AdjCurrntSensrRely, 8A, 24-240VAC/DC, 12Pin, Schneider Electric, Mfr#: RM22JA21MR

$128,99

Adjustable Current Sensing Relay, Contact Rating (AC) 8 A @ 24/240V, Current Rating 8 A, Input Voltage 24 to 240V AC/DC, Monitored Parameters Overcurrent, Mounting Style DIN Rail, Number of Pins 12, Electrical Connection Terminal Strip, Status Indicator LED, Body Depth 3.13 in, Body Height 3.54 in, Body Width 0.89 in

9999 in stock

SKU: GRG3203305 Category:

Description

[{“name”:”Item – Relay”,”normalizedValue”:”Current Sensing Relay”,”rank”:1,”value”:”Current Sensing Relay”},{“name”:”Input or Control Voltage”,”normalizedValue”:”24 to 240V AC/DC”,”rank”:2,”value”:”24 to 240V AC/DC”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”8A @ 24/240V”,”rank”:3,”value”:”8A @ 24/240V”},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail”,”rank”:5,”value”:”DIN Rail”},{“name”:”Trip Delay”,”normalizedValue”:”0.1 to 10 sec”,”rank”:9,”value”:”0.1 to 10 sec”},{“name”:”Input Voltage”,”normalizedValue”:”24 to 240V AC/DC”,”value”:”24 to 240V AC/DC”},{“name”:”Overall Height – Relay”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Electrical Connection”,”normalizedValue”:”Terminal Strip”,”value”:”Terminal Strip”},{“name”:”Type of Output”,”normalizedValue”:”Relay”,”value”:”Relay”},{“name”:”Max. Inrush Current”,”normalizedValue”:”8 A”,”value”:”8.0 A”},{“name”:”Width”,”normalizedValue”:”22.5 mm”,”value”:”22.5 mm”},{“name”:”Body Width – Relay”,”normalizedValue”:”0.89 in”,”value”:”0.89 in”},{“name”:”Status Indicator”,”normalizedValue”:”LED Indicator”,”value”:”LED”},{“name”:”Item”,”normalizedValue”:”Adjustable Current Sensing Relay”,”value”:”Adjustable Current Sensing Relay”},{“name”:”Body Depth – Relay”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Body Height – Relay”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Current Rating”,”normalizedValue”:”8 A”,”value”:”8 A”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250 V AC”,”value”:”250V AC”},{“name”:”Body Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Overall Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Standards”,”normalizedValue”:”CCC, CE Certified, CSA Certified, EAC, EN/IEC 60255-1, GL, RCM, UL Listed”,”value”:”CCC, CE Certified, CSA Certified, EAC, EN/IEC 60255-1, GL, RCM, UL Listed”},{“name”:”Monitored Parameters”,”normalizedValue”:”Overcurrent”,”value”:”Overcurrent”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Minimum Switching Current”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Body Height”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Contact Rating (AC)”,”normalizedValue”:”8 A @ 24/240V”,”value”:”8 A @ 24/240V”},{“name”:”Weight”,”normalizedValue”:”0.24 lb”,”value”:”0.24 lb”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”10,000,000″,”value”:”10,000,000″},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail”,”value”:”DIN Rail”},{“name”:”IP Rating”,”normalizedValue”:”IP20, IP50, IP40″,”value”:”IP20; IP40; IP50″},{“name”:”Power Consumption”,”normalizedValue”:”3.5 VA”,”value”:”3.5 VA”},{“name”:”Body Width”,”normalizedValue”:”0.89 in”,”value”:”0.89 in”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Number of Pins”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”2,000 VA”,”value”:”2,000 VA”},{“name”:”Mounting Support”,”normalizedValue”:”35 mm DIN rail conforming to EN/IEC 60715″,”value”:”35 mm DIN rail conforming to EN/IEC 60715″},{“name”:”Insulation Resistance”,”normalizedValue”:”u003e 100 MOhm 500 V DC IEC 60255-27″,”value”:”u003e 100 MOhm 500 V DC IEC 60255-27″},{“name”:”Maximum Power Consumption In W”,”normalizedValue”:”1.5 W DC”,”value”:”1.5 W DC”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”2 C, O”,”value”:”2 C/O”},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”24 to 240 V AC/DC 50/60 Hz +/- 10 %”,”value”:”24 to 240 V AC/DC 50/60 Hz +/- 10 %”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Response Time”,”normalizedValue”:”u003c= 500 ms”,”value”:”u003c= 500 ms”},{“name”:”Run-Up Delay At Power-Up”,”normalizedValue”:”0.3 sec”,”value”:”0.3 s”},{“name”:”Contacts Material”,”normalizedValue”:”cadmium free”,”value”:”cadmium free”},{“name”:”Supply Voltage Limits”,”normalizedValue”:”20.4-264 V AC, DC”,”value”:”20.4-264 V AC/DC”},{“name”:”Resistance Across Terminals”,”normalizedValue”:”2.5 Ohm E1-M terminals || 0.5 Ohm E2-M terminals || 0.1 Ohm E3-M terminals”,”value”:”2.5 Ohm E1-M terminals || 0.5 Ohm E2-M terminals || 0.1 Ohm E3-M terminals”},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22″,”value”:”immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22″},{“name”:”Dielectric Test Voltage”,”normalizedValue”:”2.5 kV AC 50 Hz, 1 min IEC 60255-27″,”value”:”2.5 kV AC 50 Hz, 1 min IEC 60255-27″},{“name”:”Insulation”,”normalizedValue”:”between supply and measurement”,”value”:”between supply and measurement”},{“name”:”Relay Monitored Parameters”,”normalizedValue”:”overcurrent detection”,”value”:”overcurrent detection”},{“name”:”Maximum Measuring Cycle”,”normalizedValue”:”100 ms measurement cycle as true rms value”,”value”:”100 ms measurement cycle as true rms value”},{“name”:”Output Contacts”,”normalizedValue”:”2 C/O”,”value”:”2 C/O”},{“name”:”Measurement Error”,”normalizedValue”:”u003c 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation”,”value”:”u003c 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation”},{“name”:”Measurement Range”,”normalizedValue”:”4 to 40 mA E1-M terminals || 20 to 200 mA E2-M terminals || 100 to 1000 mA E3-M terminals || 4 mA to 1 A current AC/DC 50/60 Hz”,”value”:”4 to 40 mA E1-M terminals || 20 to 200 mA E2-M terminals || 100 to 1000 mA E3-M terminals || 4 mA to 1 A current AC/DC 50/60 Hz”},{“name”:”Switching Threshold Drift”,”normalizedValue”:”u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range”,”value”:”u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1″,”value”:”AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1″},{“name”:”Local Signalling”,”normalizedValue”:”for relay ON LED (yellow) || for power ON LED (green)”,”value”:”for relay ON LED (yellow) || for power ON LED (green)”},{“name”:”Product Or Component Type”,”normalizedValue”:”current control relay”,”value”:”current control relay”},{“name”:”Repeat Accuracy”,”normalizedValue”:”+/- 0.5 % input and measurement circuit || +/- 0.2 % time delay”,”value”:”+/- 0.5 % input and measurement circuit || +/- 0.2 % time delay”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals, 2 x 0.5 to 2 x 2.5 mm² AWG 20 to AWG 14) solid without cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) flexible with cable end || screw terminals, 1 x 0.5 to 1 x 3.3 mm² AWG 20 to AWG 12) solid without cable end || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end”,”value”:”screw terminals, 2 x 0.5 to 2 x 2.5 mm² AWG 20 to AWG 14) solid without cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) flexible with cable end || screw terminals, 1 x 0.5 to 1 x 3.3 mm² AWG 20 to AWG 12) solid without cable end || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end”},{“name”:”Product Certifications”,”normalizedValue”:”EAC || CSA || CE || RCM || CCC || UL || GL”,”value”:”EAC || CSA || CE || RCM || CCC || UL || GL”},{“name”:”Mechanical Durability”,”normalizedValue”:”10,000,000 cycle”,”value”:”10000000 cycles”},{“name”:”Nominal Output Current”,”normalizedValue”:”8 A”,”value”:”8A”},{“name”:”Internal Input Resistance”,”normalizedValue”:”0.1 Ohm || 2.5 Ohm || 0.5 Ohm”,”value”:”0.1 Ohm || 2.5 Ohm || 0.5 Ohm”},{“name”:”Overvoltage Category”,”normalizedValue”:”III IEC 60664-1 || III UL 508″,”value”:”III IEC 60664-1 || III UL 508″},{“name”:”Relay Type”,”normalizedValue”:”current control relay”,”value”:”current control relay”},{“name”:”Maximum Switching Current”,”normalizedValue”:”8 A AC”,”value”:”8 A AC”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”50 ms”,”value”:”50 ms”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60664-1 || 3 UL 508″,”value”:”3 IEC 60664-1 || 3 UL 508″},{“name”:”Tightening Torque”,”normalizedValue”:”0.6-1 N.m IEC 60947-1″,”value”:”0.6-1 N.m IEC 60947-1″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C 60 Hz || -20-60°C 50 Hz”,”value”:”-20-50°C 60 Hz || -20-60°C 50 Hz”},{“name”:”Switching Capacity In Va”,”normalizedValue”:”2,000 VA”,”value”:”2000 VA”},{“name”:”Electrical Durability”,”normalizedValue”:”100,000 cycle”,”value”:”100000 cycles”},{“name”:”Relative Humidity”,”normalizedValue”:”93-97 % 25-55°C IEC 60068-2-30″,”value”:”93-97 % 25-55°C IEC 60068-2-30″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)”,”value”:”IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)”},{“name”:”Reset Time”,”normalizedValue”:”1500 ms at maximum voltage”,”value”:”1500 ms at maximum voltage”},{“name”:”Setting Accuracy Of Time Delay”,”normalizedValue”:”0.916666666666667″,”value”:”0.916666666666667″},{“name”:”Time Delay Drift”,”normalizedValue”:”u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range”,”value”:”u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range”},{“name”:”Time Delay Type”,”normalizedValue”:”without”,”value”:”without”},{“name”:”Maximum Power Consumption In Va”,”normalizedValue”:”3.5 VA”,”value”:”3.5 VA”},{“name”:”Housing Material”,”normalizedValue”:”Self-Extinguishing Plastic”,”value”:”self-extinguishing plastic”},{“name”:”Relay Name”,”normalizedValue”:”RM22JA”,”value”:”RM22JA”},{“name”:”Threshold Setting”,”normalizedValue”:”10 to 100 %”,”value”:”10 to 100 %”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”15 % + 10 % Un”,”value”:”15 % + 10 % Un”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6″,”value”:”0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6″},{“name”:”Setting Accuracy Of The Switching Threshold”,”normalizedValue”:”+/- 10 % of the full scale”,”value”:”+/- 10 % of the full scale”},{“name”:”Hysteresis”,”normalizedValue”:”5-50 % adjustable threshold setting”,”value”:”5-50 % adjustable threshold setting”},{“name”:”Shock Resistance”,”normalizedValue”:”15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27″,”value”:”15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “AdjCurrntSensrRely, 8A, 24-240VAC/DC, 12Pin, Schneider Electric, Mfr#: RM22JA21MR”