Description
[{“name”:”Item”,”normalizedValue”:”Selector Switch”,”rank”:9,”value”:”Selector Switch”},{“name”:”Bezel Material”,”normalizedValue”:”plastic”,”rank”:10,”value”:”plastic”},{“name”:”Standards”,”normalizedValue”:”EN/IEC 60947-5-1 || UL 508 || JIS C8201-5-1 || EN/IEC 60947-1 || CSA C22.2 No 14 || EN/IEC 60947-5-5 || JIS C 852 || JIS C8201-1″,”value”:”EN/IEC 60947-5-1 || UL 508 || JIS C8201-5-1 || EN/IEC 60947-1 || CSA C22.2 No 14 || EN/IEC 60947-5-5 || JIS C 852 || JIS C8201-1″},{“name”:”Series”,”normalizedValue”:”XB6″,”value”:”XB6″},{“name”:”Width”,”normalizedValue”:”18 mm”,”value”:”18 mm”},{“name”:”Height”,”normalizedValue”:”18 mm”,”value”:”18 mm”},{“name”:”Depth”,”normalizedValue”:”68 mm”,”value”:”68 mm”},{“name”:”Type Of Operator”,”normalizedValue”:”stay put”,”value”:”stay put”},{“name”:”Product Certifications”,”normalizedValue”:”CSA || UL || CCC || GOST”,”value”:”CSA || UL || CCC || GOST”},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”Positive Opening”,”normalizedValue”:”IEC, with EN 60947-5-1 appendix K”,”value”:”with EN/IEC 60947-5-1 appendix K”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”250 V 3)IEC 60947-1″,”value”:”250 V 3)IEC 60947-1″},{“name”:”Device Short Name”,”normalizedValue”:”XB6″,”value”:”XB6″},{“name”:”Contacts Material”,”normalizedValue”:”silver alloy”,”value”:”silver alloy (Ag/Ni)”},{“name”:”Operating Position”,”normalizedValue”:”any position”,”value”:”any position”},{“name”:”Nema Degree Of Protection”,”normalizedValue”:”NEMA 13 UL 50 || NEMA 4 UL 50 || NEMA 4X UL 50 || NEMA 13 CSA C22.2 No 94 || NEMA 4 CSA C22.2 No 94 || NEMA 4X CSA C22.2 No 94″,”value”:”NEMA 13 UL 50 || NEMA 4 UL 50 || NEMA 4X UL 50 || NEMA 13 CSA C22.2 No 94 || NEMA 4 CSA C22.2 No 94 || NEMA 4X CSA C22.2 No 94″},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP65 IEC 60529″,”value”:”IP65 IEC 60529″},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 || 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 || 0.22 A 125 V, DC-13, R300 EN/IEC 60947-5-1″,”value”:”3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 || 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 || 0.22 A 125 V, DC-13, R300 EN/IEC 60947-5-1″},{“name”:”Electrical Shock Protection Class”,”normalizedValue”:”class II IEC 61140″,”value”:”class II IEC 61140″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”4 kV EN/IEC 60947-1″,”value”:”4 kV EN/IEC 60947-1″},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”4 kV IEC 60947-1″,”value”:”4 kV IEC 60947-1″},{“name”:”Mounting Diameter”,”normalizedValue”:”16 mm”,”value”:”16 mm”},{“name”:”Product Or Component Type”,”normalizedValue”:”switch”,”value”:”complete selector switch”},{“name”:”Contact Operation”,”normalizedValue”:”slow-break”,”value”:”slow-break”},{“name”:”Shock Resistance”,”normalizedValue”:”30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27″,”value”:”30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27″},{“name”:”Shape Of Signaling Unit Head”,”normalizedValue”:”round”,”value”:”round”},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NO”,”value”:”(13-14)NO”},{“name”:”Connections – Terminals”,”normalizedValue”:”Faston connectors 2.8 x 0.5 mm”,”value”:”Faston connectors 2.8 x 0.5 mm”},{“name”:”Vibration Resistance”,”normalizedValue”:”+/- 3 mm 2-500 Hz)IEC 60068-2-6 || 5 gn 2-500 Hz)IEC 60068-2-6″,”value”:”+/- 3 mm 2-500 Hz)IEC 60068-2-6 || 5 gn 2-500 Hz)IEC 60068-2-6″},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Rated Operational Current”,”normalizedValue”:”3 A 120 V, AC-15, B300 IEC 60947-5-1; 1.5 A 240 V, AC-15, B300 IEC 60947-5-1; 0.1 A 250 V, DC-13, R300 IEC 60947-5-1; 0.22 A 125 V, DC-13, R300 IEC 60947-5-1″,”value”:”3 A 120 V, AC-15, B300 IEC 60947-5-1; 1.5 A 240 V, AC-15, B300 IEC 60947-5-1; 0.1 A 250 V, DC-13, R300 IEC 60947-5-1; 0.22 A 125 V, DC-13, R300 IEC 60947-5-1″},{“name”:”Mechanical Durability”,”normalizedValue”:”500,000 cycle”,”value”:”500000 cycles”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”250 V 3)EN/IEC 60947-1″,”value”:”250 V 3)EN/IEC 60947-1″},{“name”:”Electrical Reliability”,”normalizedValue”:”λ = 10exp(-8) 5 V 1 mA with confidence level of 90 % EN 60947-5-4″,”value”:”λ = 10exp(-8) 5 V 1 mA with confidence level of 90 % EN 60947-5-4″},{“name”:”Operator Profile”,”normalizedValue”:”black standard handle”,”value”:”black standard handle”},{“name”:”Short-Circuit Protection”,”normalizedValue”:”6 A cartridge fuse gG”,”value”:”6 A cartridge fuse gG”},{“name”:”Operator Position Information”,”normalizedValue”:”2 positions 60°”,”value”:”2 positions 60°”},{“name”:”Electrical Durability”,”normalizedValue”:”1000000 cycles, AC-15 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C”,”value”:”1000000 cycles, AC-15 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”1 NO + 1 NC”,”value”:”1 NO + 1 NC”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.