4 N/O CONTROL RELAY 120V

$83,49

9999 in stock

SKU: GRG410446686 Category:

Description

[{“name”:”Width”,”normalizedValue”:”1.77 in”,”value”:”1.77 in (45 mm)”},{“name”:”Height”,”normalizedValue”:”2.28 in”,”value”:”2.28 in (58 mm)”},{“name”:”Depth”,”normalizedValue”:”2.24 in”,”value”:”2.24 in (57 mm)”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1″,”value”:”EN/IEC 60947-4-1; GB/T 14048.4; UL 60947-4-1; CSA C22.2 No 60947-4-1; JIS C8201-4-1″},{“name”:”Immunity To Microbreaks”,”normalizedValue”:”2 msec”,”value”:”2 ms”},{“name”:”Protective Treatment”,”normalizedValue”:”TC IEC 60068″,”value”:”TC IEC 60068″},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”690 V IEC 60947; 750 V VDE 0110 group C; 690 V BS 5424; 600 V CSA C22.2 No 14″,”value”:”690 V IEC 60947; 750 V VDE 0110 group C; 690 V BS 5424; 600 V CSA C22.2 No 14″},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG conforming to IEC 60947; 10 A gG conforming to VDE 0660″,”value”:”10 A gG conforming to IEC 60947; 10 A gG conforming to VDE 0660″},{“name”:”IRMS Rated Making Capacity”,”normalizedValue”:”110 A IEC 60947″,”value”:”110 A IEC 60947″},{“name”:”Mounting Support”,”normalizedValue”:”Plate; Rail”,”value”:”Plate; Rail”},{“name”:”Product Certifications”,”normalizedValue”:”UL, CB Scheme, CCC, CE, CSA, EAC, UKCA”,”value”:”CB Scheme; CCC; UL; CSA; EAC; CE; UKCA”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”120 V AC 50/60 Hz”,”value”:”120 V AC 50/60 Hz”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP2X”,”value”:”IP2X”},{“name”:”Mechanical Durability”,”normalizedValue”:”10 Mcycles”,”value”:”10 Mcycles”},{“name”:”Inrush Power in VA”,”normalizedValue”:”30 VA (at 68°F (20°C))”,”value”:”30 VA (at 68°F (20°C))”},{“name”:”Heat Dissipation”,”normalizedValue”:”1.3 W”,”value”:”1.3 W”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA”,”value”:”5 mA”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-58 to 176°F”,”value”:”-58 to 176°F (-50 to 80°C)”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”10000 cyc/h”,”value”:”10000 cyc/h”},{“name”:”Product Or Component Type”,”normalizedValue”:”control relay”,”value”:”Control relay”},{“name”:”Hold-In Power Consumption in VA”,”normalizedValue”:”4.5 VA (at 68°F (20°C))”,”value”:”4.5 VA (at 68°F (20°C))”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102″,”value”:”V1 conforming to UL 94; Requirement 2 conforming to NF F 16-101; Requirement 2 conforming to NF F 16-102″},{“name”:”Contactor Application”,”normalizedValue”:”control circuit”,”value”:”Control circuit”},{“name”:”Utilisation Category”,”normalizedValue”:”DC-13; AC-15″,”value”:”DC-13; AC-15″},{“name”:”Product Name”,”normalizedValue”:”TeSys CAK”,”value”:”TeSys CAK”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”Less than or Equal to 690 V Less than or Equal to 400 Hz”,”value”:”Less than or Equal to 690 V Less than or Equal to 400 Hz”},{“name”:”Mechanical Robustness”,”normalizedValue”:”Vibrations contactor open2 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Shocks contactor open10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed15 Gn for 11 ms IEC 60068-2-27″,”value”:”Vibrations contactor open2 Gn, 5 to 300 Hz IEC 60068-2-6; Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6; Shocks contactor open10 Gn for 11 ms IEC 60068-2-27; Shocks contactor closed15 Gn for 11 ms IEC 60068-2-27″},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V”,”value”:”17 V”},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible without cable end”,”value”:”screw clamp terminals 1 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 4 mm²)solid; screw clamp terminals 1 0.00 to 0.01 in² (0.75 to 4 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.01 in² (0.75 to 4 mm²)flexible without cable end; screw clamp terminals 1 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible with cable end; screw clamp terminals 2 0.00 to 0.00 in² (0.34 to 1.5 mm²)flexible without cable end”},{“name”:”Tightening Torque”,”normalizedValue”:”11.51 lbf.in (1.3 N.m) screw clamp terminals flat 6 mm; 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 0.24 in (6 mm); 11.51 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2″,”value”:”11.51 lbf.in (1.3 N.m) screw clamp terminals flat 6 mm; 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 0.24 in (6 mm); 11.51 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2″},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 10 MOhm”,”value”:”Greater than 10 MOhm”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”Drop-out: 0.2 to 0.75 Uc (at Less than 122°F (50°C)); Operational: 0.8 to 1.15 Uc (at Less than 122°F (50°C))”,”value”:”Drop-out: 0.2 to 0.75 Uc (at Less than 122°F (50°C)); Operational: 0.8 to 1.15 Uc (at Less than 122°F (50°C))”},{“name”:”Pole Contact Composition”,”normalizedValue”:”4 NO”,”value”:”4 NO”},{“name”:”Operating Altitude”,”normalizedValue”:”6561.68 ft (2000 m) without derating”,”value”:”6561.68 ft (2000 m) without derating”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 122°F (50°C))”,”value”:”10 A (at 122°F (50°C))”},{“name”:”Operating Time”,”normalizedValue”:”10 to 20 ms coil de-energisation and NO opening; 10 to 20 ms coil energisation and NO closing”,”value”:”10 to 20 ms coil de-energisation and NO opening; 10 to 20 ms coil energisation and NO closing”},{“name”:”Non Overlap Distance”,”normalizedValue”:”0.02 in”,”value”:”0.02 in (0.5 mm)”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-13 to 122°F (-25 to 50°C)”,”value”:”-13 to 122°F (-25 to 50°C)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “4 N/O CONTROL RELAY 120V”