Description
[{“name”:”UPS Type”,”normalizedValue”:”Standby”,”rank”:3,”value”:”Standby”},{“name”:”Transfer Time”,”normalizedValue”:”6 milliseconds (typical) / 10 milliseconds (max.)”,”value”:”6 milliseconds (typical) / 10 milliseconds (max.)”},{“name”:”UPS Output Receptacles (Surge Suppression Only)”,”normalizedValue”:”6 UPS outlets, 6 surge-only outlets”,”value”:”6 UPS outlets, 6 surge-only outlets”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”95″,”value”:”95″},{“name”:”Nominal Voltage Details”,”normalizedValue”:”120v nominal output in battery mode”,”value”:”120v nominal output in battery mode”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”1 min 42 sec”,”value”:”1.7 min. (480w)”},{“name”:”Audible Alarm”,”normalizedValue”:”UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace battery conditions”,”value”:”UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace battery conditions”},{“name”:”PowerAlert Software”,”normalizedValue”:”For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”,”value”:”For local monitoring via the UPS™s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”Touchscreen LCD offers detailed UPS and site electrical data, including output voltage, input voltage, load level percentage, battery charge percentage and ECO-mode status (see manual)”,”value”:”Touchscreen LCD offers detailed UPS and site electrical data, including output voltage, input voltage, load level percentage, battery charge percentage and ECO-mode status (see manual)”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”120V”,”value”:”120V (±20%)”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”3.35 x 5.12 x 12.2″,”value”:”3.35 x 5.12 x 12.2″},{“name”:”Switches”,”normalizedValue”:”Switch controls power off/on status and ECO mode off/on status”,”value”:”Switch controls power off/on status and ECO mode off/on status”},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”7 min 48 sec”,”value”:”7.8 min. (240w)”},{“name”:”WatchDog Compatibility”,”normalizedValue”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”,”value”:”Supports Watchdog application, OS and hard-reboot restart options for remote applications”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”130″,”value”:”130″},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower; Ultra-compact desktop; Wallmount”,”value”:”Tower; Ultra-compact desktop; Wallmount”},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”PWM sine wave”,”value”:”PWM sine wave”},{“name”:”Operating Temperature Range”,”normalizedValue”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”,”value”:”+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius”},{“name”:”UPS Input Cord Length (ft.)”,”normalizedValue”:”5″,”value”:”5″},{“name”:”Output Receptacles”,”normalizedValue”:”5-15R”,”value”:”(12) 5-15R”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”UPS AC Suppression Response Time”,”normalizedValue”:”Instantaneous”,”value”:”Instantaneous”},{“name”:”Output Receptacle Details”,”normalizedValue”:”The ECO Energy-Saving option will automatically POWER OFF four designated ECO outlets when the device connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 24 watts or more (see manual)”,”value”:”The ECO Energy-Saving option will automatically POWER OFF four designated ECO outlets when the device connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 24 watts or more (see manual)”},{“name”:”UPS AC Suppression Joule Rating”,”normalizedValue”:”316″,”value”:”316″},{“name”:”Recommended Electrical Service”,”normalizedValue”:”15A 120V”,”value”:”15A 120V”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”310″,”value”:”310″},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”EMI / RFI AC Noise Suppression”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Input Circuit Breakers”,”normalizedValue”:”10A”,”value”:”10A”},{“name”:”UPS Certification Details”,”normalizedValue”:”UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; Industry Canada Certification#: 3449A-005, REN:0.1B”,”value”:”UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; Industry Canada Certification#: 3449A-005, REN:0.1B”},{“name”:”Frequency Compatibility”,”normalizedValue”:”50 / 60 Hz”,”value”:”50 / 60 Hz”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”120V (±10%)”,”value”:”120V (±10%)”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”6.5 hours from 10% to 90%”,”value”:”6.5 hours from 10% to 90%”},{“name”:”Battery Access”,”normalizedValue”:”Battery access door”,”value”:”Battery access door (see manual)”},{“name”:”Communications Interface”,”normalizedValue”:”USB (HID enabled)”,”value”:”USB (HID enabled)”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”145″,”value”:”145″},{“name”:”AC Mode BTU / Hr. (Full Load)”,”normalizedValue”:”8.3″,”value”:”8.3″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”120 V AC”,”value”:”120V AC”},{“name”:”Primary Form Factor”,”normalizedValue”:”Desktop”,”value”:”Desktop”},{“name”:”Communications Cable”,”normalizedValue”:”USB interface cable included”,”value”:”USB interface cable included”},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”110 V, 115 V, 120 V”,”value”:”110V; 115V; 120V”},{“name”:”Internal UPS Replacement Battery Cartridge”,”normalizedValue”:”RBC51″,”value”:”RBC51″},{“name”:”UPS Input Connection Type”,”normalizedValue”:”5-15P”,”value”:”5-15P”},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”900″,”value”:”900″},{“name”:”Expandable Runtime”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure sine wave”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”85″,”value”:”85″},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”480″,”value”:”480″},{“name”:”UPS Housing Material”,”normalizedValue”:”ABS”,”value”:”ABS”},{“name”:”Input Phase”,”normalizedValue”:”Single-Phase”,”value”:”Single-Phase”},{“name”:”Relative Humidity”,”normalizedValue”:”0 to 90%, non-condensing”,”value”:”0 to 90%, non-condensing”},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”UPS Certifications”,”normalizedValue”:”ENERGY STAR Qualified; Meets FCC Part 15 Category B (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”,”value”:”ENERGY STAR Qualified; Meets FCC Part 15 Category B (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)”},{“name”:”UPS Dataline Suppression”,”normalizedValue”:”1 line TEL/DSL or Ethernet”,”value”:”1 line TEL/DSL or Ethernet”},{“name”:”AC Mode Efficiency Rating (100% Load)”,”normalizedValue”:”>98%”,”value”:”>98%”},{“name”:”Storage Temperature Range”,”normalizedValue”:”to +45 degrees Celsius”,”value”:”+5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.