Description
[{“name”:”Number of Poles”,”normalizedValue”:”5″,”value”:”5″},{“name”:”Layer structure of plug contact”,”normalizedValue”:”4-8µm Sn”,”value”:”4-8µm Sn”},{“name”:”Colour chart (similar)”,”normalizedValue”:”RAL 2000″,”value”:”RAL 2000″},{“name”:”Rated impulse voltage for surge voltage class/ pollution degree II/2″,”normalizedValue”:”2.5 kV”,”value”:”2.5 kV”},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Touch-safe protection acc. to DIN VDE 57 106″,”normalizedValue”:”Safe from finger touch”,”value”:”Safe from finger touch”},{“name”:”Type of connection”,”normalizedValue”:”Field connection”,”value”:”Field connection”},{“name”:”Rated cross-section”,”normalizedValue”:”1 mm²”,”value”:”1 mm²”},{“name”:”Contact material”,”normalizedValue”:”Copper alloy”,”value”:”Copper alloy”},{“name”:”Clamping range, max.”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Rated voltage for surge voltage class / pollution degree III/2″,”normalizedValue”:”160 V”,”value”:”160 V”},{“name”:”Rated current, min. number of poles (Tu=20°C)”,”normalizedValue”:”17.5 A”,”value”:”17.5 A”},{“name”:”Wire connection method”,”normalizedValue”:”Clamping yoke connection”,”value”:”Clamping yoke connection”},{“name”:”Comparative Tracking Index (CTI)”,”normalizedValue”:”≥550″,”value”:”≥550″},{“name”:”Temperature range, installation, min.”,”normalizedValue”:”-25 deg C”,”value”:”-25 °C”},{“name”:”Institute (CSA)”,”normalizedValue”:”CSA”,”value”:”CSA”},{“name”:”w. plastic collar ferrule, DIN 46228 pt 4, max.”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Rated voltage (Use group B / UL 1059)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Contact surface”,”normalizedValue”:”tinned”,”value”:”tinned”},{“name”:”L1 in inches”,”normalizedValue”:”0.6 in”,”value”:”0.6 inch”},{“name”:”Insulating material”,”normalizedValue”:”PA 66 GF 30″,”value”:”PA 66 GF 30″},{“name”:”Tightening torque for screw flange, max.”,”normalizedValue”:”0.3 N-m”,”value”:”0.3 Nm”},{“name”:”Pulling force/pole, max.”,”normalizedValue”:”5 N”,”value”:”5 N”},{“name”:”Pitch in inches (P)”,”normalizedValue”:”0.15 in”,”value”:”0.15 inch”},{“name”:”Max. clamping range”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Rated voltage (Use group D / UL 1059)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Rated impulse voltage for surge voltage class/ contamination degree III/3″,”normalizedValue”:”2.5 kV”,”value”:”2.5 kV”},{“name”:”Plugging cycles”,”normalizedValue”:”25″,”value”:”25″},{“name”:”Temperature range, installation, max.”,”normalizedValue”:”120 deg C”,”value”:”120 °C”},{“name”:”Stripping length”,”normalizedValue”:”7 mm”,”value”:”7 mm”},{“name”:”Plugging force/pole, max.”,”normalizedValue”:”8 N”,”value”:”8 N”},{“name”:”Short-time withstand current resistance”,”normalizedValue”:”3 x 1s with 76 A”,”value”:”3 x 1s with 76 A”},{“name”:”Rated voltage (Use group B / CSA)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Conductor outlet direction”,”normalizedValue”:”180°”,”value”:”180°”},{“name”:”Rated current, max. number of poles (Tu=20°C)”,”normalizedValue”:”17.1 A”,”value”:”17.1 A”},{“name”:”tested acc. to standard”,”normalizedValue”:”IEC 60664-1, IEC 61984″,”value”:”IEC 60664-1, IEC 61984″},{“name”:”Tightening torque, max.”,”normalizedValue”:”0.25 N-m”,”value”:”0.25 Nm”},{“name”:”Rated current (Use group D / UL 1059)”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Certificate No. (cURus)”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Rated current, min. number of poles (Tu=40°C)”,”normalizedValue”:”17.5 A”,”value”:”17.5 A”},{“name”:”Screwdriver blade standard”,”normalizedValue”:”DIN 5264-A”,”value”:”DIN 5264-A”},{“name”:”GWFI”,”normalizedValue”:”960 °C”,”value”:”960 °C”},{“name”:”Solid, min. H05(07) V-U”,”normalizedValue”:”0.2 sq mm”,”value”:”0.2 mm²”},{“name”:”Rated voltage for surge voltage class / pollution degree III/3″,”normalizedValue”:”160 V”,”value”:”160 V”},{“name”:”VPE length”,”normalizedValue”:”25 mm”,”value”:”25 mm”},{“name”:”Rated current (Use group B / UL 1059)”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Rated current (Use group B / CSA)”,”normalizedValue”:”11 A”,”value”:”11 A”},{“name”:”Volume resistance”,”normalizedValue”:”6 milliohm”,”value”:”6.00 mΩ”},{“name”:”Rated voltage for surge voltage class / pollution degree II/2″,”normalizedValue”:”320 V”,”value”:”320 V”},{“name”:”Tightening torque, min.”,”normalizedValue”:”0.2 N-m”,”value”:”0.2 Nm”},{“name”:”Wire cross-section, AWG, min.”,”normalizedValue”:”AWG 28″,”value”:”AWG 28″},{“name”:”Colour”,”normalizedValue”:”orange”,”value”:”orange”},{“name”:”Number of Rows”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Certificate No. (CSA)”,”normalizedValue”:”200,039 to 1,121,690″,”value”:”200039-1121690″},{“name”:”Max. relative humidity during storage”,”normalizedValue”:”80 %”,”value”:”80 %”},{“name”:”Rated voltage (Use group C / CSA)”,”normalizedValue”:”50 V”,”value”:”50 V”},{“name”:”Depth (inches)”,”normalizedValue”:”0.724 in”,”value”:”0.724 inch”},{“name”:”Solid, max. H05(07) V-U”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Flexible, max. H05(07) V-K”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Tightening torque for screw flange, min.”,”normalizedValue”:”0.2 Nm”,”value”:”0.2 Nm”},{“name”:”Height (inches)”,”normalizedValue”:”0.437 in”,”value”:”0.437 inch”},{“name”:”Wire cross-section, AWG, max.”,”normalizedValue”:”AWG 16″,”value”:”AWG 16″},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 16″,”value”:”AWG 16″},{“name”:”Approvals”,”normalizedValue”:”CSA, EAC, cURus”,”value”:”CSA, cURus, EAC”},{“name”:”Rated current, max. number of poles (Tu=40°C)”,”normalizedValue”:”15.2 A”,”value”:”15.2 A”},{“name”:”Pin series quantity”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Institute (cURus)”,”normalizedValue”:”cURus”,”value”:”cURus”},{“name”:”Clamping range, min.”,”normalizedValue”:”0.08 sq mm”,”value”:”0.08 mm²”},{“name”:”Storage temperature, min.”,”normalizedValue”:”-25 °C”,”value”:”-25 °C”},{“name”:”VPE width”,”normalizedValue”:”115 mm”,”value”:”115 mm”},{“name”:”Rated current (Use group C / CSA)”,”normalizedValue”:”11 A”,”value”:”11 A”},{“name”:”Operating temperature, max.”,”normalizedValue”:”120 deg C”,”value”:”120 °C”},{“name”:”w. wire end ferrule, DIN 46228 pt 1, min.”,”normalizedValue”:”0.2 sq mm”,”value”:”0.2 mm²”},{“name”:”Insulating material group”,”normalizedValue”:”II”,”value”:”II”},{“name”:”w. wire end ferrule, DIN 46228 pt 1, max.”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 28″,”value”:”AWG 28″},{“name”:”Insulation strength”,”normalizedValue”:”≥108 Ω”,”value”:”≥108 Ω”},{“name”:”Rated impulse voltage for surge voltage class/ pollution degree III/2″,”normalizedValue”:”2.5 kV”,”value”:”2.5 kV”},{“name”:”Plug gauge in accordance with EN 60999 a x b; ø”,”normalizedValue”:”2.4 mm x 1.5 mm ; 2.4 mm”,”value”:”2.4 mm x 1.5 mm ; 2.4 mm”},{“name”:”VPE height”,”normalizedValue”:”160 mm”,”value”:”160 mm”},{“name”:”Flexible, min. H05(07) V-K”,”normalizedValue”:”0.2 sq mm”,”value”:”0.2 mm²”},{“name”:”Operating temperature, min.”,”normalizedValue”:”-50 °C”,”value”:”-50 °C”},{“name”:”Storage temperature, max.”,”normalizedValue”:”55 °C”,”value”:”55 °C”},{“name”:”Screwdriver blade”,”normalizedValue”:”0.4 x 2.5″,”value”:”0.4 x 2.5″},{“name”:”Clamping screw”,”normalizedValue”:”M 2″,”value”:”M 2″},{“name”:”Touch-safe protection acc. to DIN VDE 0470″,”normalizedValue”:”IP 20″,”value”:”IP 20″},{“name”:”w. plastic collar ferrule, DIN 46228 pt 4, min.”,”normalizedValue”:”0.2 sq mm”,”value”:”0.2 mm²”},{“name”:”UL File Number Search”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.