Description
[{“name”:”Item”,”normalizedValue”:”BYV Series PVC Body”,”rank”:1,”value”:”BYV Series PVC Body”},{“name”:”Body Material”,”normalizedValue”:”PVC”,”rank”:3,”value”:”PVC”},{“name”:”Connection”,”normalizedValue”:”Flange”,”rank”:4,”value”:”Flange”},{“name”:”Pipe Size”,”normalizedValue”:”2-1/2 in”,”rank”:4,”value”:”2 1/2 in”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:4,”value”:”120V AC”},{“name”:”Max. Water Pressure”,”normalizedValue”:”150 psi”,”rank”:5,”value”:”150 psi WOG”},{“name”:”Compliance”,”normalizedValue”:”NSF/ASTM-61; NSF/ASTM-362; ISO 5211; ANSI B16.10; ISO 5752″,”value”:”NSF/ASTM-61; NSF/ASTM-362; ISO 5211; ANSI B16.10; ISO 5752″},{“name”:”Number of Bolt Holes”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Lug Dia.”,”normalizedValue”:”3/4 in”,”value”:”3/4 in”},{“name”:”Standards”,”normalizedValue”:”ASTM D1784, NSF Certified”,”value”:”ASTM D1784, NSF Certified”},{“name”:”Seal Material”,”normalizedValue”:”EPDM”,”value”:”EPDM”},{“name”:”Disc Material”,”normalizedValue”:”PVC”,”value”:”PVC”},{“name”:”Bolt Circle Dia.”,”normalizedValue”:”5-1/2 in”,”value”:”5 1/2 in”},{“name”:”Seat Material”,”normalizedValue”:”EPDM”,”value”:”EPDM”},{“name”:”Liner Material”,”normalizedValue”:”EPDM”,”value”:”EPDM”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”34 deg F”,”value”:”34 Degrees F”},{“name”:”Connection Type”,”normalizedValue”:”Lug”,”value”:”Lug”},{“name”:”Maximum Pressure – Steam”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Actuator Input Control Signal”,”normalizedValue”:”Manual”,”value”:”Manual”},{“name”:”Actuator Series”,”normalizedValue”:”HRS”,”value”:”HRS”},{“name”:”IP Rating”,”normalizedValue”:”IP67″,”value”:”IP67″},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”4, 4X”,”value”:”4, 4X”},{“name”:”For Media”,”normalizedValue”:”Gas, Oil, Water”,”value”:”Gas, Oil, Water”},{“name”:”Number of Flange Bolt Holes”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Valve Deactivated State”,”normalizedValue”:”Normally Closed”,”value”:”Normally Closed (NC)”},{“name”:”Maximum Pressure – Operating”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”NSF Certifications for Food and Drinking Water”,”normalizedValue”:”NSF 61″,”value”:”NSF 61″},{“name”:”Lug Diameter”,”normalizedValue”:”3/4 in”,”value”:”3/4 in”},{“name”:”Vacuum Service Rating”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Fail Safe Position”,”normalizedValue”:”Fail Last”,”value”:”Fail Last”},{“name”:”Nominal Valve Size”,”normalizedValue”:”2-1/2 in”,”value”:”2 1/2 in”},{“name”:”Actuator Features”,”normalizedValue”:”Auxiliary Limit Switch, Heater”,”value”:”Auxiliary Limit Switch, Heater”},{“name”:”ANSI Flange Class”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”165″,”value”:”165″},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Disc Alignment”,”normalizedValue”:”Concentric”,”value”:”Concentric”},{“name”:”3-A Standard Compliance”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Average Surface Roughness (Ra)”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Valve Series”,”normalizedValue”:”BYV”,”value”:”BYV”},{“name”:”Actuator Duty Cycle”,”normalizedValue”:”75 %”,”value”:”75 %”},{“name”:”Actuator Electrical Entry”,”normalizedValue”:”1/2 in Conduit, NPT Conduit”,”value”:”1/2 in NPT Conduit”},{“name”:”Actuator Enclosure Material”,”normalizedValue”:”Epoxy-Coated Aluminum”,”value”:”Epoxy-Coated Aluminum”},{“name”:”Actuator Ambient Temperature – Minimum”,”normalizedValue”:”-22 deg F”,”value”:”-22 Degrees F”},{“name”:”Stem Material”,”normalizedValue”:”303 Stainless Steel”,”value”:”303 Stainless Steel”},{“name”:”Actuator Ambient Temperature – Maximum”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.