Description
[{“name”:”Standards”,”normalizedValue”:”UL 508 || EN/IEC 61810-1 || CSA C22.2 No 14″,”value”:”UL 508 || EN/IEC 61810-1 || CSA C22.2 No 14″},{“name”:”Product Or Component Type”,”normalizedValue”:”Plug-in relay”,”value”:”plug-in relay”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”250 V IEC || 300 V CSA || 300 V UL”,”value”:”250 V IEC || 300 V CSA || 300 V UL”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP40 conforming to EN/IEC 60529″,”value”:”IP40 conforming to EN/IEC 60529″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-40-55°C”,”value”:”-40-55°C”},{“name”:”Average Resistance”,”normalizedValue”:”4430 Ohm 20°C +/- 15 %”,”value”:”4430 Ohm 20°C +/- 15 %”},{“name”:”Device Presentation”,”normalizedValue”:”complete product”,”value”:”complete product”},{“name”:”Contacts Material”,”normalizedValue”:”AgNi”,”value”:”AgNi”},{“name”:”Load Current”,”normalizedValue”:”6 A 250 V AC || 6 A 28 V DC”,”value”:”6 A 250 V AC || 6 A 28 V DC”},{“name”:”Drop-Out Voltage Threshold”,”normalizedValue”:”\u003e= 0.15 Uc”,”value”:”\u003e= 0.15 Uc”},{“name”:”Operating Rate”,”normalizedValue”:”\u003c= 1200 cycles/hour under load || \u003c= 18000 cycles/hour no-load”,”value”:”\u003c= 1200 cycles/hour under load || \u003c= 18000 cycles/hour no-load”},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles resistive”,”value”:”100000 cycles resistive”},{“name”:”Minimum Switching Capacity”,”normalizedValue”:”170 mW 10 mA, 17 V”,”value”:”170 mW 10 mA, 17 V”},{“name”:”Shape Of Pin”,”normalizedValue”:”flat”,”value”:”flat”},{“name”:”Average Coil Consumption In Va”,”normalizedValue”:”1.2-1.2 60 Hz”,”value”:”1.2-1.2 60 Hz”},{“name”:”Operating Position”,”normalizedValue”:”any position”,”value”:”any position”},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”3 A 28 V DC) NC IEC || 3 A 250 V AC) NC IEC || 6 A 28 V DC) NO IEC || 6 A 250 V AC) NO IEC || 6 A 277 V AC) UL || 8 A 30 V DC) UL”,”value”:”3 A 28 V DC) NC IEC || 3 A 250 V AC) NC IEC || 6 A 28 V DC) NO IEC || 6 A 250 V AC) NO IEC || 6 A 277 V AC) UL || 8 A 30 V DC) UL”},{“name”:”Control Type”,”normalizedValue”:”Lockable test button”,”value”:”lockable test button”},{“name”:”Mechanical Durability”,”normalizedValue”:”10,000,000 cycle”,”value”:”10000000 cycles”},{“name”:”Vibration Resistance”,”normalizedValue”:”3 gn +/- 1 mm 10-150 Hz)5 cycles in operation || 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating”,”value”:”3 gn +/- 1 mm 10-150 Hz)5 cycles in operation || 5 gn +/- 1 mm 10-150 Hz)5 cycles not operating”},{“name”:”Utilisation Coefficient”,”normalizedValue”:”0.2″,”value”:”0.2″},{“name”:”[Uc] Control Circuit Voltage”,”normalizedValue”:”120 V AC 50/60 Hz”,”value”:”120 V AC 50/60 Hz”},{“name”:”Maximum Switching Capacity”,”normalizedValue”:”1500 VA/168 W”,”value”:”1500 VA/168 W”},{“name”:”Protection Category”,”normalizedValue”:”RTI”,”value”:”RT I”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-85°C”,”value”:”-40-85°C”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”O, 4 C”,”value”:”4 C/O”},{“name”:”Cad Overall Height”,”normalizedValue”:”79 mm”,”value”:”79 mm”},{“name”:”Device Short Name”,”normalizedValue”:”RXM”,”value”:”RXM”},{“name”:”Product Certifications”,”normalizedValue”:”GOST || CE || Lloyd’s || UL || CSA”,”value”:”GOST || CE || Lloyd’s || UL || CSA”},{“name”:”Shock Resistance”,”normalizedValue”:”10 gnin operation || 30 gnnot operating”,”value”:”10 gnin operation || 30 gnnot operating”},{“name”:”Rated Operational Voltage Limits”,”normalizedValue”:”96…132 V AC”,”value”:”96…132 V AC”},{“name”:”Cad Overall Depth”,”normalizedValue”:”78.45 mm”,”value”:”78.45 mm”},{“name”:”Operating Time”,”normalizedValue”:”20 msec”,”value”:”20 ms”},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”2.5 kV 1.2/50µs”,”value”:”2.5 kV 1.2/50µs”},{“name”:”Test Levels”,”normalizedValue”:”level A”,”value”:”level A”},{“name”:”Pollution Degree”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Continuous Output Current”,”normalizedValue”:”5 A”,”value”:”5A”},{“name”:”Dielectric Strength”,”normalizedValue”:”1300 V AC between contacts with micro disconnection || 2000 V AC between coil and contact with basic insulation || 2000 V AC between poles with basic insulation”,”value”:”1300 V AC between contacts with micro disconnection || 2000 V AC between coil and contact with basic insulation || 2000 V AC between poles with basic insulation”},{“name”:”Series Name”,”normalizedValue”:”Miniature”,”value”:”Miniature”},{“name”:”Average Consumption”,”normalizedValue”:”1.2 VA 60 Hz”,”value”:”1.2 VA 60 Hz”},{“name”:”Reset Time”,”normalizedValue”:”20 msec”,”value”:”20 ms”},{“name”:”Maximum Switching Voltage”,”normalizedValue”:”250 V IEC”,”value”:”250 V IEC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.