C-100-S2St20 Media Converter

$727,99

C-100-S2ST20 – Fast Ethernet Media Converter Module: 100BASE-TX (RJ-45) [100 m/328 ft.] to 100Base-LX 1310nm single mode (ST) [20 km/12.4 miles]

9999 in stock

SKU: GRG4396490 Category:

Description

[{“name”:”Total Number of Ports”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Form Factor”,”normalizedValue”:”External”,”value”:”External”},{“name”:”ST Port Type”,”normalizedValue”:”Duplex”,”value”:”Duplex”},{“name”:”Product Type”,”normalizedValue”:”Transceiver/Media Converter”,”value”:”Transceiver/Media Converter”},{“name”:”Environmentally Friendly”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Number of ST Ports”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Number of Network (RJ-45) Ports”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Maximum Distance Supported”,”normalizedValue”:”12.43 mi”,”value”:”12.43 Mile”},{“name”:”Product Name”,”normalizedValue”:”C-100-S2ST20 Fast Ethernet Media Converter”,”value”:”C-100-S2ST20 Fast Ethernet Media Converter”},{“name”:”Compatibility”,”normalizedValue”:”MCR1900 Media Converter Chassis”,”value”:”MCR1900 Media Converter Chassis”},{“name”:”Network (RJ-45)”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Weight (Approximate)”,”normalizedValue”:”5.29 oz”,”value”:”5.29 oz”},{“name”:”Network Technology”,”normalizedValue”:”100Base-LX, 100Base-TX”,”value”:”100Base-LX, 100Base-TX”},{“name”:”Operating Altitude”,”normalizedValue”:”Up to 3,048 meters (10,000 feet)”,”value”:”Up to 3,048 meters (10,000 feet)”},{“name”:”Link Pass Through”,”normalizedValue”:”Enabled (Default)- When the state of the receiver is changed on the 100Base-TX interface it is reflected on the 100Base-FX fiber transmitter. When the state of the receiver on the 100Base-FX interface is changed it is reflected on the 100Base-TX transmitter; When a Far-End Fault Indication is received on the fiber interface the 100Base-TX transmitter is turned off. When the Far-End Fault Indication is cleared the transmitter is turned back on; Disabled- The 100Base-TX and the 100Base-FX fiber interface operate independently. Far-End Fault indication on the 100Base-FX fiber interface has no effect on the 100Base-TX interface.”,”value”:”Enabled (Default)- When the state of the receiver is changed on the 100Base-TX interface it is reflected on the 100Base-FX fiber transmitter. When the state of the receiver on the 100Base-FX interface is changed it is reflected on the 100Base-TX transmitter; When a Far-End Fault Indication is received on the fiber interface the 100Base-TX transmitter is turned off. When the Far-End Fault Indication is cleared the transmitter is turned back on; Disabled- The 100Base-TX and the 100Base-FX fiber interface operate independently. Far-End Fault indication on the 100Base-FX fiber interface has no effect on the 100Base-TX interface.”},{“name”:”Auto-MDIX (Strap)”,”normalizedValue”:”If Auto-Negotiation (802.3u) is enabled, the media converter uses the HP Auto-MDIX method for the 100Base-TX interface. If Auto-Negotiation (802.3u) is disabled the Media converter will use the RX Energy method on the 100Base-TX interface to set the port MDI or MDIX whichever is appropriate; Enabled (Default)- Either a straight-through or crossover type cable can be used to connect the media converter to the device on the other end of the cable; Disabled- If the partner device on the other end of the cable does not have the Auto-MDIX feature a specific cable, either a straight-through or crossover will be required to ensure that the media convertor’s transmitter and the partner devices transmitter are connected to the others receiver. The Media Convertor’s 100Base-TX port is configured as MDI with this switch setting.”,”value”:”If Auto-Negotiation (802.3u) is enabled, the media converter uses the HP Auto-MDIX method for the 100Base-TX interface. If Auto-Negotiation (802.3u) is disabled the Media converter will use the RX Energy method on the 100Base-TX interface to set the port MDI or MDIX whichever is appropriate; Enabled (Default)- Either a straight-through or crossover type cable can be used to connect the media converter to the device on the other end of the cable; Disabled- If the partner device on the other end of the cable does not have the Auto-MDIX feature a specific cable, either a straight-through or crossover will be required to ensure that the media convertor’s transmitter and the partner devices transmitter are connected to the others receiver. The Media Convertor’s 100Base-TX port is configured as MDI with this switch setting.”},{“name”:”Maximum Power Consumption ( Watts )”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Immunity”,”normalizedValue”:”EN55024″,”value”:”EN55024″},{“name”:”Bit Error Rate (BER)”,”normalizedValue”:”<10-12","value":"<10-12"},{"name":"Fiber Optic Cable","normalizedValue":"Single mode dual ST Media Converters; Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron; Single Mode: 9/125 micron (ITU-T 625)","value":"Single mode dual ST Media Converters; Multimode: 62.5 / 125, 50/125, 85/125, 100/140 micron; Single Mode: 9/125 micron (ITU-T 625)"},{"name":"Operating temperature","normalizedValue":"0 C to 50 C (32 F to 122 F)","value":"0 C to 50 C (32 F to 122 F)"},{"name":"Pause","normalizedValue":"Pause should be enabled when all devices connected to the media converter support pause. Auto-Negotiation must be Enabled to use this feature; Enabled (Default)- The Media converter will advertise Pause capability during Auto-Negotiation on the 100Base-TX interface; Disabled- The Media converter will advertise that it does not have Pause capability during Auto-Negotiation on the 100Base-TX interface.","value":"Pause should be enabled when all devices connected to the media converter support pause. Auto-Negotiation must be Enabled to use this feature; Enabled (Default)- The Media converter will advertise Pause capability during Auto-Negotiation on the 100Base-TX interface; Disabled- The Media converter will advertise that it does not have Pause capability during Auto-Negotiation on the 100Base-TX interface."},{"name":"Operating Humidity","normalizedValue":"5% to 90% non-condensing","value":"5% to 90% non-condensing"},{"name":"Fiber link on / Receive activity (LKF)","normalizedValue":"This green LED is operational only when power is applied. The LED is on when the 100Base-FX link is on and flashes with a 50% duty cycle when data is received.","value":"This green LED is operational only when power is applied. The LED is on when the 100Base-FX link is on and flashes with a 50% duty cycle when data is received."},{"name":"Edge Connecter","normalizedValue":"32 pin DIN 41612 / IEC 60603-2 Type B/2 Male. Fist make, last break for ground and power","value":"32 pin DIN 41612 / IEC 60603-2 Type B/2 Male. Fist make, last break for ground and power"},{"name":"Storage temperature","normalizedValue":"minimum range of -25 C to 70 C (-13 F to 158 F)","value":"minimum range of -25 C to 70 C (-13 F to 158 F)"},{"name":"Electrical Safety","normalizedValue":"UL 60950-1","value":"UL 60950-1"},{"name":"100Base-TX","normalizedValue":"RJ45 connector, 2 pair CAT 5, EIA/TIA 568A/B or better cable","value":"RJ45 connector, 2 pair CAT 5, EIA/TIA 568A/B or better cable"},{"name":"Emissions","normalizedValue":"FCC Part 15 Class A, EN55022 Class A","value":"FCC Part 15 Class A, EN55022 Class A"},{"name":"Magnetic Isolation","normalizedValue":"1.5kv","value":"1.5kv"},{"name":"Remote Loopback","normalizedValue":"The media converter can perform a loopback on the 100Base-X fiber interface; Disabled (Default - Up); Enabled- The 100Base-X receiver is looped to the 100Base-X transmitter. The 100Base-TX transmitter is taken off the interface.","value":"The media converter can perform a loopback on the 100Base-X fiber interface; Disabled (Default - Up); Enabled- The 100Base-X receiver is looped to the 100Base-X transmitter. The 100Base-TX transmitter is taken off the interface."},{"name":"Laser Safety","normalizedValue":"EN 60825-1:2007","value":"EN 60825-1:2007"},{"name":"Heat Output ( BTU/HR )","normalizedValue":"6.8","value":"6.8"},{"name":"Copper link on / Receive activity (LKC)","normalizedValue":"This green LED is operational only when power is applied. The LED is on when the 100Base-TX link is on and flashes with a 50% duty cycle when data is received.","value":"This green LED is operational only when power is applied. The LED is on when the 100Base-TX link is on and flashes with a 50% duty cycle when data is received."},{"name":"Storage Humidity","normalizedValue":"5% to 95% non-condensing","value":"5% to 95% non-condensing"},{"name":"Power / TST","normalizedValue":"This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink when in Loopback test mode.","value":"This green LED is turned on when power is applied to the media converter. Otherwise it is off. The LED will blink when in Loopback test mode."},{"name":"Card insertion and removal","normalizedValue":"Captive thumb screws enable fast insertion and removal Can be further tighten with a screwdriver.","value":"Captive thumb screws enable fast insertion and removal. Can be further tighten with a screwdriver."},{"name":"Auto-Negotiation (802.3u)","normalizedValue":"Enabled (Default)- The media converter uses 802.3u Auto-negotiation on the 100Base-TX interface. It is set to advertise full duplex; Disabled- The media converter sets the 100Base-TX port to full duplex.","value":"Enabled (Default)- The media converter uses 802.3u Auto-negotiation on the 100Base-TX interface. It is set to advertise full duplex; Disabled- The media converter sets the 100Base-TX port to full duplex."},{"name":"Country of Origin (subject to change)","normalizedValue":"Canada","value":"Canada"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews

There are no reviews yet.

Be the first to review “C-100-S2St20 Media Converter”