Description
[{“name”:”Jacket Color”,”normalizedValue”:”Black”,”rank”:6,”value”:”Black”},{“name”:”Jacket Material”,”normalizedValue”:”Non-halogenated, fire retardant polyolefin”,”rank”:7,”value”:”Non-halogenated, fire retardant polyolefin”},{“name”:”Capacitance”,”normalizedValue”:”75.8 pF/m | 23.104 pF/ft”,”value”:”75.8 pF/m | 23.104 pF/ft”},{“name”:”Flat Plate Crush Strength”,”normalizedValue”:”2 kg/mm | 111.995 lb/in”,”value”:”2 kg/mm | 111.995 lb/in”},{“name”:”Installation temperature”,”normalizedValue”:”-40 °C to +60 °C (-40 °F to +140 °F)”,”value”:”-40 °C to +60 °C (-40 °F to +140 °F)”},{“name”:”Inner Conductor Material”,”normalizedValue”:”Copper-clad aluminum wire”,”value”:”Copper-clad aluminum wire”},{“name”:”Number of Bends, typical”,”normalizedValue”:”50″,”value”:”50″},{“name”:”Diameter Over Jacket”,”normalizedValue”:”16.002 mm | 0.63 in”,”value”:”16.002 mm | 0.63 in”},{“name”:”Attenuation, Ambient Temperature”,”normalizedValue”:”20 °C | 68 °F”,”value”:”20 °C | 68 °F”},{“name”:”Average Power, Inner Conductor Temperature”,”normalizedValue”:”100 °C | 212 °F”,”value”:”100 °C | 212 °F”},{“name”:”EN50575 CPR Cable EuroClass Smoke Rating”,”normalizedValue”:”s1a”,”value”:”s1a”},{“name”:”ISO 9001:2015″,”normalizedValue”:”Designed, manufactured and/or distributed under this quality management system”,”value”:”Designed, manufactured and/or distributed under this quality management system”},{“name”:”dc Test Voltage”,”normalizedValue”:”4000 V”,”value”:”4000 V”},{“name”:”Smoke Index Test Method”,”normalizedValue”:”IEC 61034″,”value”:”IEC 61034″},{“name”:”Storage Temperature”,”normalizedValue”:”-40 °C to +60 °C (-40 °F to +140 °F)”,”value”:”-40 °C to +60 °C (-40 °F to +140 °F)”},{“name”:”dc Resistance, Outer Conductor”,”normalizedValue”:”2.69 ohms/km | 0.82 ohms/kft”,”value”:”2.69 ohms/km | 0.82 ohms/kft”},{“name”:”Toxicity Index Test Method”,”normalizedValue”:”IEC 60754-1 | IEC 60754-2″,”value”:”IEC 60754-1 | IEC 60754-2″},{“name”:”Insulation Resistance”,”normalizedValue”:”100000 MOhms-km”,”value”:”100000 MOhms-km”},{“name”:”Minimum Bend Radius, multiple Bends”,”normalizedValue”:”127 mm | 5 in”,”value”:”127 mm | 5 in”},{“name”:”Jacket Spark Test Voltage (rms)”,”normalizedValue”:”5000 V”,”value”:”5000 V”},{“name”:”Operating Frequency Band”,”normalizedValue”:”1 \” 8800 MHz”,”value”:”1 \” 8800 MHz”},{“name”:”Flexibility”,”normalizedValue”:”Standard”,”value”:”Standard”},{“name”:”Inner Conductor OD”,”normalizedValue”:”4.826 mm | 0.19 in”,”value”:”4.826 mm | 0.19 in”},{“name”:”Outer Conductor Material”,”normalizedValue”:”Corrugated copper”,”value”:”Corrugated copper”},{“name”:”Tensile Strength”,”normalizedValue”:”113 kg | 249.122 lb”,”value”:”113 kg | 249.122 lb”},{“name”:”Product Type”,”normalizedValue”:”Coaxial wireless cable”,”value”:”Coaxial wireless cable”},{“name”:”EN50575 CPR Cable EuroClass Droplets Rating”,”normalizedValue”:”d1″,”value”:”d1″},{“name”:”Diameter Over Dielectric”,”normalizedValue”:”12.954 mm | 0.51 in”,”value”:”12.954 mm | 0.51 in”},{“name”:”Product Series”,”normalizedValue”:”LDF4-50A”,”value”:”LDF4-50A”},{“name”:”UL/ETL Certification”,”normalizedValue”:”CATVR/CMR”,”value”:”CATVR/CMR”},{“name”:”Fire Retardancy Test Method”,”normalizedValue”:”NFPA 130-2010, UL 1666/CATVR/CMR”,”value”:”NFPA 130-2010 | UL 1666/CATVR/CMR”},{“name”:”Average Power, Ambient Temperature”,”normalizedValue”:”40 °C | 104 °F”,”value”:”40 °C | 104 °F”},{“name”:”Cable Impedance”,”normalizedValue”:”50 ohm ±1 ohm”,”value”:”50 ohm ±1 ohm”},{“name”:”Bending Moment”,”normalizedValue”:”3.8 N-m | 33.633 in lb”,”value”:”3.8 N-m | 33.633 in lb”},{“name”:”EN50575 CPR Cable EuroClass Fire Performance”,”normalizedValue”:”B2ca”,”value”:”B2ca”},{“name”:”Operating Temperature”,”normalizedValue”:”-40 °C to +60 °C (-40 °F to +140 °F)”,”value”:”-40 °C to +60 °C (-40 °F to +140 °F)”},{“name”:”Minimum Bend Radius, Single Bend”,”normalizedValue”:”50.8 mm | 2 in”,”value”:”50.8 mm | 2 in”},{“name”:”EN50575 CPR Cable EuroClass Acidity Rating”,”normalizedValue”:”a1″,”value”:”a1″},{“name”:”Ordering Note”,”normalizedValue”:”CommScope® standard product in Asia Pacific | CommScope® standard product in Europe, the Middle East, and Africa”,”value”:”CommScope® standard product in Asia Pacific | CommScope® standard product in Europe, the Middle East, and Africa”},{“name”:”dc Resistance, Inner Conductor”,”normalizedValue”:”1.48 ohms/km | 0.451 ohms/kft”,”value”:”1.48 ohms/km | 0.451 ohms/kft”},{“name”:”Nominal Size”,”normalizedValue”:”1/2 in”,”value”:”1/2 in”},{“name”:”Peak Power”,”normalizedValue”:”40 kW”,”value”:”40 kW”},{“name”:”Velocity”,”normalizedValue”:”0.88″,”value”:”0.88″},{“name”:”Inductance”,”normalizedValue”:”0.19 µH/m | 0.058 µH/ft”,”value”:”0.19 µH/m | 0.058 µH/ft”},{“name”:”Dielectric Material”,”normalizedValue”:”Foam PE”,”value”:”Foam PE”},{“name”:”Outer Conductor OD”,”normalizedValue”:”13.97 mm | 0.55 in”,”value”:”13.97 mm | 0.55 in”},{“name”:”Number of Bends, minimum”,”normalizedValue”:”15″,”value”:”15″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1000″,”value”:”1000″}]

Reviews
There are no reviews yet.