3-Phase Smartonline 10Kva 9Kw Double Conversion Ups W/ Snmp Option

$5210,99

Out of stock

SKU: GRG9400529 Category:

Description

[{“name”:”UPS Type”,”normalizedValue”:”On-Line”,”rank”:3,”value”:”On-Line”},{“name”:”Transfer Time”,”normalizedValue”:”Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode”,”value”:”Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode”},{“name”:”UPS Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”UPS Input Connection Type”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Power Factor”,”normalizedValue”:”0.9″,”value”:”0.9″},{“name”:”UPS Certification Details”,”normalizedValue”:”EN 62040-1-1 (Safety); EN 62040-2 (Category C3)”,”value”:”EN 62040-1-1 (Safety); EN 62040-2 (Category C3)”},{“name”:”Battery Recharge Rate (Included Batteries)”,”normalizedValue”:”4 hours to 90% (Internal batteries)”,”value”:”4 hours to 90% (Internal batteries)”},{“name”:”Output kW Capacity (kW)”,”normalizedValue”:”9″,”value”:”9″},{“name”:”Switches”,”normalizedValue”:”ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP \u0026 MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information)”,”value”:”ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP \u0026 MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information)”},{“name”:”Overvoltage Correction”,”normalizedValue”:”Corrects overvoltage conditions to 520V (50% load) and 478V (100% load)”,”value”:”Corrects overvoltage conditions to 520V (50% load) and 478V (100% load)”},{“name”:”Grounding Lug”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Primary UPS Height (mm)”,”normalizedValue”:”861″,”value”:”861″},{“name”:”Output AC Waveform (Battery Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”LED Indicators”,”normalizedValue”:”4 LEDs report BYPASS / LINE / BATTERY / FAULT modes”,”value”:”4 LEDs report BYPASS / LINE / BATTERY / FAULT modes”},{“name”:”Output Watt Capacity (Watts)”,”normalizedValue”:”9,000″,”value”:”9000″},{“name”:”Nominal Input Voltage(s) Supported”,”normalizedValue”:”220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye”,”value”:”220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye”},{“name”:”Rated input current (Maximum Load)”,”normalizedValue”:”17.4A”,”value”:”17.4A”},{“name”:”Expandable Battery Runtime”,”normalizedValue”:”Supports extended runtime optional external battery packs”,”value”:”Supports extended runtime optional external battery packs”},{“name”:”Output Voltage Regulation (Line Mode)”,”normalizedValue”:”+/- 1%”,”value”:”+/- 1%”},{“name”:”Operating Elevation (m)”,”normalizedValue”:”\u003c 1000m (Capacity de-rates by 1% for every 100m over 1000)”,”value”:”\u003c 1000m (Capacity de-rates by 1% for every 100m over 1000)”},{“name”:”Installation Form Factors Supported with Included Accessories”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Full Load Runtime (min.)”,”normalizedValue”:”3 min 48 sec”,”value”:”3.8 min (9kW)”},{“name”:”Output Voltage Regulation (Battery Mode)”,”normalizedValue”:”+/- 1%”,”value”:”+/- 1%”},{“name”:”Primary UPS Depth (mm)”,”normalizedValue”:”813″,”value”:”813″},{“name”:”Cold Start (Startup in Battery Mode During a Power Failure)”,”normalizedValue”:”Cold-start operation supported”,”value”:”Cold-start operation supported”},{“name”:”Cooling Method”,”normalizedValue”:”Fan”,”value”:”Fans”},{“name”:”Primary UPS Width (mm)”,”normalizedValue”:”249″,”value”:”249″},{“name”:”Nominal Output Voltage(s) Supported”,”normalizedValue”:”220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye”,”value”:”220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye”},{“name”:”Relative Humidity”,”normalizedValue”:”5 to 95%, non-condensing”,”value”:”5 to 95%, non-condensing”},{“name”:”Individually Controllable Load Banks”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Undervoltage Correction”,”normalizedValue”:”Corrects brownout conditions to 110V (50% load) / 305V (100% load)”,”value”:”Corrects brownout conditions to 110V (50% load) / 305V (100% load)”},{“name”:”Front Panel LCD Display”,”normalizedValue”:”LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage \u0026 frequency, estimated runtime and more (see user manual for a detailed listing)”,”value”:”LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage \u0026 frequency, estimated runtime and more (see user manual for a detailed listing)”},{“name”:”Frequency Compatibility”,”normalizedValue”:”50 / 60 Hz”,”value”:”50 / 60 Hz”},{“name”:”Input Phase”,”normalizedValue”:”3-Phase”,”value”:”3-Phase”},{“name”:”High Availability UPS Features”,”normalizedValue”:”Automatic inverter bypass; Manual bypass switch”,”value”:”Automatic inverter bypass; Manual bypass switch”},{“name”:”Crest Factor”,”normalizedValue”:”0.125694444444444″,”value”:”0.125694444444444″},{“name”:”Operating Elevation (ft.)”,”normalizedValue”:”\u003c 3000ft (Capacity de-rates by 1% for every 330ft over 3000)”,”value”:”\u003c 3000ft (Capacity de-rates by 1% for every 330ft over 3000)”},{“name”:”Communications Cable”,”normalizedValue”:”DB9 cabling included”,”value”:”DB9 cabling included”},{“name”:”Output AC Waveform (AC Mode)”,”normalizedValue”:”Pure Sine wave”,”value”:”Pure Sine wave”},{“name”:”Network Management Cards”,”normalizedValue”:”WEBCARDLX, MODBUSCARDSV, RELAYCARDSV”,”value”:”WEBCARDLX ; MODBUSCARDSV ; RELAYCARDSV”},{“name”:”Output Voltage Regulation (Economy Line Mode)”,”normalizedValue”:”+/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V)”,”value”:”+/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V)”},{“name”:”Audible Alarm”,”normalizedValue”:”Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD \u0026 OTHER WARNINGS conditions”,”value”:”Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD \u0026 OTHER WARNINGS conditions”},{“name”:”Network Monitoring Port Description”,”normalizedValue”:”Card accessory slot also supports network interface and relay card options”,”value”:”Card accessory slot also supports network interface and relay card options”},{“name”:”Output Capacity Details”,”normalizedValue”:”Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less”,”value”:”Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less”},{“name”:”Power Factor (Input)”,”normalizedValue”:”.99PF (100% load)”,”value”:”.99PF (100% load)”},{“name”:”Communications Interface”,”normalizedValue”:”DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”,”value”:”DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface”},{“name”:”High Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”520V (50% load) / 478V (100% load)”,”value”:”520V (50% load) / 478V (100% load)”},{“name”:”Storage Temperature Range”,”normalizedValue”:”0 to +35C with battery; -15, to 60C without battery”,”value”:”0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery”},{“name”:”Expandable Runtime”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”UPS Power Module Dimensions (hwd, in.)”,”normalizedValue”:”33.9 x 9.8 x 32″,”value”:”33.9 x 9.8 x 32″},{“name”:”Output Volt Amp Capacity (VA)”,”normalizedValue”:”10,000″,”value”:”10000″},{“name”:”Audible Noise”,”normalizedValue”:”\u003c65dBA front side 1M”,”value”:”\u003c65dBA front side 1M”},{“name”:”Nominal Input Voltage Description”,”normalizedValue”:”3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)”,”value”:”3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)”},{“name”:”UPS Certifications”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”THDi”,”normalizedValue”:”\u003c6%”,”value”:”\u003c6%”},{“name”:”Primary Form Factor”,”normalizedValue”:”Tower”,”value”:”Tower”},{“name”:”Half Load Runtime (min.)”,”normalizedValue”:”10 min 30 sec”,”value”:”10.5 min. (4.5kW)”},{“name”:”Operating Temperature Range”,”normalizedValue”:”0 to +40C (32-104F)”,”value”:”0 to +40C (32-104F)”},{“name”:”Voltage Regulation Description”,”normalizedValue”:”Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode”,”value”:”Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode”},{“name”:”Low Voltage Transfer to Battery Power (Setpoint)”,”normalizedValue”:”110V (50% load) / 305V (100% load)”,”value”:”110V (50% load) / 305V (100% load)”},{“name”:”Output Receptacles”,”normalizedValue”:”Hardwire”,”value”:”Hardwire”},{“name”:”Frequency Compatibility Details”,”normalizedValue”:”Automatic frequency selection”,”value”:”Automatic frequency selection”},{“name”:”Output kVA Capacity (kVA)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”DC System Voltage (VDC)”,”normalizedValue”:”240″,”value”:”240″},{“name”:”External Battery Pack Compatibility”,”normalizedValue”:”BP240V135″,”value”:”BP240V135″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “3-Phase Smartonline 10Kva 9Kw Double Conversion Ups W/ Snmp Option”