Air velocity transmitter, 12″ (304.8 mm) probe length.

$686,99

Air Velocity Transmitter, Digital Display Screen Type No Display, Response Time 1.5 sec, Maximum Operating Temperature 140 Degrees F, Probe Diameter 0.5 in, Maximum Output Signal 20 mA, Maximum Temperature Measured 212 Degrees F, Maximum Velocity Measured 15,000 fpm, Minimum Operating Temperature 32 Degrees F, Minimum Temperature Measured -40 Degrees F, Minimum Velocity Measured 250 fpm, Minimum Output Signal 4 mA, Pressure Limit 100 psi, Air Velocity Accuracy +/-3 Percent (32 to 122 Degrees F)

9999 in stock

SKU: GRG5518387 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Air Velocity Transmitter”,”rank”:1,”value”:”Air Velocity Transmitter”},{“name”:”Air Velocity Accuracy”,”normalizedValue”:”+/-3% (32 to 122 Degrees F)”,”rank”:2,”value”:”+/-3% (32 to 122 Degrees F)”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”1″,”rank”:4,”value”:”1″},{“name”:”Velocity Ranges”,”normalizedValue”:”FPM: 250, 500, 1000, 2000, 3000, 5000, 10000, 15000″,”value”:”FPM: 250, 500, 1000, 2000, 3000, 5000, 10000, 15000″},{“name”:”Operating Temp.”,”normalizedValue”:”Process: -40 to 212 Degrees F (-40 to 100 Degrees C) Ambient: 32 to 140 Degrees F (0 to 60 Degrees C)”,”value”:”Process: -40 to 212 Degrees F (-40 to 100 Degrees C) Ambient: 32 to 140 Degrees F (0 to 60 Degrees C)”},{“name”:”Output”,”normalizedValue”:”4 to 20ma DC”,”value”:”4 to 20ma DC”},{“name”:”Dia. (In.)”,”normalizedValue”:”1/2″,”value”:”1/2 in”},{“name”:”Response Time (Sec.)”,”normalizedValue”:”1.5 Seconds to 95% of Final Value (Output Filter Set to Minimum)”,”value”:”1.5 Seconds to 95% of Final Value (Output Filter Set to Minimum)”},{“name”:”Velocity Accuracy”,”normalizedValue”:”3% FS Process gas: 32 to 122 Degrees F (0 to 50 Degrees C); 4% FS Process gas: -40 to 32 Degrees F \u0026 122 to 212 Degrees F (-40 to 0 Degrees C \u0026 50 to 100 Degrees C)”,”value”:”3% FS Process gas: 32 to 122 Degrees F (0 to 50 Degrees C); 4% FS Process gas: -40 to 32 Degrees F \u0026 122 to 212 Degrees F (-40 to 0 Degrees C \u0026 50 to 100 Degrees C)”},{“name”:”Max. Pressure (PSI)”,”normalizedValue”:”100″,”value”:”100 psi”},{“name”:”Probe Length (In.)”,”normalizedValue”:”12″,”value”:”12 in”},{“name”:”Power Required”,”normalizedValue”:”10 to 16 VAC 1.5A Rating Required on Supply Due to Initial Power Surge Drawn by Transmitter, 12 to 35 VDC”,”value”:”10 to 16 VAC 1.5A Rating Required on Supply Due to Initial Power Surge Drawn by Transmitter, 12 to 35 VDC”},{“name”:”Display Type”,”normalizedValue”:””,”value”:”None”},{“name”:”Response Time”,”normalizedValue”:”1.5 sec”,”value”:”1.5 sec”},{“name”:”Maximum Velocity Measured”,”normalizedValue”:”15,000 fpm”,”value”:”15,000 fpm”},{“name”:”Minimum Velocity Measured”,”normalizedValue”:”250 fpm”,”value”:”250 fpm”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Maximum Probe Length”,”normalizedValue”:”12 in”,”value”:”12 in”},{“name”:”Maximum DC Voltage Required”,”normalizedValue”:”35 V”,”value”:”35 V”},{“name”:”Minimum Output Signal”,”normalizedValue”:”4 mA”,”value”:”4 mA”},{“name”:”Digital Display Screen Type”,”normalizedValue”:”No Display”,”value”:”No Display”},{“name”:”Pressure Limit”,”normalizedValue”:”100 psi”,”value”:”100 psi”},{“name”:”Minimum AC Voltage Required”,”normalizedValue”:”10 V”,”value”:”10 V”},{“name”:”Minimum DC Voltage Required”,”normalizedValue”:”12 V”,”value”:”12 V”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”1 yr”,”value”:”1 yr”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Minimum Temperature Measured”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Maximum AC Voltage Required”,”normalizedValue”:”16 V”,”value”:”16 V”},{“name”:”Maximum Temperature Measured”,”normalizedValue”:”212 deg F”,”value”:”212 Degrees F”},{“name”:”Maximum Output Signal”,”normalizedValue”:”20 mA”,”value”:”20 mA”},{“name”:”Probe Diameter”,”normalizedValue”:”1/2 in”,”value”:”0.5 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Air velocity transmitter, 12″ (304.8 mm) probe length.”