Description
[{“name”:”Standards”,”normalizedValue”:”IEC 60947-7-1″,”value”:”IEC 60947-7-1″},{“name”:”Material”,”normalizedValue”:”Wemid”,”value”:”Wemid”},{“name”:”Rated cross-section”,”normalizedValue”:”2.5 mm²”,”value”:”2.5 mm²”},{“name”:”Continuous operating temp., min.”,”normalizedValue”:”-50 deg C”,”value”:”-50 °C”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Conductor size Field wiring max. (UR)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Conductor size Field wiring min. (UR)”,”normalizedValue”:”30 AWG”,”value”:”30 AWG”},{“name”:”Voltage size B (CSA)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Pollution severity”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Wire cross section max. (IECEX)”,”normalizedValue”:”4 sq mm”,”value”:”4 mm²”},{“name”:”Continuous operating temp., max.”,”normalizedValue”:”120 deg C”,”value”:”120 °C”},{“name”:”Gauge to IEC 60947-1″,”normalizedValue”:”A3″,”value”:”A3″},{“name”:”Storage temperature, min.”,”normalizedValue”:”10 deg C”,”value”:”10 °C”},{“name”:”Max. voltage (IECEX)”,”normalizedValue”:”550 V”,”value”:”550 V”},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 12″,”value”:”AWG 12″},{“name”:”Rated impulse withstand voltage”,”normalizedValue”:”8 kV”,”value”:”8 kV”},{“name”:”Stripping length”,”normalizedValue”:”10 mm”,”value”:”10 mm”},{“name”:”End cover plate required”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Number of potentials per tier”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Clamping range, min.”,”normalizedValue”:”0.05 sq mm”,”value”:”0.05 mm²”},{“name”:”Operating Temperature Range”,”normalizedValue”:”For operating temperature range see EC Design Test Certificate / IEC Ex-Certificate of Conformity”,”value”:”For operating temperature range see EC Design Test Certificate / IEC Ex-Certificate of Conformity”},{“name”:”Blade Size”,”normalizedValue”:”0.6 mm x 3.5 mm”,”value”:”0.6 x 3.5 mm”},{“name”:”Number of Levels”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Wire connection cross-section, solid core, max.”,”normalizedValue”:”4 sq mm”,”value”:”4 mm²”},{“name”:”Number of similar terminals”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Number of clamping points per level”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Certificate No. (IECEX)”,”normalizedValue”:”IECEXULD15.0008U”,”value”:”IECEXULD15.0008U”},{“name”:”UL File Number Search”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Current (IECEX)”,”normalizedValue”:”22 A”,”value”:”22 A”},{“name”:”Type of mounting”,”normalizedValue”:”Snap-on”,”value”:”Snap-on”},{“name”:”Voltage size C (UR)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Voltage size D (CSA)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Conductor size Factory wiring min. (UR)”,”normalizedValue”:”30 AWG”,”value”:”30 AWG”},{“name”:”Certificate No. (ATEX)”,”normalizedValue”:”KEMA97ATEX2521U”,”value”:”KEMA97ATEX2521U”},{“name”:”Voltage size C (CSA)”,”normalizedValue”:”600 V”,”value”:”600 V”},{“name”:”Conductor size Factory wiring max. (UR)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Current at maximum wires”,”normalizedValue”:”30 A”,”value”:”30 A”},{“name”:”Wire cross section max. (ATEX)”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 30″,”value”:”AWG 30″},{“name”:”Connection direction”,”normalizedValue”:”top”,”value”:”top”},{“name”:”Certificate No. (CSA)”,”normalizedValue”:”200,039 to 1,152,892″,”value”:”200039-1152892″},{“name”:”Storage temperature, max.”,”normalizedValue”:”40 deg C”,”value”:”40 °C”},{“name”:”Width (inches)”,”normalizedValue”:”0.201 in”,”value”:”0.201 inch”},{“name”:”Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/1, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Open sides”,”normalizedValue”:”right”,”value”:”right”},{“name”:”Current size C (UR)”,”normalizedValue”:”25 A”,”value”:”25 A”},{“name”:”PE connection”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Depth (inches)”,”normalizedValue”:”1.516 in”,”value”:”1.516 inch”},{“name”:”Version”,”normalizedValue”:”Tension-clamp connection, for plug-in cross-connector, One end without connector”,”value”:”Tension-clamp connection, for plug-in cross-connector, One end without connector”},{“name”:”Colour”,”normalizedValue”:”dark beige”,”value”:”dark beige”},{“name”:”Clamping range, max.”,”normalizedValue”:”4 sq mm”,”value”:”4 mm²”},{“name”:”Rated voltage”,”normalizedValue”:”800 V”,”value”:”800 V”},{“name”:”Current size C (CSA)”,”normalizedValue”:”27 A”,”value”:”27 A”},{“name”:”Wire connection cross-section, finely stranded, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Certificate No. (UR)”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Rail”,”normalizedValue”:”TS 35″,”value”:”TS 35″},{“name”:”Approvals”,”normalizedValue”:”CE, CSA, CURUSEX, DEMKOATEX, DNV GL, EAC, IECEXULD, INMETRO, KEMAATEX, KEMAKEUR, LLOYDSREG, MARITREG, RINA, UR”,”value”:”CE, CSA, CURUSEX, DEMKOATEX, DNV GL, EAC, IECEXULD, INMETRO, KEMAATEX, KEMAKEUR, LLOYDSREG, MARITREG, RINA, UR”},{“name”:”Wire connection cross-section, solid core, min.”,”normalizedValue”:”0.5 mm²”,”value”:”0.5 mm²”},{“name”:”Rated current”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Depth including DIN rail”,”normalizedValue”:”39.5 mm”,”value”:”39.5 mm”},{“name”:”Wire cross section min. (CSA)”,”normalizedValue”:”26 AWG”,”value”:”26 AWG”},{“name”:”Current size B (CSA)”,”normalizedValue”:”27 A”,”value”:”27 A”},{“name”:”Height (inches)”,”normalizedValue”:”2.343 in”,”value”:”2.343 inch”},{“name”:”Volume resistance according to IEC 60947-7-x”,”normalizedValue”:”1.33 milliohm”,”value”:”1.33 mΩ”},{“name”:”Current (ATEX)”,”normalizedValue”:”21 A”,”value”:”21 A”},{“name”:”Marking EN 60079-7″,”normalizedValue”:”Ex eb II C Gb”,”value”:”Ex eb II C Gb”},{“name”:”Current size D (CSA)”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Storage temperature”,”normalizedValue”:”10 deg C”,”value”:”10°C…40°C”},{“name”:”Max. voltage (ATEX)”,”normalizedValue”:”550 V”,”value”:”550 V”},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Power loss in accordance with IEC 60947-7-x”,”normalizedValue”:”0.77 W”,”value”:”0.77 W”},{“name”:”Wire connection cross section, finely stranded, max.”,”normalizedValue”:”4 sq mm”,”value”:”4 mm²”},{“name”:”Number of connections”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Wire cross section max. (CSA)”,”normalizedValue”:”12 AWG”,”value”:”12 AWG”},{“name”:”Type of connection”,”normalizedValue”:”Tension-clamp connection”,”value”:”Tension-clamp connection”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.