Booster Pump, 2 hp, 208 to 240/480V AC, 3 Phase, 3/4 in NPT Inlet Size, 14 Stage

$1832,40

Booster Pump, Phase Three, Pump Housing Material Cast Iron, Motor Enclosure Open Dripproof, Horsepower 2 hp, Nameplate Voltage 208-230/460V AC, Flow Rate @ 10 psi 27.6 gpm, Flow Rate @ 20 psi 27 gpm, Flow Rate @ 30 psi 26 gpm, Flow Rate @ 40 psi 25.7 gpm, Flow Rate @ 50 psi 25 gpm, Flow Rate @ 60 psi 24.2 gpm, Flow Rate @ 70 psi 27.5 gpm, Flow Rate @ 80 psi 25 gpm, Flow Rate @ 90 psi 22 gpm, Flow Rate @ 100 psi 20.8 gpm, Flow Rate @ 120 psi 18.7 gpm, Shut Off Pressure (Maximum) 190 psi

9999 in stock

SKU: GRG0385500 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Booster Pump”,”rank”:1,”value”:”Booster Pump”},{“name”:”Booster Pump Type”,”normalizedValue”:”Multi-Stage Booster Pump”,”rank”:1,”value”:”Multi-Stage Booster Pump”},{“name”:”HP – Pumps”,”normalizedValue”:”2 hp”,”rank”:2,”value”:”2 hp”},{“name”:”Voltage – Pumps”,”normalizedValue”:”208 to 240/480V AC”,”rank”:3,”value”:”208 to 240/480V AC”},{“name”:”Phase – Pumps”,”normalizedValue”:”3″,”rank”:4,”value”:”3″},{“name”:”Inlet Size – Pumps”,”normalizedValue”:”3/4 in NPT”,”rank”:5,”value”:”3/4 in NPT”},{“name”:”Outlet Size – Pumps”,”normalizedValue”:”3/4 in NPT”,”rank”:6,”value”:”3/4 in NPT”},{“name”:”Number of Stages – Pumps”,”normalizedValue”:”14″,”rank”:7,”value”:”14″},{“name”:”Max. Pressure – Pumps”,”normalizedValue”:”190 psi”,”rank”:8,”value”:”190 psi”},{“name”:”Housing Material – Pumps”,”normalizedValue”:”Cast Iron”,”rank”:9,”value”:”Cast Iron”},{“name”:”Motor Enclosure – Pumps”,”normalizedValue”:”Open Dripproof”,”rank”:10,”value”:”Open Dripproof”},{“name”:”Width”,”normalizedValue”:”6-1/2 in”,”value”:”6 1/2 in”},{“name”:”Inlet”,”normalizedValue”:”3/4 in”,”value”:”3/4\” FNPT”},{“name”:”Motor Type”,”normalizedValue”:”Capacitor-Start”,”value”:”Capacitor-Start”},{“name”:”Duty”,”normalizedValue”:”Continuous”,”value”:”Continuous”},{“name”:”Bearing Type”,”normalizedValue”:”Ball”,”value”:”Ball”},{“name”:”GPM @ 10 PSI”,”normalizedValue”:”56″,”value”:”56″},{“name”:”Frame”,”normalizedValue”:”56J”,”value”:”56J”},{“name”:”Hz”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Pump Mounting Position”,”normalizedValue”:”Horizontal or Vertical with Inlet Down”,”value”:”Horizontal or Vertical with Inlet Down”},{“name”:”Max. Pressure”,”normalizedValue”:”190 psi”,”value”:”190 psi”},{“name”:”Housing Material”,”normalizedValue”:”Cast iron”,”value”:”Cast iron”},{“name”:”Phase”,”normalizedValue”:”Three”,”value”:”Three”},{“name”:”HP”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Impeller Type”,”normalizedValue”:”Closed”,”value”:”Closed”},{“name”:”Impeller Material”,”normalizedValue”:”Noryl”,”value”:”Noryl”},{“name”:”Outlet”,”normalizedValue”:”3/4\” FNPT”,”value”:”3/4\” FNPT”},{“name”:”Seal Material”,”normalizedValue”:”Buna-N, Carbon, Ceramic, Stainless Steel”,”value”:”Buna-N, Carbon, Ceramic, Stainless Steel”},{“name”:”Voltage”,”normalizedValue”:”208-230/460″,”value”:”208-230/460″},{“name”:”Stages”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Motor Enclosure”,”normalizedValue”:”Open Dripproof”,”value”:”Open Dripproof (ODP)”},{“name”:”Max. Liquid Temp.”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Suction Lift”,”normalizedValue”:”0 ft”,”value”:”0 ft”},{“name”:”Height”,”normalizedValue”:”9 in”,”value”:”9 in”},{“name”:”Motor Ambient Temp. Rating”,”normalizedValue”:”65 Degrees C”,”value”:”65 Degrees C”},{“name”:”Pressure Boost (Maximum)”,”normalizedValue”:”216 psi”,”value”:”216 psi”},{“name”:”Intake Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Impeller Design”,”normalizedValue”:”Closed”,”value”:”Closed”},{“name”:”Suction Lift (Maximum)”,”normalizedValue”:”0 ft”,”value”:”0 ft”},{“name”:”Compatible with Media Type”,”normalizedValue”:”Clear Water Only”,”value”:”Clear Water Only”},{“name”:”Pump Housing Material”,”normalizedValue”:”Cast Iron”,”value”:”Cast Iron”},{“name”:”Flow Rate @ 120 psi”,”normalizedValue”:”18.7 gpm”,”value”:”18.7 gpm”},{“name”:”Minimum Media Temperature”,”normalizedValue”:”34 deg F”,”value”:”34 Degrees F”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”1 yr”,”value”:”1 yr”},{“name”:”Flow Rate @ 40 psi”,”normalizedValue”:”25.7 gpm”,”value”:”25.7 gpm”},{“name”:”Motor Frame Designation”,”normalizedValue”:”56J NEMA”,”value”:”56J NEMA”},{“name”:”Flow Rate @ 60 psi”,”normalizedValue”:”24.2 gpm”,”value”:”24.2 gpm”},{“name”:”Series”,”normalizedValue”:”PB”,”value”:”PB”},{“name”:”Duty Cycle”,”normalizedValue”:”Continuous”,”value”:”Continuous”},{“name”:”Number of Stages”,”normalizedValue”:”14″,”value”:”14″},{“name”:”Nameplate Voltage”,”normalizedValue”:”208-230/460V AC”,”value”:”208-230/460V AC”},{“name”:”Intake Size”,”normalizedValue”:”3/4 in”,”value”:”3/4 in”},{“name”:”Motor Ambient Temperature (Maximum)”,”normalizedValue”:”149 deg F”,”value”:”149 Degrees F”},{“name”:”Horsepower”,”normalizedValue”:”2″,”value”:”2 hp”},{“name”:”Motor Ambient Temperature (Minimum)”,”normalizedValue”:”65 deg F”,”value”:”65 Degrees F”},{“name”:”Shut Off Pressure (Maximum)”,”normalizedValue”:”190 psi”,”value”:”190 psi”},{“name”:”Flow Rate @ 15 psi”,”normalizedValue”:”25 gpm”,”value”:”25 gpm”},{“name”:”Flow Rate @ 80 psi”,”normalizedValue”:”25 gpm”,”value”:”25 gpm”},{“name”:”Pumping Application”,”normalizedValue”:”Booster Service, General Purpose, Jockey Pump, Pressure Cleaning, Reverse Osmosis, Spray or Mist Systems, Water Circulation”,”value”:”Booster Service, General Purpose, Jockey Pump, Pressure Cleaning, Reverse Osmosis, Spray or Mist Systems, Water Circulation”},{“name”:”Compatible Intake Pipe Size”,”normalizedValue”:”3/4 in”,”value”:”3/4 in”},{“name”:”Flow Rate @ 50 psi”,”normalizedValue”:”25 gpm”,”value”:”25 gpm”},{“name”:”Flow Rate @ 180 psi”,”normalizedValue”:”7.7 gpm”,”value”:”7.7 gpm”},{“name”:”Flow Rate @ 10 psi”,”normalizedValue”:”27.6 gpm”,”value”:”27.6 gpm”},{“name”:”Maximum Flow Rate”,”normalizedValue”:”41.5 gpm”,”value”:”41.5 gpm”},{“name”:”Flow Rate @ 30 psi”,”normalizedValue”:”26 gpm”,”value”:”26 gpm”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Flow Rate @ 140 psi”,”normalizedValue”:”16.2 gpm”,”value”:”16.2 gpm”},{“name”:”Flow Rate @ 20 psi”,”normalizedValue”:”27 gpm”,”value”:”27 gpm”},{“name”:”Overall Height”,”normalizedValue”:”9 in”,”value”:”9 in”},{“name”:”Overall Width”,”normalizedValue”:”6-1/2 in”,”value”:”6.5 in”},{“name”:”Flow Rate @ 70 psi”,”normalizedValue”:”27.5 gpm”,”value”:”27.5 gpm”},{“name”:”Flow Rate @ 90 psi”,”normalizedValue”:”22 gpm”,”value”:”22 gpm”},{“name”:”Discharge Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Priming”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Flow Rate @ 100 psi”,”normalizedValue”:”20.8 gpm”,”value”:”20.8 gpm”},{“name”:”For Use With Potable Systems”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Standards”,”normalizedValue”:”CSAus Certified”,”value”:”CSAus Certified”},{“name”:”Maximum Media Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Maximum RPM”,”normalizedValue”:”3,450 rpm”,”value”:”3,450 RPM”},{“name”:”Mounting Orientation”,”normalizedValue”:”Horizontal”,”value”:”Horizontal”},{“name”:”Compatible Discharge Pipe Size”,”normalizedValue”:”3/4 in”,”value”:”3/4 in”},{“name”:”Minimum Flow Rate”,”normalizedValue”:”1.5 gpm”,”value”:”1.5 gpm”},{“name”:”Flow Rate @ 160 psi”,”normalizedValue”:”13 gpm”,”value”:”13 gpm”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Booster Pump, 2 hp, 208 to 240/480V AC, 3 Phase, 3/4 in NPT Inlet Size, 14 Stage”