Description
[{“name”:”Pipe Size – Valves”,”normalizedValue”:”1-1/4 in”,”rank”:1,”value”:”1 1/4 in”},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”5-1/2 in”,”rank”:2,”value”:”5 1/2 in”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2″ Conduit with 18″ Leads”,”rank”:3,”value”:”1/2″ Conduit w/18″ Leads”},{“name”:”Valve Design”,”normalizedValue”:”2-Position, 2-Way”,”rank”:4,”value”:”2-Way/2-Position”},{“name”:”Voltage”,”normalizedValue”:”12V DC”,”rank”:5,”value”:”12V DC”},{“name”:”Item”,”normalizedValue”:”Fuel Gas Solenoid Valve”,”rank”:6,”value”:”Fuel Gas Solenoid Valve”},{“name”:”Orifice Dia.”,”normalizedValue”:”1-5/8 in”,”rank”:7,”value”:”1 5/8 in”},{“name”:”Valve Configuration”,”normalizedValue”:”Normally Closed”,”rank”:8,”value”:”Normally Closed”},{“name”:”Body Material – Valves”,”normalizedValue”:”Aluminum”,”rank”:9,”value”:”Aluminum”},{“name”:”Valve Ways and Positions”,”normalizedValue”:”2-Position, 2-Way”,”value”:”2-Way/2-Position”},{“name”:”Seal Material”,”normalizedValue”:”NBR”,”value”:”NBR”},{“name”:”Ambient Temp. Range”,”normalizedValue”:”-40 Degrees to 77 Degrees F”,”value”:”-40 Degrees to 77 Degrees F”},{“name”:”Media”,”normalizedValue”:”Fuel Gas”,”value”:”Fuel Gas”},{“name”:”Overall Height”,”normalizedValue”:”6-29/32 in”,”value”:”6 29/32 in”},{“name”:”Hz”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Application”,”normalizedValue”:”For On-Off Control of Fuel Gas in Commercial and Industrial Gas Burners”,”value”:”For On-Off Control of Fuel Gas in Commercial and Industrial Gas Burners”},{“name”:”Coil Insulation Class”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Overall Width”,”normalizedValue”:”5-13/32 in”,”value”:”5 13/32 in”},{“name”:”Watts”,”normalizedValue”:”35.1″,”value”:”35.1 W”},{“name”:”Seal Material – Valves”,”normalizedValue”:”NBR”,”value”:”NBR”},{“name”:”Coefficient of Volume”,”normalizedValue”:”32″,”value”:”32″},{“name”:”Coil Enclosure”,”normalizedValue”:”Watertight, Junction Box”,”value”:”General Purpose Junction Box and Watertight”},{“name”:”NEMA Rating”,”normalizedValue”:”1, 2, 3, 3S, 4, 4X”,”value”:”1, 2, 3, 3S, 4, 4X”},{“name”:”Overall Length”,”normalizedValue”:”5-5/16 in”,”value”:”5 5/16 in”},{“name”:”Environmental Rating – Valves”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”Standards”,”normalizedValue”:”UL and CSA for Safety Shutoff”,”value”:”UL and CSA for Safety Shutoff”},{“name”:”Pipe Size”,”normalizedValue”:”1 1/4″”,”value”:”1 1/4″”},{“name”:”Max. Operating Pressure Differential Water”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Min. Operating Pressure Differential”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Body Material”,”normalizedValue”:”Aluminum”,”value”:”Aluminum”},{“name”:”Max. Operating Pressure Differential”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Max. Operating Pressure Differential Air/Inert Gas”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Max. Fluid Temp.”,”normalizedValue”:”125 deg F”,”value”:”125 Degrees F”},{“name”:”Operation Type”,”normalizedValue”:”Pilot Operated”,”value”:”Pilot Operated”},{“name”:”Center L”e Pipe Center Size”,”normalizedValue”:”5-1/2 in”,”value”:”5 1/2″”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Valve Ways”,”normalizedValue”:”2-Way”,”value”:”2-Way”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”value”:”NPTF”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Ambient Temperature – Maximum”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Ambient Temperature – Minimum”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Wattage”,”normalizedValue”:”35.1 W”,”value”:”35.1 W”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”4, 4X, 3, 3S, 1, 2″,”value”:”1, 2, 3, 3S, 4, 4X”},{“name”:”Valve Type”,”normalizedValue”:”High Flow Gas Shut Off”,”value”:”High Flow Gas Shut Off”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Thread Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Actuator Type”,”normalizedValue”:”Double Solenoid”,”value”:”Double Solenoid”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”1-1/4 in”,”value”:”1 1/4 in”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Mounting Orientation”,”normalizedValue”:”Vertical”,”value”:”Vertical”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Configurable”,”value”:”Configurable”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Orifice Diameter”,”normalizedValue”:”1-5/8 in”,”value”:”1 5/8 in”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”value”:”NPTF”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”For Media”,”normalizedValue”:”Air, Inert Gases, Liquid Propane Gas, Natural Gas, Oxygen”,”value”:”Air, Inert Gases, Liquid Propane Gas, Natural Gas, Oxygen”},{“name”:”Environmental Rating”,”normalizedValue”:”Hazardous, Indoor, Outdoor”,”value”:”Hazardous, Indoor, Outdoor”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”5 psi”,”value”:”5 psi”},{“name”:”Includes Seal”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”32″,”value”:”32″},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Response Time”,”normalizedValue”:”1 sec”,”value”:”1 sec”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”125 deg F”,”value”:”125 Degrees F”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.