Description
[{“name”:”Type”,”normalizedValue”:”BCF 3.81/05/180LR SN OR BX”,”value”:”BCF 3.81/05/180LR SN OR BX”},{“name”:”Stripping length”,”normalizedValue”:”9 mm”,”value”:”9 mm”},{“name”:”Operating temperature, min.”,”normalizedValue”:”-50 deg C”,”value”:”-50 °C”},{“name”:”Short-time withstand current resistance”,”normalizedValue”:”3 x 1s with 76 A”,”value”:”3 x 1s with 76 A”},{“name”:”Rated cross-section”,”normalizedValue”:”1 mm²”,”value”:”1 mm²”},{“name”:”Number of Rows”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Touch-safe protection acc. to DIN VDE 0470″,”normalizedValue”:”IP 20″,”value”:”IP 20″},{“name”:”Product data”,”normalizedValue”:”UL: 300 V / 10 A / AWG 26 – AWG 16, IEC: 320 V / 17.5 A / 0.14 – 1.5 mm²”,”value”:”UL: 300 V / 10 A / AWG 26 – AWG 16, IEC: 320 V / 17.5 A / 0.14 – 1.5 mm²”},{“name”:”Flexible, max. H05(07) V-K”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Wire cross-section, AWG, min.”,”normalizedValue”:”AWG 26″,”value”:”AWG 26″},{“name”:”Clamping range, rated connection, max.”,”normalizedValue”:”1.5 mm²”,”value”:”1.5 mm²”},{“name”:”Touch-safe protection acc. to DIN VDE 57 106″,”normalizedValue”:”Safe from finger touch”,”value”:”Safe from finger touch”},{“name”:”Type of connection”,”normalizedValue”:”Field connection”,”value”:”Field connection”},{“name”:”Approvals”,”normalizedValue”:”EAC, CSA, cURus”,”value”:”EAC, CSA, CURUS”},{“name”:”Rated voltage (Use group C)”,”normalizedValue”:”50 V”,”value”:”50 V”},{“name”:”Storage temperature, min.”,”normalizedValue”:”-25 °C”,”value”:”-25 °C”},{“name”:”Screwdriver blade”,”normalizedValue”:”0.4 x 2.5″,”value”:”0.4 x 2.5″},{“name”:”UL File Number Search”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”UL 94 flammability rating”,”normalizedValue”:”V-0″,”value”:”V-0″},{“name”:”Insulating material group”,”normalizedValue”:”II”,”value”:”II”},{“name”:”Solid, min. H05(07) V-U”,”normalizedValue”:”0.14 sq mm”,”value”:”0.14 mm²”},{“name”:”Rated current, min. no. of poles (Ta = 20°C)”,”normalizedValue”:”17.5 A”,”value”:”17.5 A”},{“name”:”Temperature range, installation, min.”,”normalizedValue”:”-25 deg C”,”value”:”-25 °C”},{“name”:”Max. relative humidity during storage”,”normalizedValue”:”80 %”,”value”:”80 %”},{“name”:”Conductor outlet direction”,”normalizedValue”:”180°”,”value”:”180°”},{“name”:”Rated current (use group C)”,”normalizedValue”:”11 A”,”value”:”11 A”},{“name”:”Rated current (use group D)”,”normalizedValue”:”11 A, 10 A”,”value”:”11 A, 10 A”},{“name”:”CTI”,”normalizedValue”:”≥550″,”value”:”≥550″},{“name”:”Screwdriver blade standard”,”normalizedValue”:”DIN 5264″,”value”:”DIN 5264″},{“name”:”Rated impulse voltage for surge voltage class/ contamination degree III/3″,”normalizedValue”:”2.5 kV”,”value”:”2.5 kV”},{“name”:”Rated current, max. no. of poles (Ta = 40°C)”,”normalizedValue”:”16.3 A”,”value”:”16.3 A”},{“name”:”Solid, max. H05(07) V-U”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Plug gauge acc. to EN 60999 a x b; Ø”,”normalizedValue”:”2.4 mm x 1.5 mm; 1.9mm”,”value”:”2.4 mm x 1.5 mm; 1.9mm”},{“name”:”Rated voltage for surge voltage class / pollution degree III/2″,”normalizedValue”:”160 V”,”value”:”160 V”},{“name”:”Insulating material”,”normalizedValue”:”PA GF”,”value”:”PA GF”},{“name”:”w. plastic collar ferrule, DIN 46228 pt 4, min.”,”normalizedValue”:”0.25 sq mm”,”value”:”0.25 mm²”},{“name”:”Pitch in inches (P)”,”normalizedValue”:”0.15 in”,”value”:”0.15 inch”},{“name”:”Rated impulse voltage for surge voltage class/ pollution degree III/2″,”normalizedValue”:”2.5 kV”,”value”:”2.5 kV”},{“name”:”Rated current, min. no. of poles (Ta = 40°C)”,”normalizedValue”:”17.5 A”,”value”:”17.5 A”},{“name”:”tested acc. to standard”,”normalizedValue”:”IEC 60664-1, IEC 61984″,”value”:”IEC 60664-1, IEC 61984″},{“name”:”Rated voltage for surge voltage class / pollution degree III/3″,”normalizedValue”:”160 V”,”value”:”160 V”},{“name”:”Clamping range, rated connection, min.”,”normalizedValue”:”0.14 mm²”,”value”:”0.14 mm²”},{“name”:”Rated impulse voltage for surge voltage class/ pollution degree II/2″,”normalizedValue”:”2.5 kV”,”value”:”2.5 kV”},{“name”:”Rated current (use group B)”,”normalizedValue”:”11 A, 10 A”,”value”:”11 A, 10 A”},{“name”:”Institute (CSA)”,”normalizedValue”:”icon”,”value”:”icon”},{“name”:”Push-in force/pole”,”normalizedValue”:”0 N”,”value”:”0 N”},{“name”:”Wire connection cross section AWG, max.”,”normalizedValue”:”AWG 16″,”value”:”AWG 16″},{“name”:”Wire connection cross section AWG, min.”,”normalizedValue”:”AWG 26″,”value”:”AWG 26″},{“name”:”Contact material”,”normalizedValue”:”Cu-Leg”,”value”:”Cu-Leg”},{“name”:”Colour chart (similar)”,”normalizedValue”:”RAL 2000″,”value”:”RAL 2000″},{“name”:”Operating temperature, max.”,”normalizedValue”:”120 deg C”,”value”:”120 °C”},{“name”:”w. wire end ferrule, DIN 46228 pt 1, max.”,”normalizedValue”:”1.5 sq mm”,”value”:”1.5 mm²”},{“name”:”Rated voltage (use group B)”,”normalizedValue”:”300 V, 300 V”,”value”:”300 V, 300 V”},{“name”:”Flexible, min. H05(07) V-K”,”normalizedValue”:”0.14 sq mm”,”value”:”0.14 mm²”},{“name”:”W. wire end ferrule, DIN 46228 pt 1, min”,”normalizedValue”:”0.25 mm²”,”value”:”0.25 mm²”},{“name”:”Pin series quantity”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Insulation Resistance”,”normalizedValue”:”≥10″,”value”:”≥10″},{“name”:”Wire connection method”,”normalizedValue”:”PUSH IN”,”value”:”PUSH IN”},{“name”:”Colour”,”normalizedValue”:”orange”,”value”:”Orange”},{“name”:”Rated current, max. no. of poles (Ta = 20°C)”,”normalizedValue”:”17.5 A”,”value”:”17.5 A”},{“name”:”L1 in inches”,”normalizedValue”:”0.6 in”,”value”:”0.6 inch”},{“name”:”No. of poles”,”normalizedValue”:”5″,”value”:”5″},{“name”:”w. plastic collar ferrule, DIN 46228 pt 4, max.”,”normalizedValue”:”1 sq mm”,”value”:”1 mm²”},{“name”:”Plugging cycles”,”normalizedValue”:”25″,”value”:”25″},{“name”:”Certificate No. (CSA)”,”normalizedValue”:”200,039 to 1,121,690″,”value”:”200039-1121690″},{“name”:”Actuating force actuating element, max.”,”normalizedValue”:”40 N”,”value”:”40 N”},{“name”:”Rated voltage for surge voltage class / pollution degree II/2″,”normalizedValue”:”320 V”,”value”:”320 V”},{“name”:”Storage temperature, max.”,”normalizedValue”:”55 °C”,”value”:”55 °C”},{“name”:”Certificate No. (cURus)”,”normalizedValue”:”E60693″,”value”:”E60693″},{“name”:”Wire cross-section, AWG, max.”,”normalizedValue”:”AWG 16″,”value”:”AWG 16″},{“name”:”Temperature range, installation, max.”,”normalizedValue”:”120 deg C”,”value”:”120 °C”},{“name”:”Volume resistance”,”normalizedValue”:”6 milliohm”,”value”:”6.00 mΩ”},{“name”:”Contact surface”,”normalizedValue”:”tinned”,”value”:”tinned”},{“name”:”Rated voltage (use group D)”,”normalizedValue”:”300 V”,”value”:”300 V”},{“name”:”Institute (cURus)”,”normalizedValue”:”icon”,”value”:”icon”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”China”,”value”:”China”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.