universal, 1NO+1NC, Telemecanique Sensors, Mfr#: XY2CH13150H7”