Description
[{“name”:”Item”,”normalizedValue”:”Emergency Cable Pull Switch”,”rank”:1,”value”:”Emergency Cable Pull Switch”},{“name”:”Switch Function”,”normalizedValue”:”Maintained”,”rank”:2,”value”:”Maintained”},{“name”:”Mounting Style”,”normalizedValue”:”Single End”,”rank”:3,”value”:”Single End”},{“name”:”AC Contact Rating”,”normalizedValue”:”3 A @ 240 V”,”rank”:4,”value”:”3 A @ 240 V”},{“name”:”Contact Form”,”normalizedValue”:”1NO/1NC”,”rank”:5,”value”:”1NO/1NC”},{“name”:”Reset”,”normalizedValue”:”Push Button”,”rank”:6,”value”:”Push Button”},{“name”:”Max. Cable Span”,”normalizedValue”:”165 ft”,”rank”:7,”value”:”165 ft”},{“name”:”Operating Force”,”normalizedValue”:””,”rank”:8,”value”:”Not Applicable”},{“name”:”NEMA Rating”,”normalizedValue”:”1, 12, 4″,”rank”:9,”value”:”1, 12, 4″},{“name”:”Indicator”,”normalizedValue”:”No Indicator”,”rank”:10,”value”:”No Indicator”},{“name”:”Switching Ability”,”normalizedValue”:”Single Cable”,”rank”:11,”value”:”Single Cable”},{“name”:”DC Contact Rating”,”normalizedValue”:”0.27 A @ 250 V”,”rank”:12,”value”:”0.27 A @ 250 V”},{“name”:”Width”,”normalizedValue”:”9.02 in”,”value”:”9.02 in”},{“name”:”Min. Current”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Case Material”,”normalizedValue”:”Zamak”,”value”:”Zamak”},{“name”:”Cable Connection Location”,”normalizedValue”:”Right”,”value”:”Right”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC”,”value”:”CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC”},{“name”:”Wiring Entry”,”normalizedValue”:”1/2 in NPT”,”value”:”1/2 in NPT”},{“name”:”Thermal Amperage”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”IP Rating”,”normalizedValue”:”IP65″,”value”:”IP65″},{“name”:”Length”,”normalizedValue”:”9 in”,”value”:”9.0 in”},{“name”:”Depth”,”normalizedValue”:”4.13 in”,”value”:”4.13 in”},{“name”:”For Use With”,”normalizedValue”:”Preventa XPS Safety Relays”,”value”:”Preventa XPS Safety Relays”},{“name”:”Length (Straight Wireway)”,”normalizedValue”:”9 in”,”value”:”9.0 in”},{“name”:”Body Material”,”normalizedValue”:”zamak”,”value”:”zamak”},{“name”:”Series”,”normalizedValue”:”XY2CE”,”value”:”XY2CE”},{“name”:”Product Certifications”,”normalizedValue”:”UL category NISD emergency stop devices || CSA || CCC”,”value”:”UL category NISD emergency stop devices || CSA || CCC”},{“name”:”Device Short Name”,”normalizedValue”:”XY2CE”,”value”:”XY2CE”},{“name”:”Trigger Cable Maximum Length”,”normalizedValue”:”70 m”,”value”:”70 m”},{“name”:”Trigger Cable Anchor Point”,”normalizedValue”:”RH side”,”value”:”RH side”},{“name”:”Local Signalling”,”normalizedValue”:”without pilot light”,”value”:”without pilot light”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”Mechanical Durability”,”normalizedValue”:”60,000 cycle”,”value”:”60000 cycles”},{“name”:”Distance Between Cable Supports”,”normalizedValue”:”5-5 m”,”value”:”5-5 m”},{“name”:”Number Of Cables”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Tightening Torque”,”normalizedValue”:”0.8-1.2 N.m”,”value”:”0.8-1.2 N.m”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”1 NC + 1 NO”,”value”:”1 NC + 1 NO”},{“name”:”Compatibility Code”,”normalizedValue”:”XY2CE”,”value”:”XY2CE”},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NO || NC”,”value”:”(13-14)NO || (21-22)NC”},{“name”:”Contact Operation”,”normalizedValue”:”slow-break”,”value”:”slow-break”},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14″,”value”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14″},{“name”:”Housing Colour”,”normalizedValue”:”red RAL 3000″,”value”:”red RAL 3000″},{“name”:”Overvoltage Category”,”normalizedValue”:”class I EN/IEC 61140 || class I NF C 20-030″,”value”:”class I EN/IEC 61140 || class I NF C 20-030″},{“name”:”Cover Material”,”normalizedValue”:”Stainless Steel”,”value”:”stainless steel”},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP66 IEC 60529″,”value”:”IP66 IEC 60529″},{“name”:”Cable Entry Number”,”normalizedValue”:”3 tapped entry 1/2\” NPT conduit entry”,”value”:”3 tapped entry 1/2\” NPT conduit entry”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”,”value”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”},{“name”:”Maximum Resistance Across Terminals”,”normalizedValue”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”,”value”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”},{“name”:”Safety Level”,”normalizedValue”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″,”value”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″},{“name”:”Vibration Resistance”,”normalizedValue”:”10 gn 10-300 Hz)EN/IEC 60068-2-6″,”value”:”10 gn 10-300 Hz)EN/IEC 60068-2-6″},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”,”value”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”Positive Opening”,”normalizedValue”:”with EN/IEC 60947-5-1″,”value”:”with EN/IEC 60947-5-1″},{“name”:”Shock Resistance”,”normalizedValue”:”50 gn 11 ms EN/IEC 60068-2-27″,”value”:”50 gn 11 ms EN/IEC 60068-2-27″},{“name”:”Short-Circuit Protection”,”normalizedValue”:”10 A cartridge fuse gG EN/IEC 60269″,”value”:”10 A cartridge fuse gG EN/IEC 60269″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV EN/IEC 60947-1″,”value”:”6 kV EN/IEC 60947-1″},{“name”:”Product Or Component Type”,”normalizedValue”:”latching emergency stop rope pull switch”,”value”:”latching emergency stop rope pull switch”},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NO || NC”,”value”:”(13-14)NO || (21-22)NC”},{“name”:”Overall Depth”,”normalizedValue”:”4.13 in”,”value”:”4.13 in”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”12, 4, 1″,”value”:”1, 12, 4″},{“name”:”Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Overall Width”,”normalizedValue”:”9.02 in”,”value”:”9.02 in”},{“name”:”Cable Span – Maximum”,”normalizedValue”:”164 ft”,”value”:”164 ft”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”18 mo”,”value”:”18 mo”},{“name”:”Action”,”normalizedValue”:”Maintained”,”value”:”Maintained”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Morocco”,”value”:”Morocco”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.