Description
[{“name”:”Item”,”normalizedValue”:”Switch Kit”,”rank”:1,”value”:”Switch Kit”},{“name”:”Standards”,”normalizedValue”:”IEC 60947-3″,”value”:”IEC 60947-3″},{“name”:”Height”,”normalizedValue”:”74 mm”,”value”:”74 mm”},{“name”:”Fire Resistance”,”normalizedValue”:”960°C IEC 60695-2-1″,”value”:”960°C IEC 60695-2-1″},{“name”:”Electrical Durability”,”normalizedValue”:”100000 cycles AC-21 || 30000 cycles DC-1 to 5″,”value”:”100000 cycles AC-21 || 30000 cycles DC-1 to 5″},{“name”:”[Icm] Rated Short-Circuit Making Capacity”,”normalizedValue”:”1 kA 400 V at Ipeak”,”value”:”1 kA 400 V at Ipeak”},{“name”:”Rotary Handle Padlocking”,”normalizedValue”:”1 to 3 padlocks 4-8 mm”,”value”:”1 to 3 padlocks 4-8 mm”},{“name”:”Making Capacity”,”normalizedValue”:”400 A 400 V AC-21A || 400 A 400 V AC-22A || 400 A 400 V AC-23A”,”value”:”400 A 400 V AC-21A || 400 A 400 V AC-22A || 400 A 400 V AC-23A”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-20-50°C”,”value”:”-20-50°C”},{“name”:”Device Composition”,”normalizedValue”:”switch || handle”,”value”:”switch || handle”},{“name”:”Suitability For Isolation”,”normalizedValue”:”yes”,”value”:”yes”},{“name”:”Mechanical Durability”,”normalizedValue”:”100,000 cycle”,”value”:”100000 cycles”},{“name”:”[Icw] Rated Short-Time Withstand Current”,”normalizedValue”:”480 A 400 V 1 s”,”value”:”480 A 400 V 1 s”},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”32 A”,”value”:”32 A”},{“name”:”Device Short Name”,”normalizedValue”:”VBF”,”value”:”VBF”},{“name”:”Rotary Handle Mounting Style”,”normalizedValue”:”direct”,”value”:”direct”},{“name”:”Width”,”normalizedValue”:”60 mm”,”value”:”60 mm”},{“name”:”Rated Conditional Short-Circuit Current”,”normalizedValue”:”10 kA 400 V 50 A aM || 10 kA 400 V 50 A gG”,”value”:”10 kA 400 V 50 A aM || 10 kA 400 V 50 A gG”},{“name”:”Breaking Capacity”,”normalizedValue”:”320 A 400 V AC-21A) || 320 A 400 V AC-22A) || 320 A 400 V AC-23A)”,”value”:”320 A 400 V AC-21A) || 320 A 400 V AC-22A) || 320 A 400 V AC-23A)”},{“name”:”Performance Level”,”normalizedValue”:”high performance”,”value”:”high performance”},{“name”:”Tightening Torque”,”normalizedValue”:”power circuit 2.1-2.1 N.m screw clamp terminals”,”value”:”power circuit 2.1-2.1 N.m screw clamp terminals”},{“name”:”Connections – Terminals”,”normalizedValue”:”power circuit screw clamp terminals 10-10 mm² solid || power circuit screw clamp terminals 6-6 mm² flexible – with cable end”,”value”:”power circuit screw clamp terminals 10-10 mm² solid || power circuit screw clamp terminals 6-6 mm² flexible – with cable end”},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”Fixing Mode”,”normalizedValue”:”by 4 screws handle”,”value”:”by 4 screws handle”},{“name”:”Product Name”,”normalizedValue”:”TeSys VARIO”,”value”:”TeSys VARIO”},{“name”:”Rated Operational Power In W”,”normalizedValue”:”11 kW 690 V AC-3) || 15 kW 690 V AC-23A) || 11 kW 400 to 415 V AC-3) || 15 kW 500 V AC-3) || 18.5 kW 500 V AC-23A) || 5.5 kW 230 to 240 V AC-3) || 7.5 kW 230 to 240 V AC-23A) || 15 kW 400 to 415 V AC-23A)”,”value”:”11 kW 690 V AC-3) || 15 kW 690 V AC-23A) || 11 kW 400 to 415 V AC-3) || 15 kW 500 V AC-3) || 18.5 kW 500 V AC-23A) || 5.5 kW 230 to 240 V AC-3) || 7.5 kW 230 to 240 V AC-23A) || 15 kW 400 to 415 V AC-23A)”},{“name”:”Range”,”normalizedValue”:”TeSys”,”value”:”TeSys”},{“name”:”Marking”,”normalizedValue”:”0 – 1″,”value”:”0 – 1″},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”Intermittent Duty Class”,”normalizedValue”:”30″,”value”:”30″},{“name”:”Mounting Support”,”normalizedValue”:”handle door || switch door”,”value”:”handle door || switch door”},{“name”:”Network Type”,”normalizedValue”:”DC || AC”,”value”:”DC || AC”},{“name”:”[Ue] Rated Operational Voltage”,”normalizedValue”:”690 V AC 50/60 Hz”,”value”:”690 V AC 50/60 Hz”},{“name”:”[Ith] Conventional Free Air Thermal Current”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP20 conforming to IEC 60529 || IP65″,”value”:”IP20 conforming to IEC 60529 || IP65″},{“name”:”Handle Front Plate Colour”,”normalizedValue”:”black”,”value”:”black”},{“name”:”Compatibility Code”,”normalizedValue”:”main switch disconnector”,”value”:”main switch disconnector”},{“name”:”Control Type”,”normalizedValue”:”rotary handle”,”value”:”rotary handle”},{“name”:”Product Certifications”,”normalizedValue”:”UL ||, CCC || GL || CSA UKCA”,”value”:”CCC || GL || CSA || UL || UKCA”},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”29 A AC-23 Ue: 400 V”,”value”:”29 A AC-23 Ue: 400 V”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”Handle Colour”,”normalizedValue”:”black”,”value”:”black”},{“name”:”Device Application”,”normalizedValue”:”preventive maintenance”,”value”:”preventive maintenance”},{“name”:”Product Or Component Type”,”normalizedValue”:”switch disconnector”,”value”:”switch disconnector”},{“name”:”Base Dimension”,”normalizedValue”:”60 mm x 60 mm”,”value”:”60 x 60 mm”},{“name”:”Mechanical Robustness”,”normalizedValue”:”vibrations 10 to 150 Hz 1 gn) IEC 60068-2-6 || shocks 11 ms 30 Gn) IEC 60068-2-27″,”value”:”vibrations 10 to 150 Hz 1 gn) IEC 60068-2-6 || shocks 11 ms 30 Gn) IEC 60068-2-27″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”8 kV”,”value”:”8 kV”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Czechia”,”value”:”Czechia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.