Description
[{“name”:”Item – Relay”,”normalizedValue”:”Current Sensing Relay”,”rank”:1,”value”:”Current Sensing Relay”},{“name”:”Input or Control Voltage”,”normalizedValue”:”24 to 240V AC/DC”,”rank”:2,”value”:”24 to 240V AC/DC”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”8A @ 24/240V”,”rank”:3,”value”:”8A @ 24/240V”},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail”,”rank”:5,”value”:”DIN Rail”},{“name”:”Trip Delay”,”normalizedValue”:”0.1 to 10 sec”,”rank”:9,”value”:”0.1 to 10 sec”},{“name”:”Input Voltage”,”normalizedValue”:”24 to 240V AC/DC”,”value”:”24 to 240V AC/DC”},{“name”:”Overall Height – Relay”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Electrical Connection”,”normalizedValue”:”Terminal Strip”,”value”:”Terminal Strip”},{“name”:”Type of Output”,”normalizedValue”:”Relay”,”value”:”Relay”},{“name”:”Max. Inrush Current”,”normalizedValue”:”8 A”,”value”:”8.0 A”},{“name”:”Width”,”normalizedValue”:”22.5 mm”,”value”:”22.5 mm”},{“name”:”Body Width – Relay”,”normalizedValue”:”0.89 in”,”value”:”0.89 in”},{“name”:”Status Indicator”,”normalizedValue”:”LED Indicator”,”value”:”LED”},{“name”:”Item”,”normalizedValue”:”Adjustable Current Sensing Relay”,”value”:”Adjustable Current Sensing Relay”},{“name”:”Body Depth – Relay”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Body Height – Relay”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Current Rating”,”normalizedValue”:”8 A”,”value”:”8 A”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250 V AC”,”value”:”250V AC”},{“name”:”Body Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Overall Depth”,”normalizedValue”:”3.13 in”,”value”:”3.13 in”},{“name”:”Standards”,”normalizedValue”:”CCC, CE Certified, CSA Certified, EAC, EN/IEC 60255-1, GL, RCM, UL Listed”,”value”:”CCC, CE Certified, CSA Certified, EAC, EN/IEC 60255-1, GL, RCM, UL Listed”},{“name”:”Monitored Parameters”,”normalizedValue”:”Overcurrent”,”value”:”Overcurrent”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Minimum Switching Current”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Body Height”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Contact Rating (AC)”,”normalizedValue”:”8 A @ 24/240V”,”value”:”8 A @ 24/240V”},{“name”:”Weight”,”normalizedValue”:”0.24 lb”,”value”:”0.24 lb”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”10,000,000″,”value”:”10,000,000″},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail”,”value”:”DIN Rail”},{“name”:”IP Rating”,”normalizedValue”:”IP20, IP50, IP40″,”value”:”IP20; IP40; IP50″},{“name”:”Power Consumption”,”normalizedValue”:”3.5 VA”,”value”:”3.5 VA”},{“name”:”Body Width”,”normalizedValue”:”0.89 in”,”value”:”0.89 in”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Number of Pins”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”2,000 VA”,”value”:”2,000 VA”},{“name”:”Mounting Support”,”normalizedValue”:”35 mm DIN rail conforming to EN/IEC 60715″,”value”:”35 mm DIN rail conforming to EN/IEC 60715″},{“name”:”Insulation Resistance”,”normalizedValue”:”u003e 100 MOhm 500 V DC IEC 60255-27″,”value”:”u003e 100 MOhm 500 V DC IEC 60255-27″},{“name”:”Maximum Power Consumption In W”,”normalizedValue”:”1.5 W DC”,”value”:”1.5 W DC”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”2 C, O”,”value”:”2 C/O”},{“name”:”[Us] Rated Supply Voltage”,”normalizedValue”:”24 to 240 V AC/DC 50/60 Hz +/- 10 %”,”value”:”24 to 240 V AC/DC 50/60 Hz +/- 10 %”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Response Time”,”normalizedValue”:”u003c= 500 ms”,”value”:”u003c= 500 ms”},{“name”:”Run-Up Delay At Power-Up”,”normalizedValue”:”0.3 sec”,”value”:”0.3 s”},{“name”:”Contacts Material”,”normalizedValue”:”cadmium free”,”value”:”cadmium free”},{“name”:”Supply Voltage Limits”,”normalizedValue”:”20.4-264 V AC, DC”,”value”:”20.4-264 V AC/DC”},{“name”:”Resistance Across Terminals”,”normalizedValue”:”2.5 Ohm E1-M terminals || 0.5 Ohm E2-M terminals || 0.1 Ohm E3-M terminals”,”value”:”2.5 Ohm E1-M terminals || 0.5 Ohm E2-M terminals || 0.1 Ohm E3-M terminals”},{“name”:”Electromagnetic Compatibility”,”normalizedValue”:”immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22″,”value”:”immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22″},{“name”:”Dielectric Test Voltage”,”normalizedValue”:”2.5 kV AC 50 Hz, 1 min IEC 60255-27″,”value”:”2.5 kV AC 50 Hz, 1 min IEC 60255-27″},{“name”:”Insulation”,”normalizedValue”:”between supply and measurement”,”value”:”between supply and measurement”},{“name”:”Relay Monitored Parameters”,”normalizedValue”:”overcurrent detection”,”value”:”overcurrent detection”},{“name”:”Maximum Measuring Cycle”,”normalizedValue”:”100 ms measurement cycle as true rms value”,”value”:”100 ms measurement cycle as true rms value”},{“name”:”Output Contacts”,”normalizedValue”:”2 C/O”,”value”:”2 C/O”},{“name”:”Measurement Error”,”normalizedValue”:”u003c 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation”,”value”:”u003c 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation”},{“name”:”Measurement Range”,”normalizedValue”:”4 to 40 mA E1-M terminals || 20 to 200 mA E2-M terminals || 100 to 1000 mA E3-M terminals || 4 mA to 1 A current AC/DC 50/60 Hz”,”value”:”4 to 40 mA E1-M terminals || 20 to 200 mA E2-M terminals || 100 to 1000 mA E3-M terminals || 4 mA to 1 A current AC/DC 50/60 Hz”},{“name”:”Switching Threshold Drift”,”normalizedValue”:”u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range”,”value”:”u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1″,”value”:”AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1″},{“name”:”Local Signalling”,”normalizedValue”:”for relay ON LED (yellow) || for power ON LED (green)”,”value”:”for relay ON LED (yellow) || for power ON LED (green)”},{“name”:”Product Or Component Type”,”normalizedValue”:”current control relay”,”value”:”current control relay”},{“name”:”Repeat Accuracy”,”normalizedValue”:”+/- 0.5 % input and measurement circuit || +/- 0.2 % time delay”,”value”:”+/- 0.5 % input and measurement circuit || +/- 0.2 % time delay”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw terminals, 2 x 0.5 to 2 x 2.5 mm² AWG 20 to AWG 14) solid without cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) flexible with cable end || screw terminals, 1 x 0.5 to 1 x 3.3 mm² AWG 20 to AWG 12) solid without cable end || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end”,”value”:”screw terminals, 2 x 0.5 to 2 x 2.5 mm² AWG 20 to AWG 14) solid without cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) flexible with cable end || screw terminals, 1 x 0.5 to 1 x 3.3 mm² AWG 20 to AWG 12) solid without cable end || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end”},{“name”:”Product Certifications”,”normalizedValue”:”EAC || CSA || CE || RCM || CCC || UL || GL”,”value”:”EAC || CSA || CE || RCM || CCC || UL || GL”},{“name”:”Mechanical Durability”,”normalizedValue”:”10,000,000 cycle”,”value”:”10000000 cycles”},{“name”:”Nominal Output Current”,”normalizedValue”:”8 A”,”value”:”8A”},{“name”:”Internal Input Resistance”,”normalizedValue”:”0.1 Ohm || 2.5 Ohm || 0.5 Ohm”,”value”:”0.1 Ohm || 2.5 Ohm || 0.5 Ohm”},{“name”:”Overvoltage Category”,”normalizedValue”:”III IEC 60664-1 || III UL 508″,”value”:”III IEC 60664-1 || III UL 508″},{“name”:”Relay Type”,”normalizedValue”:”current control relay”,”value”:”current control relay”},{“name”:”Maximum Switching Current”,”normalizedValue”:”8 A AC”,”value”:”8 A AC”},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”50 ms”,”value”:”50 ms”},{“name”:”Pollution Degree”,”normalizedValue”:”3 IEC 60664-1 || 3 UL 508″,”value”:”3 IEC 60664-1 || 3 UL 508″},{“name”:”Tightening Torque”,”normalizedValue”:”0.6-1 N.m IEC 60947-1″,”value”:”0.6-1 N.m IEC 60947-1″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C 60 Hz || -20-60°C 50 Hz”,”value”:”-20-50°C 60 Hz || -20-60°C 50 Hz”},{“name”:”Switching Capacity In Va”,”normalizedValue”:”2,000 VA”,”value”:”2000 VA”},{“name”:”Electrical Durability”,”normalizedValue”:”100,000 cycle”,”value”:”100000 cycles”},{“name”:”Relative Humidity”,”normalizedValue”:”93-97 % 25-55°C IEC 60068-2-30″,”value”:”93-97 % 25-55°C IEC 60068-2-30″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)”,”value”:”IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)”},{“name”:”Reset Time”,”normalizedValue”:”1500 ms at maximum voltage”,”value”:”1500 ms at maximum voltage”},{“name”:”Setting Accuracy Of Time Delay”,”normalizedValue”:”0.916666666666667″,”value”:”0.916666666666667″},{“name”:”Time Delay Drift”,”normalizedValue”:”u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range”,”value”:”u003c= 0.05 % per degree centigrade depending permissible ambient air temperature || u003c= 1 % within the supply voltage range”},{“name”:”Time Delay Type”,”normalizedValue”:”without”,”value”:”without”},{“name”:”Maximum Power Consumption In Va”,”normalizedValue”:”3.5 VA”,”value”:”3.5 VA”},{“name”:”Housing Material”,”normalizedValue”:”Self-Extinguishing Plastic”,”value”:”self-extinguishing plastic”},{“name”:”Relay Name”,”normalizedValue”:”RM22JA”,”value”:”RM22JA”},{“name”:”Threshold Setting”,”normalizedValue”:”10 to 100 %”,”value”:”10 to 100 %”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”15 % + 10 % Un”,”value”:”15 % + 10 % Un”},{“name”:”Vibration Resistance”,”normalizedValue”:”0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6″,”value”:”0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6″},{“name”:”Setting Accuracy Of The Switching Threshold”,”normalizedValue”:”+/- 10 % of the full scale”,”value”:”+/- 10 % of the full scale”},{“name”:”Hysteresis”,”normalizedValue”:”5-50 % adjustable threshold setting”,”value”:”5-50 % adjustable threshold setting”},{“name”:”Shock Resistance”,”normalizedValue”:”15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27″,”value”:”15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.