3″ x 6 ft. Pipe Insulation, 1/2″ Wall, K-Flex Usa, Mfr#: 6RX048348

$24,85

Pipe Insulation, Insulation Material Buna-N Rubber/PVC, Installation Style Unslit, Inside Diameter 3 1/2 in, Wall Thickness 1/2 in, Overall Length 6 ft, Minimum Operating Temperature -297 Degrees F, Maximum Operating Temperature 220 Degrees F, Jacket Material Unfaced, Color Black, R Value 3, Form Tube, For Copper Tube Size Not Applicable, For Pipe Size 3 in, Flame Spread Index 32, Smoke Developed Index 57, Foam Cell Type Closed, Plenum Rating Plenum Rated, Flexibility Flexible

9999 in stock

SKU: GRG1269484 Category:

Description

[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Wall Thickness”,”normalizedValue”:”1/2 in”,”rank”:1,”value”:”1/2 in”},{“name”:”Length”,”normalizedValue”:”6 ft”,”rank”:2,”value”:”6 ft.”},{“name”:”For Iron Pipe Size”,”normalizedValue”:”3″”,”rank”:4,”value”:”3″”},{“name”:”Material”,”normalizedValue”:”NBR/PVC Based Elastomeric”,”rank”:5,”value”:”NBR/PVC Based Elastomeric”},{“name”:”Item”,”normalizedValue”:”Pipe Insulation”,”value”:”Pipe Insulation”},{“name”:”Standards”,”normalizedValue”:”ASTM C 534 Type 1 Tubing; ASTM D 1056-00-2C1; New York City MEA 186-86-M Vol. IV; USDA Requirements, Meets requirements of ASTM C 411 (Test Method for Hot Surface performance of High Temperature Thermal Insulation); Meets requirements of UL 181 sections 11.0 and 16.0 (Mold Growth/Air Erosion), MIL-P-15280 For T (Tubing), UL 94-5V Flammability Classification (Recognition # E300774); ASTM E84 1-1/2 in 25/50 Tested according to UL 723 and NFPA 255; Complies with requirements of CAN/ULC S102-M88; FMRC 2006 Approval Guide Chapter 14 Pipe Insulation; NFPA No 101 Class A Rating; Meets requirements of NFPA 90A Sect 2.3.3 for Supplementary materials for Air Distribution Systems”,”value”:”ASTM C 534 Type 1 Tubing; ASTM D 1056-00-2C1; New York City MEA 186-86-M Vol. IV; USDA Requirements, Meets requirements of ASTM C 411 (Test Method for Hot Surface performance of High Temperature Thermal Insulation); Meets requirements of UL 181 sections 11.0 and 16.0 (Mold Growth/Air Erosion), MIL-P-15280 For T (Tubing), UL 94-5V Flammability Classification (Recognition # E300774); ASTM E84 1-1/2 in 25/50 Tested according to UL 723 and NFPA 255; Complies with requirements of CAN/ULC S102-M88; FMRC 2006 Approval Guide Chapter 14 Pipe Insulation; NFPA No 101 Class A Rating; Meets requirements of NFPA 90A Sect 2.3.3 for Supplementary materials for Air Distribution Systems”},{“name”:”Insulation Max. Thickness”,”normalizedValue”:”1/2 in”,”value”:”1/2″”},{“name”:”Color”,”normalizedValue”:”Black”,”value”:”Black”},{“name”:”Insulation Length”,”normalizedValue”:”6 ft”,”value”:”6 ft”},{“name”:”Green Certification or Other Recognition”,”normalizedValue”:”GREENGUARD Certified”,”value”:”GREENGUARD Certified”},{“name”:”Insulation Temp. Range”,”normalizedValue”:”-297 to 220 deg F”,”value”:”-297 Degrees F to 220 Degrees F”},{“name”:”Temp. Range”,”normalizedValue”:”-297 to 220 deg F”,”value”:”-297 Degrees to 220 Degrees F”},{“name”:”Wall Thickness – Insulation”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Insulation Approx. R Value”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Insulation Nominal I.D.”,”normalizedValue”:”3-1/2 in”,”value”:”3 1/2 in”},{“name”:”Approx. R Value”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Green Environmental Attribute”,”normalizedValue”:”Product Contributes To Reducing Energy Consumption”,”value”:”Product Contributes To Reducing Energy Consumption”},{“name”:”Insulation Body Material”,”normalizedValue”:”NBR, PVC”,”value”:”NBR/PVC”},{“name”:”Pipe Insulation Item”,”normalizedValue”:”Pipe Insulation”,”value”:”Pipe Insulation”},{“name”:”Fits Pipe Size – Pipe Insulation”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Insulation Type”,”normalizedValue”:”Unslit”,”value”:”Unslit”},{“name”:”Fits Pipe Size”,”normalizedValue”:”3 in”,”value”:”3 in”},{“name”:”Flame Spread Index”,”normalizedValue”:”32″,”value”:”32″},{“name”:”R Value”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Flexibility”,”normalizedValue”:”Flexible”,”value”:”Flexible”},{“name”:”Foam Cell Type”,”normalizedValue”:”Closed”,”value”:”Closed”},{“name”:”Smoke Developed Index”,”normalizedValue”:”57″,”value”:”57″},{“name”:”Green Environmental Properties”,”normalizedValue”:”No CFCs, Product Contributes to Reducing Energy Consumption”,”value”:”No CFCs, Product Contributes to Reducing Energy Consumption”},{“name”:”Installation Style”,”normalizedValue”:”Unslit”,”value”:”Unslit”},{“name”:”Plenum Rating”,”normalizedValue”:”Plenum Rated”,”value”:”Plenum Rated”},{“name”:”Clean Room Class”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Tube Style”,”normalizedValue”:”Unslit”,”value”:”Unslit”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “3″ x 6 ft. Pipe Insulation, 1/2″ Wall, K-Flex Usa, Mfr#: 6RX048348”