Description
[{“name”:”Pipe Size – Valves”,”normalizedValue”:”1/2 in”,”rank”:1,”value”:”1/2 in”},{“name”:”Center Line Pipe Center Size”,”normalizedValue”:”3-15/16 in”,”rank”:2,”value”:”3 15/16 in”},{“name”:”Electrical Connections”,”normalizedValue”:”1/2″ Conduit with 18″ Leads”,”rank”:3,”value”:”1/2″ Conduit w/18″ Leads”},{“name”:”Valve Design”,”normalizedValue”:”2-Position, 2-Way”,”rank”:4,”value”:”2-Way/2-Position”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:5,”value”:”120V AC”},{“name”:”Item”,”normalizedValue”:”Solenoid Valve”,”rank”:6,”value”:”Solenoid Valve”},{“name”:”Orifice Dia.”,”normalizedValue”:”5/8 in”,”rank”:7,”value”:”5/8 in”},{“name”:”Valve Configuration”,”normalizedValue”:”Normally Open”,”rank”:8,”value”:”Normally Open”},{“name”:”Body Material – Valves”,”normalizedValue”:”Stainless Steel”,”rank”:9,”value”:”Stainless Steel”},{“name”:”Min. Operating Pressure Differential”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Overall Length”,”normalizedValue”:”2-13/16 in”,”value”:”2 13/16 in”},{“name”:”NEMA Rating”,”normalizedValue”:”1, 2, 3, 3S, 4, 4X”,”value”:”1, 2, 3, 3S, 4, 4X”},{“name”:”Max. Operating Pressure Differential Light Oil”,”normalizedValue”:”100 psi”,”value”:”100 psi”},{“name”:”Max. Operating Pressure Differential Water”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Coil Insulation Class”,”normalizedValue”:”F”,”value”:”F”},{“name”:”Watts”,”normalizedValue”:”10.1″,”value”:”10.1 W”},{“name”:”Coil Enclosure”,”normalizedValue”:”Watertight No Junction Box”,”value”:”Watertight No Junction Box”},{“name”:”Overall Height”,”normalizedValue”:”4-11/16 in”,”value”:”4 11/16 in”},{“name”:”Media”,”normalizedValue”:”Air/Inert Gas, Light Oil and Water”,”value”:”Air/Inert Gas, Light Oil and Water”},{“name”:”Overall Width”,”normalizedValue”:”2-7/16 in”,”value”:”2 7/16 in”},{“name”:”Max. Operating Pressure Differential Air/Inert Gas”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Body Material”,”normalizedValue”:”Stainless steel”,”value”:”Stainless steel”},{“name”:”Seal Material”,”normalizedValue”:”NBR”,”value”:”NBR”},{“name”:”Coefficient of Volume”,”normalizedValue”:”3″,”value”:”3.0″},{“name”:”Max. Fluid Temp.”,”normalizedValue”:”180 deg F”,”value”:”180 Degrees F”},{“name”:”Pipe Size”,”normalizedValue”:”1/2″”,”value”:”1/2″”},{“name”:”Hz”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Valve Ways and Positions”,”normalizedValue”:”2-Position, 2-Way”,”value”:”2-Way/2-Position”},{“name”:”Application”,”normalizedValue”:”Air Compressors, Car Wash, Industrial Water Control, Laundry Equipment, Pumps”,”value”:”Air Compressors, Car Wash, Industrial Water Control, Laundry Equipment, Pumps”},{“name”:”Seal Material – Valves”,”normalizedValue”:”NBR”,”value”:”NBR”},{“name”:”IP Rating”,”normalizedValue”:”66″,”value”:”66″},{“name”:”Environmental Rating – Valves”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”Operation Type”,”normalizedValue”:”Pilot Operated”,”value”:”Pilot Operated”},{“name”:”Standards”,”normalizedValue”:”UL Listed”,”value”:”UL Listed”},{“name”:”Environmental Rating”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”Orifice Diameter”,”normalizedValue”:”5/8 in”,”value”:”5/8 in”},{“name”:”Outlet Connection Type”,”normalizedValue”:”NPTF”,”value”:”NPTF”},{“name”:”Operating Pressure Differential Water – Maximum”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Operating Pressure Differential Air/Inert Gas – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Valve Type”,”normalizedValue”:”High Flow”,”value”:”High Flow”},{“name”:”Frequency”,”normalizedValue”:”50 Hz, 60 Hz”,”value”:”50 Hz, 60 Hz”},{“name”:”Valve Starting Configuration”,”normalizedValue”:”Normally Open”,”value”:”Normally Open”},{“name”:”Response Time”,”normalizedValue”:”1 sec”,”value”:”1 sec”},{“name”:”Valve Positions”,”normalizedValue”:”2-Position”,”value”:”2-Position”},{“name”:”Operating Pressure Differential – Maximum”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Thread Type”,”normalizedValue”:”NPT”,”value”:”NPT”},{“name”:”Operating Pressure Differential – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Operating Pressure Differential Fuel Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Wattage”,”normalizedValue”:”10.1 W”,”value”:”10.1 W”},{“name”:”Operating Pressure Differential Light Oil – Maximum”,”normalizedValue”:”100 psi”,”value”:”100 psi”},{“name”:”Operating Pressure Differential Natural Gas – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”For Media”,”normalizedValue”:”Air, Inert Gases, Light Oil, Water”,”value”:”Air, Inert Gases, Light Oil, Water”},{“name”:”Mounting Orientation”,”normalizedValue”:”Vertical”,”value”:”Vertical”},{“name”:”Operating Pressure Differential Hot Water – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Valve Ways”,”normalizedValue”:”2-Way”,”value”:”2-Way”},{“name”:”Inlet Connection Type”,”normalizedValue”:”NPTF”,”value”:”NPTF”},{“name”:”Operating Pressure Differential Steam – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Steam – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Fuel Oil – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Water – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Operating Pressure Differential Fuel Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Includes Seal”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Pressure Differential Hot Water – Maximum”,”normalizedValue”:”Not Rated”,”value”:”Not Rated”},{“name”:”Operating Pressure Differential Natural Gas – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Fluid Temperature – Maximum”,”normalizedValue”:”180 deg F”,”value”:”180 Degrees F”},{“name”:”Operating Pressure Differential Fuel Oil – Maximum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Ambient Temperature – Maximum”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Coefficient of Volume (Cv)”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Operating Pressure Differential Light Oil – Minimum”,”normalizedValue”:”0 psi”,”value”:”0 psi”},{“name”:”Operating Pressure Differential Cryogenic Fluid – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Operating Pressure Differential Liquid CO2 – Minimum”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”4, 4X, 3, 3S, 1, 2″,”value”:”1, 2, 3, 3S, 4, 4X”},{“name”:”Ambient Temperature – Minimum”,”normalizedValue”:”14 deg F”,”value”:”14 Degrees F”},{“name”:”Operating Pressure Differential Air/Inert Gas – Maximum”,”normalizedValue”:”150 psi”,”value”:”150 psi”},{“name”:”Nominal Pipe Size”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Includes Coil”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Center L”e Pipe Center Size”,”normalizedValue”:”3-15/16 in”,”value”:”3 15/16″”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.