Description
[{“name”:”Item”,”normalizedValue”:”Adjustable Current Sensing Relay”,”rank”:1,”value”:”Adjustable Current Sensing Relay”},{“name”:”AC Contact Rating – Relay”,”normalizedValue”:”8A @ 380/415V”,”rank”:3,”value”:”8A @ 380/415V”},{“name”:”Mounting – Relay”,”normalizedValue”:”DIN Rail”,”rank”:5,”value”:”DIN Rail”},{“name”:”Trip Delay”,”normalizedValue”:”0.1 to 30 sec”,”rank”:9,”value”:”0.1 to 30 sec”},{“name”:”Status Indicator”,”normalizedValue”:”LED Indicator”,”value”:”LED”},{“name”:”Overall Height – Relay”,”normalizedValue”:”2.84 in”,”value”:”2.84 in”},{“name”:”Body Width – Relay”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Width”,”normalizedValue”:”35 mm”,”value”:”35 mm”},{“name”:”Type of Output”,”normalizedValue”:”Relay”,”value”:”Relay”},{“name”:”Item – Relay”,”normalizedValue”:”Current Sensing Relay”,”value”:”Current Sensing Relay”},{“name”:”Body Height – Relay”,”normalizedValue”:”2.84 in”,”value”:”2.84 in”},{“name”:”Max. Inrush Current”,”normalizedValue”:”8 A”,”value”:”8.0 A”},{“name”:”Input Voltage”,”normalizedValue”:”380 to 415V AC”,”value”:”380 to 415V AC”},{“name”:”Electrical Connection”,”normalizedValue”:”Terminal Strip”,”value”:”Terminal Strip”},{“name”:”Body Depth – Relay”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Power Consumption”,”normalizedValue”:”8 VA”,”value”:”8 VA”},{“name”:”Minimum Switching Current”,”normalizedValue”:”10 mA”,”value”:”10 mA”},{“name”:”Body Width”,”normalizedValue”:”1.38 in”,”value”:”1.38 in”},{“name”:”Mounting Style”,”normalizedValue”:”DIN Rail”,”value”:”DIN Rail”},{“name”:”Frequency”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”Weight”,”normalizedValue”:”0.26 lb”,”value”:”0.26 lb”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250 V AC”,”value”:”250V AC”},{“name”:”Current Rating”,”normalizedValue”:”8 A”,”value”:”8 A”},{“name”:”Body Depth”,”normalizedValue”:”2.84 in”,”value”:”2.84 in”},{“name”:”Housing Material”,”normalizedValue”:”Self-Extinguishing Plastic”,”value”:”Self-Extinguishing Plastic”},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”2,000 VA”,”value”:”2,000 VA”},{“name”:”Mechanical Operating Durability”,”normalizedValue”:”10,000,000″,”value”:”10,000,000″},{“name”:”Monitored Parameters”,”normalizedValue”:”Overcurrent, Undercurrent”,”value”:”Overcurrent, Undercurrent”},{“name”:”Standards”,”normalizedValue”:”CCC, CE Certified, CSA Certified, EAC, EN/IEC 60255-1, GL, RCM, UL Listed”,”value”:”CCC, CE Certified, CSA Certified, EAC, EN/IEC 60255-1, GL, RCM, UL Listed”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Body Height”,”normalizedValue”:”3.54 in”,”value”:”3.54 in”},{“name”:”Electrical Operating Durability”,”normalizedValue”:”100,000″,”value”:”100,000″},{“name”:”Overall Depth”,”normalizedValue”:”2.84 in”,”value”:”2.84 in”},{“name”:”IP Rating”,”normalizedValue”:”IP20, IP50, IP30″,”value”:”IP20; IP30; IP50″},{“name”:”Number of Pins”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Contact Rating (AC)”,”normalizedValue”:”8 A @ 380/415V”,”value”:”8 A @ 380/415V”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”Run-Up Delay At Power-Up”,”normalizedValue”:”0.3 sec”,”value”:”0.3 s”},{“name”:”Dielectric Test Voltage”,”normalizedValue”:”2.5 kV AC 50 Hz, 1 min IEC 60255-27″,”value”:”2.5 kV AC 50 Hz, 1 min IEC 60255-27″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 IEC 60529 terminals) || IP50 IEC 60529 front panel) || IP30 IEC 60529 housing)”,”value”:”IP20 IEC 60529 terminals) || IP50 IEC 60529 front panel) || IP30 IEC 60529 housing)”},{“name”:”Supply Voltage Limits”,”normalizedValue”:”323-456.5 V AC”,”value”:”323-456.5 V AC”},{“name”:”Reset Time”,”normalizedValue”:”1500 ms at maximum voltage”,”value”:”1500 ms at maximum voltage”},{“name”:”Mechanical Durability”,”normalizedValue”:”10,000,000 cycle”,”value”:”10000000 cycles”},{“name”:”Switching Capacity In Va”,”normalizedValue”:”2,000 VA”,”value”:”2000 VA”},{“name”:”Output Contacts”,”normalizedValue”:”2 C/O”,”value”:”2 C/O”},{“name”:”Measurement Error”,”normalizedValue”:”< 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation","value":"< 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation"},{"name":"Repeat Accuracy","normalizedValue":"+/- 0.5 % input and measurement circuit || +/- 2 % time delay","value":"+/- 0.5 % input and measurement circuit || +/- 2 % time delay"},{"name":"Local Signalling","normalizedValue":"for relay ON LED (yellow) || for power ON LED (green)","value":"for relay ON LED (yellow) || for power ON LED (green)"},{"name":"Tightening Torque","normalizedValue":"0.6-1 N.m IEC 60947-1","value":"0.6-1 N.m IEC 60947-1"},{"name":"Internal Input Resistance","normalizedValue":"0.005 Ohm || 0.015 Ohm || 0.05 Ohm","value":"0.005 Ohm || 0.015 Ohm || 0.05 Ohm"},{"name":"Environmental Characteristic","normalizedValue":"3K3 C","value":"3K3 C"},{"name":"Ambient Air Temperature For Operation","normalizedValue":"-20-50°C 60 Hz || -20-60°C 50 Hz","value":"-20-50°C 60 Hz || -20-60°C 50 Hz"},{"name":"Relative Humidity","normalizedValue":"93-97 % 25-55°C IEC 60068-2-30","value":"93-97 % 25-55°C IEC 60068-2-30"},{"name":"Electromagnetic Compatibility","normalizedValue":"immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22 || emission standard for residential, commercial and light-industrial environments except radiated emission) EN/IEC 61000-6-3","value":"immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22 || emission standard for residential, commercial and light-industrial environments except radiated emission) EN/IEC 61000-6-3"},{"name":"Measurement Range","normalizedValue":"0.15 to 1.5 A E1-M terminals || 0.5 to 5 A E2-M terminals || 1.5 to 15 A E3-M terminals || 150 mA to 15 A current AC/DC 50/60 Hz","value":"0.15 to 1.5 A E1-M terminals || 0.5 to 5 A E2-M terminals || 1.5 to 15 A E3-M terminals || 150 mA to 15 A current AC/DC 50/60 Hz"},{"name":"Contacts Material","normalizedValue":"cadmium free","value":"cadmium free"},{"name":"Relay Monitored Parameters","normalizedValue":"overcurrent or undercurrent detection || overcurrent or undercurrent in window mode","value":"overcurrent or undercurrent detection || overcurrent or undercurrent in window mode"},{"name":"Immunity To Microbreaks","normalizedValue":"50 ms","value":"50 ms"},{"name":"Time Delay Type","normalizedValue":"adjustable 0.1 to 30 s, +/- 10 % of the full scale value on crossing the threshold Tt","value":"adjustable 0.1 to 30 s, +/- 10 % of the full scale value on crossing the threshold Tt"},{"name":"Contacts Type And Composition","normalizedValue":"2 C, O","value":"2 C/O"},{"name":"Maximum Measuring Cycle","normalizedValue":"100 ms measurement cycle as true rms value","value":"100 ms measurement cycle as true rms value"},{"name":"Hysteresis","normalizedValue":"5-50 % adjustable threshold setting || 3-3 % fixed full scale for window mode","value":"5-50 % adjustable threshold setting || 3-3 % fixed full scale for window mode"},{"name":"Time Delay Drift","normalizedValue":"<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range","value":"<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range"},{"name":"Maximum Switching Current","normalizedValue":"8 A AC","value":"8 A AC"},{"name":"Resistance Across Terminals","normalizedValue":"0.005 Ohm E3-M terminals || 0.015 Ohm E2-M terminals || 0.05 Ohm E1-M terminals","value":"0.005 Ohm E3-M terminals || 0.015 Ohm E2-M terminals || 0.05 Ohm E1-M terminals"},{"name":"Setting Accuracy Of The Switching Threshold","normalizedValue":"+/- 10 % of the full scale || +/- 20 % of the full scale","value":"+/- 10 % of the full scale || +/- 20 % of the full scale"},{"name":"Ambient Air Temperature For Storage","normalizedValue":"-40-70°C","value":"-40-70°C"},{"name":"Overvoltage Category","normalizedValue":"III IEC 60664-1 || III UL 508","value":"III IEC 60664-1 || III UL 508"},{"name":"Pollution Degree","normalizedValue":"3 IEC 60664-1 || 3 UL 508","value":"3 IEC 60664-1 || 3 UL 508"},{"name":"Maximum Power Consumption In Va","normalizedValue":"8 VA","value":"8 VA"},{"name":"Insulation","normalizedValue":"between supply and measurement","value":"between supply and measurement"},{"name":"Insulation Resistance","normalizedValue":"> 100 MOhm 500 V DC IEC 60255-27″,”value”:”> 100 MOhm 500 V DC IEC 60255-27″},{“name”:”Relay Type”,”normalizedValue”:”current control relay”,”value”:”current control relay”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1″,”value”:”AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1″},{“name”:”Response Time”,”normalizedValue”:”<= 500 ms (on crossing the threshold)","value":"<= 500 ms (on crossing the threshold)"},{"name":"Vibration Resistance","normalizedValue":"0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6","value":"0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6"},{"name":"Shock Resistance","normalizedValue":"15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27","value":"15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27"},{"name":"Threshold Setting","normalizedValue":"10 to 100 %","value":"10 to 100 %"},{"name":"Relay Name","normalizedValue":"RM35JA","value":"RM35JA"},{"name":"Control Circuit Voltage Limits","normalizedValue":"15 % + 10 % Un","value":"15 % + 10 % Un"},{"name":"Setting Accuracy Of Time Delay","normalizedValue":"0.916666666666667","value":"0.916666666666667"},{"name":"Connections - Terminals","normalizedValue":"screw terminals, 2 x 0.5 to 2 x 2.5 mm² AWG 20 to AWG 14) solid without cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) flexible with cable end || screw terminals, 1 x 0.5 to 1 x 3.3 mm² AWG 20 to AWG 12) solid without cable end || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end","value":"screw terminals, 2 x 0.5 to 2 x 2.5 mm² AWG 20 to AWG 14) solid without cable end || screw terminals, 2 x 0.2 to 2 x 1.5 mm² AWG 24 to AWG 16) flexible with cable end || screw terminals, 1 x 0.5 to 1 x 3.3 mm² AWG 20 to AWG 12) solid without cable end || screw terminals, 1 x 0.2 to 1 x 2.5 mm² AWG 24 to AWG 14) flexible with cable end"},{"name":"Product Certifications","normalizedValue":"CCC || EAC || CSA || RCM || UL || GL || CE","value":"CCC || EAC || CSA || RCM || UL || GL || CE"},{"name":"Electrical Durability","normalizedValue":"100,000 cycle","value":"100000 cycles"},{"name":"[Us] Rated Supply Voltage","normalizedValue":"380 to 415 V AC 50/60 Hz +/- 10 %","value":"380 to 415 V AC 50/60 Hz +/- 10 %"},{"name":"Mounting Support","normalizedValue":"35 mm DIN rail conforming to EN/IEC 60715","value":"35 mm DIN rail conforming to EN/IEC 60715"},{"name":"Product Or Component Type","normalizedValue":"current control relay","value":"current control relay"},{"name":"Nominal Output Current","normalizedValue":"8 A","value":"8A"},{"name":"Switching Threshold Drift","normalizedValue":"<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range","value":"<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range"},{"name":"Country of Origin (subject to change)","normalizedValue":"Indonesia","value":"Indonesia"},{"name":"Package Quantity","normalizedValue":"1","value":"1"}]

Reviews
There are no reviews yet.