CO2 Room Sensor, LCD, 3-1/8″ H, 4″ W

$380,99

CO2 Room Sensor, Mounting Location Duct Mount, Air Quality Measurement Gas Analysis, CO2 Accuracy +/-30 ppm + 3 Percent of MV, Sensing Element Type Not Applicable, Loop Resistance 10,000 ohm, Power Required 24V DC +/-20 Percent/24V AC +/-10 Percent, Output 0 to 10V DC, 4 to 20 mA, Display Type Digital, Housing Material Polycarbonate, Minimum Operating Temperature 32 Degrees F, Maximum Operating Temperature 122 Degrees F, Compatible Building Automation Protocols BACnet MS/TP

9999 in stock

SKU: GRG610565880 Category:

Description

[{“name”:”Includes”,”normalizedValue”:”Cable Gland, Mounting Accessories”,”rank”:3,”value”:”Cable Gland, Mounting Accessories”},{“name”:”For Use With”,”normalizedValue”:”HVAC Control Systems”,”rank”:5,”value”:”HVAC Control Systems”},{“name”:”Item”,”normalizedValue”:”CO2 Room Sensor”,”rank”:8,”value”:”CO2 Room Sensor”},{“name”:”Overall Height”,”normalizedValue”:”3-3/16 in”,”value”:”3 3/16 in”},{“name”:”Application”,”normalizedValue”:”Commercial, HVAC”,”value”:”Commercial, HVAC”},{“name”:”Electrical Connection Type”,”normalizedValue”:”Hardwired”,”value”:”Hardwired”},{“name”:”Power Source”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Output”,”normalizedValue”:”0 to 10V DC, 4 to 20 mA”,”value”:”0 to 10V DC, 4 to 20 mA”},{“name”:”Probe Length”,”normalizedValue”:”6 in”,”value”:”6 in”},{“name”:”Overall Length”,”normalizedValue”:”1-3/16 in”,”value”:”1 3/16 in”},{“name”:”Overall Width”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Standards”,”normalizedValue”:”cULus Listed, UL 916, UL File E226431 CCN:PAZX”,”value”:”cULus Listed, UL 916, UL File E226431 CCN:PAZX”},{“name”:”Features”,”normalizedValue”:”Dual-Wavelength Non-Dispersive Infrared (NDIR) Co2 Sensor”,”value”:”Dual-Wavelength Non-Dispersive Infrared (NDIR) Co2 Sensor”},{“name”:”Power Required”,”normalizedValue”:”24V DC +/-20%/24V AC +/-10%”,”value”:”24V DC +/-20%/24V AC +/-10%”},{“name”:”NEMA Rating”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Minimum Storage Temperature”,”normalizedValue”:”-40 Degrees F”,”value”:”-40 Degrees F”},{“name”:”Maximum Compensated Temperature”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Relative Humidity/Dew Point Output”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Relative Humidity Range”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Process Connection Type”,”normalizedValue”:”Screw Terminal Block, 14 AWG to 22 AWG”,”value”:”Screw Terminal Block, 14 AWG to 22 AWG”},{“name”:”Wiring Entry”,”normalizedValue”:”Screw Terminal Block, 14 AWG to 22 AWG”,”value”:”Screw Terminal Block, 14 AWG to 22 AWG”},{“name”:”Maximum Sensing Temperature”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Temperature Output”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Enclosure Material”,”normalizedValue”:”Polycarbonate”,”value”:”Polycarbonate”},{“name”:”Compatible with Manufacturer Model Number”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Minimum Compensated Temperature”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Temperature Accuracy”,”normalizedValue”:”+/-30 ppm + 3%”,”value”:”+/-30 ppm + 3%”},{“name”:”IP Rating”,”normalizedValue”:”IP65″,”value”:”IP65″},{“name”:”Display Type”,”normalizedValue”:”Digital”,”value”:”Digital”},{“name”:”Response Time”,”normalizedValue”:”20 sec”,”value”:”20 sec”},{“name”:”Series”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”RH Sensor”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Power Supply”,”normalizedValue”:”Power Supply Not Included”,”value”:”Power Supply Not Included”},{“name”:”Hysteresis”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Relative Humidity Accuracy”,”normalizedValue”:”+/-0.25% of Full Scale”,”value”:”+/-0.25% of Full Scale”},{“name”:”Process Connection Size”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Display Resolution”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Repeatability”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”NIST Traceable Certificate”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”158 Degrees F”,”value”:”158 Degrees F”},{“name”:”Power Type”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Probe Diameter”,”normalizedValue”:”7/8 in”,”value”:”7/8 in”},{“name”:”Display Units”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Minimum Sensing Temperature”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Compatible with Brand”,”normalizedValue”:”Johnson Controls”,”value”:”Johnson Controls”},{“name”:”Weight”,”normalizedValue”:”0.65 lb”,”value”:”0.65 lb”},{“name”:”Compatible with Series”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Process Connection Gender”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Housing Material”,”normalizedValue”:”Polycarbonate”,”value”:”Polycarbonate”},{“name”:”Storage Temperature Range”,”normalizedValue”:”-40 to 158 deg F”,”value”:”-40 Degrees to 158 Degrees F”},{“name”:”For Use With Building Automation Systems”,”normalizedValue”:”Building Automation System Compatible”,”value”:”Building Automation System Compatible”},{“name”:”Air Quality Measurement”,”normalizedValue”:”Gas Analysis”,”value”:”Gas Analysis”},{“name”:”CO2 Accuracy”,”normalizedValue”:”+/-30 ppm + 3% of MV”,”value”:”+/-30 ppm + 3% of MV”},{“name”:”Housing Color”,”normalizedValue”:”White, Blue”,”value”:”Blue/White”},{“name”:”Wall Plate Style”,”normalizedValue”:”Flush Mount”,”value”:”Flush Mount”},{“name”:”Compatible Building Automation Protocols”,”normalizedValue”:”BACnet MS/TP”,”value”:”BACnet MS/TP”},{“name”:”Loop Resistance”,”normalizedValue”:”10,000 ohms”,”value”:”10,000 ohm”},{“name”:”Sensing Element Type”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Overall Depth”,”normalizedValue”:”1-3/16 in”,”value”:”1 3/16 in”},{“name”:”Gases Detected”,”normalizedValue”:”Carbon Dioxide”,”value”:”Carbon Dioxide”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “CO2 Room Sensor, LCD, 3-1/8″ H, 4″ W”