Description
[{“name”:”Number of Poles”,”normalizedValue”:”10″,”rank”:9,”value”:”10″},{“name”:”Flexible, max. H05(07) V-K”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Solid, min. H05(07) V-U”,”normalizedValue”:”0.5 sq mm”,”value”:”0.5 mm²”},{“name”:”L1 in inches”,”normalizedValue”:”1.8 in”,”value”:”1.8 inch”},{“name”:”Operating temperature, min.”,”normalizedValue”:”-50 °C”,”value”:”-50 °C”},{“name”:”Rated impulse voltage for surge voltage class/ pollution degree II/2″,”normalizedValue”:”4 kV”,”value”:”4 kV”},{“name”:”Rated voltage (Use group D / UL 1059)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Temperature range, installation, max.”,”normalizedValue”:”120 deg C”,”value”:”120 °C”},{“name”:”Certificate No. (cURus)”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”VPE height”,”normalizedValue”:”0 m”,”value”:”0 m”},{“name”:”w. wire end ferrule, DIN 46228 pt 1, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Flexible, min. H05(07) V-K”,”normalizedValue”:”0.25 sq mm”,”value”:”0.25 mm²”},{“name”:”Depth (inches)”,”normalizedValue”:”0.756 in”,”value”:”0.756 inch”},{“name”:”Rated impulse voltage for surge voltage class/ contamination degree III/3″,”normalizedValue”:”4 kV”,”value”:”4 kV”},{“name”:”Touch-safe protection acc. to DIN VDE 0470″,”normalizedValue”:”IP 20″,”value”:”IP 20″},{“name”:”Rated current (Use group B / UL 1059)”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Solder eyelet hole diameter (D)”,”normalizedValue”:”1.1 mm”,”value”:”1.1 mm”},{“name”:”Institute (CSA)”,”normalizedValue”:”CSA”,”value”:”CSA”},{“name”:”Plug gauge in accordance with EN 60999 a x b; ø”,”normalizedValue”:”2.4 mm x 1.5 mm”,”value”:”2.4 mm x 1.5 mm”},{“name”:”Solder pin length (l)”,”normalizedValue”:”3.5 mm”,”value”:”3.5 mm”},{“name”:”Storage temperature, max.”,”normalizedValue”:”55 deg C”,”value”:”55 °C”},{“name”:”Operating temperature, max.”,”normalizedValue”:”120 deg C”,”value”:”120 °C”},{“name”:”Rated voltage (Use group B / CSA)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Colour of operational elements”,”normalizedValue”:”black”,”value”:”black”},{“name”:”Contact surface”,”normalizedValue”:”tinned”,”value”:”tinned”},{“name”:”Temperature range, installation, min.”,”normalizedValue”:”-25 deg C”,”value”:”-25 °C”},{“name”:”w. wire end ferrule, DIN 46228 pt 1, min.”,”normalizedValue”:”0.25 sq mm”,”value”:”0.25 mm²”},{“name”:”Width (inches)”,”normalizedValue”:”2.103 in”,”value”:”2.103 inch”},{“name”:”Max. clamping range”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Material of operational elements”,”normalizedValue”:”PBT”,”value”:”PBT”},{“name”:”Colour chart (similar)”,”normalizedValue”:”RAL 2000″,”value”:”RAL 2000″},{“name”:”Number of Rows”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Max. adjacent poles per row”,”normalizedValue”:”24″,”value”:”24″},{“name”:”Rated current, min. number of poles (Tu=40°C)”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Solid, max. H05(07) V-U”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Touch-safe protection acc. to DIN VDE 57 106″,”normalizedValue”:”Safe from finger touch”,”value”:”Safe from finger touch”},{“name”:”w. plastic collar ferrule, DIN 46228 pt 4, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”w. plastic collar ferrule, DIN 46228 pt 4, min.”,”normalizedValue”:”0.25 sq mm”,”value”:”0.25 mm²”},{“name”:”Rated impulse voltage for surge voltage class/ pollution degree III/2″,”normalizedValue”:”4 kV”,”value”:”4 kV”},{“name”:”Tinning type”,”normalizedValue”:”matt”,”value”:”matt”},{“name”:”Rated current, max. number of poles (Tu=20°C)”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Rated voltage for surge voltage class / pollution degree III/3″,”normalizedValue”:”250 V”,”value”:”250 V”},{“name”:”Wire cross-section, AWG, max.”,”normalizedValue”:”AWG 12″,”value”:”AWG 12″},{“name”:”Approvals”,”normalizedValue”:”CSA, cURus, EAC”,”value”:”CSA, cURus, EAC”},{“name”:”VPE width”,”normalizedValue”:”0 m”,”value”:”0 m”},{“name”:”Coating”,”normalizedValue”:”4-6 μm SN”,”value”:”4-6 μm SN”},{“name”:”Rated voltage for surge voltage class / pollution degree II/2″,”normalizedValue”:”400 V”,”value”:”400 V”},{“name”:”Institute (cURus)”,”normalizedValue”:”cURus”,”value”:”cURus”},{“name”:”Screwdriver blade standard”,”normalizedValue”:”DIN 5264″,”value”:”DIN 5264″},{“name”:”VPE length”,”normalizedValue”:”0 m”,”value”:”0 m”},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Rated current, max. number of poles (Tu=40°C)”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Solder pin dimensions”,”normalizedValue”:”d = 0.8 mm”,”value”:”d = 0.8 mm”},{“name”:”Number of solder pins per pole”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 24″,”value”:”AWG 24″},{“name”:”Layer structure of solder connection”,”normalizedValue”:”4-6µm Sn matt”,”value”:”4-6µm Sn matt”},{“name”:”tested acc. to standard”,”normalizedValue”:”IEC 60664-1, IEC 61984″,”value”:”IEC 60664-1, IEC 61984″},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 12″,”value”:”AWG 12″},{“name”:”Wire cross-section, AWG, min.”,”normalizedValue”:”AWG 24″,”value”:”AWG 24″},{“name”:”Rated current (Use group D / CSA)”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Rated current, min. number of poles (Tu=20°C)”,”normalizedValue”:”24 A”,”value”:”24 A”},{“name”:”Height (inches)”,”normalizedValue”:”0.72 in”,”value”:”0.72 inch”},{“name”:”Rated current (Use group B / CSA)”,”normalizedValue”:”20 A”,”value”:”20 A”},{“name”:”Colour”,”normalizedValue”:”orange”,”value”:”orange”},{“name”:”Short-time withstand current resistance”,”normalizedValue”:”3 x 1s with 120 A”,”value”:”3 x 1s with 120 A”},{“name”:”Rated voltage (Use group D / CSA)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Conductor outlet direction”,”normalizedValue”:”90°”,”value”:”90°”},{“name”:”Stripping length”,”normalizedValue”:”10 mm”,”value”:”10 mm”},{“name”:”Storage temperature, min.”,”normalizedValue”:”-25 °C”,”value”:”-25 °C”},{“name”:”Wire connection method”,”normalizedValue”:”PUSH IN”,”value”:”PUSH IN”},{“name”:”Mounting onto the PCB”,”normalizedValue”:”THT solder connection”,”value”:”THT solder connection”},{“name”:”Contact material”,”normalizedValue”:”CuSn”,”value”:”CuSn”},{“name”:”Certificate No. (CSA)”,”normalizedValue”:”20,039 to 1,815,154″,”value”:”20039-1815154″},{“name”:”Max. relative humidity during storage”,”normalizedValue”:”80 %”,”value”:”80 %”},{“name”:”Comparative Tracking Index (CTI)”,”normalizedValue”:”≥600″,”value”:”≥600″},{“name”:”Height of lowest version”,”normalizedValue”:”14.8 mm”,”value”:”14.8 mm”},{“name”:”UL File Number Search”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Rated voltage (Use group B / UL 1059)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Screwdriver blade”,”normalizedValue”:”0.6 x 3.5″,”value”:”0.6 x 3.5″},{“name”:”Insulation strength”,”normalizedValue”:”≥108 Ω”,”value”:”≥108 Ω”},{“name”:”Insulating material”,”normalizedValue”:”Wemid”,”value”:”Wemid (PA)”},{“name”:”Clamping range, max.”,”normalizedValue”:”2.5 sq mm”,”value”:”2.5 mm²”},{“name”:”Rated current (Use group D / UL 1059)”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Solder eyelet hole diameter tolerance (D)”,”normalizedValue”:”+ 0,1 mm”,”value”:”+ 0,1 mm”},{“name”:”Clamping range, min.”,”normalizedValue”:”0.12 sq mm”,”value”:”0.12 mm²”},{“name”:”Rated voltage for surge voltage class / pollution degree III/2″,”normalizedValue”:”320 V”,”value”:”320 V”},{“name”:”Pitch in inches (P)”,”normalizedValue”:”0.2 in”,”value”:”0.2 inch”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.