2W 3P 30A Hazardous Location Receptacle 600VAC

$5102,99

Receptacle, Circuit Breaker Amp Rating 50 A, Circuit Breaker Type FDB 600V AC, Current Rating 30 A, Fuse Protection Not Applicable, Fuse Type Not Applicable, Hazardous Location Specification Class I, Div 1 and 2, Group C, D, Class II, Div 1 and 2, Group F, G, Class III, Div 1 and 2, Locking Handle Yes, NEMA Enclosure Rating 3, 3R, 4, 4X, 7CD, 9FG, Number of Poles 3, Number of Wires 2, Voltage Rating 600V AC, Compatible Plug Manufacturer Part Number Not Applicable, Disconnect Switch No

9999 in stock

SKU: GRG7989852 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Receptacle”,”rank”:1,”value”:”Receptacle”},{“name”:”Voltage”,”normalizedValue”:”600V AC”,”rank”:2,”value”:”600V AC”},{“name”:”NEMA Rating”,”normalizedValue”:”3, 3R, 4, 4X, 7CD, 9FG”,”rank”:3,”value”:”3, 3R, 4, 4X, 7CD, 9FG”},{“name”:”Number of Wires”,”normalizedValue”:”2″,”rank”:4,”value”:”2″},{“name”:”Number of Poles”,”normalizedValue”:”3″,”rank”:5,”value”:”3″},{“name”:”Circuit Breaker Amp Rating”,”normalizedValue”:”50 A”,”rank”:6,”value”:”50 A”},{“name”:”Amps”,”normalizedValue”:”30″,”rank”:9,”value”:”30 A”},{“name”:”Material”,”normalizedValue”:”Copper-Free Aluminum”,”rank”:10,”value”:”Copper-Free Aluminum”},{“name”:”Standards”,”normalizedValue”:”E10784, E313360(EBR), E79132, UL 1010 (UL 1203), UL 1682, UL 894″,”value”:”E10784, E313360(EBR), E79132, UL 1010 (UL 1203), UL 1682, UL 894″},{“name”:”Circuit Breaker”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Hz”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Mounting Box”,”normalizedValue”:”Copperfree Aluminum”,”value”:”Copperfree Aluminum”},{“name”:”Hub Size”,”normalizedValue”:”3/4 in, 1-1/2 in”,”value”:”3/4 in, 1 1/2 in”},{“name”:”Finish”,”normalizedValue”:”Epoxy Powder Coated”,”value”:”Epoxy Powder Coated”},{“name”:”Housing Material”,”normalizedValue”:”Copper Free Aluminum”,”value”:”Copper-Free Aluminum”},{“name”:”Grounding”,”normalizedValue”:”Grounded”,”value”:”Grounded”},{“name”:”Disconnect Switch”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Handle Type”,”normalizedValue”:”Knob”,”value”:”Knob”},{“name”:”For Maximum Cable Diameter”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Resistance Properties”,”normalizedValue”:”Waterproof”,”value”:”Waterproof”},{“name”:”For Minimum Cable Diameter”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum Wire Size”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Hazardous Location Specification”,”normalizedValue”:”Class I, Div 1 and 2, Group C, D, Class II, Div 1 and 2, Group F, G, Class III, Div 1 and 2″,”value”:”Class I, Div 1 and 2, Group C, D, Class II, Div 1 and 2, Group F, G, Class III, Div 1 and 2″},{“name”:”Compatible Plug Manufacturer Part Number”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Circuit Breaker Type”,”normalizedValue”:”FDB 600V AC”,”value”:”FDB 600V AC”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”9FG, 3, 4X, 4, 3R, 7CD”,”value”:”3, 3R, 4, 4X, 7CD, 9FG”},{“name”:”Current Rating”,”normalizedValue”:”30 A”,”value”:”30 A”},{“name”:”Hub Type”,”normalizedValue”:”Feed Through”,”value”:”Feed Through”},{“name”:”Enclosure Lock Type”,”normalizedValue”:”Padlockable”,”value”:”Padlockable”},{“name”:”Compatible with Series”,”normalizedValue”:”Powertite”,”value”:”Powertite”},{“name”:”Includes Mounting Hardware”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Hub Diameter”,”normalizedValue”:”1-1/2 in”,”value”:”1.5 in”},{“name”:”Locking Handle”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Insulation Material”,”normalizedValue”:”Fiberglass-Reinforced Polyester”,”value”:”Fiberglass-Reinforced Polyester”},{“name”:”Housing Material Finish”,”normalizedValue”:”Epoxy Powder Coated”,”value”:”Epoxy Powder Coated”},{“name”:”Phase”,”normalizedValue”:”Single”,”value”:”Single”},{“name”:”Number of Gangs”,”normalizedValue”:”1″,”value”:”1″},{“name”:”For Environment”,”normalizedValue”:”Hazardous Location”,”value”:”Hazardous Location”},{“name”:”Wire Connection Type”,”normalizedValue”:”Quick-Disconnect Terminals”,”value”:”Quick-Disconnect Terminals”},{“name”:”Voltage Rating”,”normalizedValue”:”600V AC”,”value”:”600V AC”},{“name”:”Fuse Protection”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Contact Material”,”normalizedValue”:”Brass”,”value”:”Brass”},{“name”:”Includes”,”normalizedValue”:”Screw Cap”,”value”:”Screw Cap”},{“name”:”Fuse Type”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Amperage”,”normalizedValue”:”30, 60, 100 or 150″,”value”:”30, 60, 100 or 150″},{“name”:”Horsepower Ratings”,”normalizedValue”:”1, 2, 1.5, 10, 15, 20, 25, 3, 30, 40, 5, 50, 60, 7.5, 75″,”value”:”1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 60 or 75″},{“name”:”Materials and Finishes”,”normalizedValue”:”Receptacles, mounting box, covers and plug housings are copperfree (4/10 of 1% max.) aluminum with epoxy powder coat. Insulating blocks are fiber glass reinforced polyester.”,”value”:”Receptacles, mounting box, covers and plug housings are copperfree (4/10 of 1% max.) aluminum with epoxy powder coat. Insulating blocks are fiber glass reinforced polyester.”},{“name”:”Mounting Box Entries”,”normalizedValue”:”Feed-Thru”,”value”:”Feed-Thru”},{“name”:”Plug Cable Diameter”,”normalizedValue”:”30 Amp: 0.500 to 1.125#8221;, 60 Amp: 0.500 to 1.375#8221;, 100 Amp: 0.875 to 1.906#8221;, 150 Amp: 1.09#8221; to 2.187#8221;”,”value”:”30 Amp: 0.500 to 1.125#8221;, 60 Amp: 0.500 to 1.375#8221;, 100 Amp: 0.875 to 1.906#8221;, 150 Amp: 1.09#8221; to 2.187#8221;”},{“name”:”Hazardous Area Classification”,”normalizedValue”:”EBR Receptacle: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 7CD, 9FG?DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG”,”value”:”EBR Receptacle: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 7CD, 9FG?DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “2W 3P 30A Hazardous Location Receptacle 600VAC”