Description
[{“name”:”Height”,”normalizedValue”:”3.35 in”,”rank”:12,”value”:”3.35 in (85 mm)”},{“name”:”Width”,”normalizedValue”:”1.77 in”,”rank”:13,”value”:”1.77 in (45 mm)”},{“name”:”Depth”,”normalizedValue”:”3.62 in”,”rank”:14,”value”:”3.62 in (92 mm)”},{“name”:”Standards”,”normalizedValue”:”CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508; IEC 60335-1″,”value”:”CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508; IEC 60335-1″},{“name”:”Mechanical Durability”,”normalizedValue”:”15 Mcycles”,”value”:”15 Mcycles”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”450 A at 440 V for power circuit conforming to IEC 60947″,”value”:”450 A at 440 V for power circuit conforming to IEC 60947″},{“name”:”Product Or Component Type”,”normalizedValue”:”Contactor”,”value”:”Contactor”},{“name”:”Climatic Withstand”,”normalizedValue”:”IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat”,”value”:”IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat”},{“name”:”Compatibility Code”,”normalizedValue”:”LC1D”,”value”:”LC1D”},{“name”:”Average Impedance”,”normalizedValue”:”2 mOhm – Ith 40 A 50 Hz for power circuit”,”value”:”2 mOhm – Ith 40 A 50 Hz for power circuit”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit”,”value”:”10 A gG for signalling circuit conforming to IEC 60947-5-1; 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 40 A gG at Less than or Equal to 690 V coordination type 2 for power circuit”},{“name”:”Pollution Degree”,”normalizedValue”:”3″,”value”:”3″},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit”,”value”:”10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V for signalling circuit”,”value”:”17 V for signalling circuit”},{“name”:”Connections – Terminals”,”normalizedValue”:”Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) – cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) – cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1 to 10 mm²) – cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) – cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1.5 to 10 mm²) – cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) – cable stiffness: solid without cable end”,”value”:”Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminals 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: solid without cable end; Control circuit: screw clamp terminals 2 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: solid without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (2.5 to 10 mm²) – cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) – cable stiffness: flexible without cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1 to 10 mm²) – cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 2 0.00 to 0.01 in² (1.5 to 6 mm²) – cable stiffness: flexible with cable end; Power circuit: screw clamp terminals 1 0.00 to 0.02 in² (1.5 to 10 mm²) – cable stiffness: solid without cable end; Power circuit: screw clamp terminals 2 0.00 to 0.02 in² (2.5 to 10 mm²) – cable stiffness: solid without cable end”},{“name”:”Auxiliary Contacts Type”,”normalizedValue”:”Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1″,”value”:”Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1″},{“name”:”Tightening Torque”,”normalizedValue”:”Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat 6 mm; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat 6 mm; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2″,”value”:”Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat 6 mm; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat 6 mm; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2″},{“name”:”Contactor Application”,”normalizedValue”:”Resistive load; Motor control”,”value”:”Resistive load; Motor control”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC”,”value”:”Power circuit Less than or Equal to 690 V AC 25 to 400 Hz; Power circuit Less than or Equal to 300 V DC”},{“name”:”Mechanical Robustness”,”normalizedValue”:”Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms)”,”value”:”Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor closed 15 Gn for 11 ms); Shocks contactor open 8 Gn for 11 ms)”},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 10 MOhm for signalling circuit”,”value”:”Greater than 10 MOhm for signalling circuit”},{“name”:”Contact Compatibility”,”normalizedValue”:”M2″,”value”:”M2″},{“name”:”Mounting Support”,”normalizedValue”:”Plate; Rail”,”value”:”Plate; Rail”},{“name”:”Motor Power KW”,”normalizedValue”:”5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3); 11 kW at 380 to 400 V AC 50/60 Hz (AC-3); 11 kW at 415 to 440 V AC 50/60 Hz (AC-3); 15 kW at 500 V AC 50/60 Hz (AC-3); 15 kW at 660 to 690 V AC 50/60 Hz (AC-3); 5.5 kW at 400 V AC 50/60 Hz (AC-4); 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 15 kW at 500 V AC 50/60 Hz (AC-3e); 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e)”,”value”:”5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3); 11 kW at 380 to 400 V AC 50/60 Hz (AC-3); 11 kW at 415 to 440 V AC 50/60 Hz (AC-3); 15 kW at 500 V AC 50/60 Hz (AC-3); 15 kW at 660 to 690 V AC 50/60 Hz (AC-3); 5.5 kW at 400 V AC 50/60 Hz (AC-4); 5.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e); 11 kW at 380 to 400 V AC 50/60 Hz (AC-3e); 11 kW at 415 to 440 V AC 50/60 Hz (AC-3e); 15 kW at 500 V AC 50/60 Hz (AC-3e); 15 kW at 660 to 690 V AC 50/60 Hz (AC-3e)”},{“name”:”Product Certifications”,”normalizedValue”:”BV, CCC, CSA, DNV, GL, GOST, RINA, UL, LROS, UKCA”,”value”:”UL; BV; RINA; CCC; GL; GOST; DNV; LROS (Lloyds register of shipping); CSA; UKCA”},{“name”:”Inrush Power in VA”,”normalizedValue”:”70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))”,”value”:”70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))”},{“name”:”Power Dissipation Per Pole”,”normalizedValue”:”3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e”,”value”:”3.2 W AC-1; 1.25 W AC-3; 1.25 W AC-3e”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94″,”value”:”V1 conforming to UL 94″},{“name”:”Coil Technology”,”normalizedValue”:”Without built-in suppressor module”,”value”:”Without built-in suppressor module”},{“name”:”Permissible Ambient Air Temperature Around The Device”,”normalizedValue”:”-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating”,”value”:”-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating”},{“name”:”Fire Resistance”,”normalizedValue”:”1562°F (850°C) IEC 60695-2-1″,”value”:”1562°F (850°C) IEC 60695-2-1″},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA (for signalling circuit)”,”value”:”5 mA for signalling circuit”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947″,”value”:”6 kV IEC 60947″},{“name”:”Signalling Circuit Frequency”,”normalizedValue”:”25 to 400 Hz”,”value”:”25 to 400 Hz”},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors; 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors”,”value”:”3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors; 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors”},{“name”:”Electrical Durability”,”normalizedValue”:”1.65 Mcycles 25 A AC-3 Less than or Equal to 440 V; 1.4 Mcycles 40 A AC-1 Less than or Equal to 440 V; 1.65 Mcycles 25 A AC-3e Less than or Equal to 440 V”,”value”:”1.65 Mcycles 25 A AC-3 Less than or Equal to 440 V; 1.4 Mcycles 40 A AC-1 Less than or Equal to 440 V; 1.65 Mcycles 25 A AC-3e Less than or Equal to 440 V”},{“name”:”Operating Altitude”,”normalizedValue”:”0 to 9842.52 ft (0 to 3000 m)”,”value”:”0 to 9842.52 ft (0 to 3000 m)”},{“name”:”Rated Short Time Withstand Current”,”normalizedValue”:”240 A 104°F (40°C) – 10 s for power circuit; 380 A 104°F (40°C) – 1 s for power circuit; 50 A 104°F (40°C) – 10 min for power circuit; 120 A 104°F (40°C) – 1 min for power circuit; 100 A – 1 s for signalling circuit; 120 A – 500 ms for signalling circuit; 140 A – 100 ms for signalling circuit”,”value”:”240 A 104°F (40°C) – 10 s for power circuit; 380 A 104°F (40°C) – 1 s for power circuit; 50 A 104°F (40°C) – 10 min for power circuit; 120 A 104°F (40°C) – 1 min for power circuit; 100 A – 1 s for signalling circuit; 120 A – 500 ms for signalling circuit; 140 A – 100 ms for signalling circuit”},{“name”:”Hold-In Power Consumption in VA”,”normalizedValue”:”7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))”,”value”:”7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))”},{“name”:”Safety Reliability Level”,”normalizedValue”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″,”value”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″},{“name”:”Auxiliary Contact Composition”,”normalizedValue”:”1 NO + 1 NC”,”value”:”1 NO + 1 NC”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”3600 cyc/h 140°F (60°C)”,”value”:”3600 cyc/h 140°F (60°C)”},{“name”:”Protective Cover”,”normalizedValue”:”With”,”value”:”With”},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”Heat Dissipation”,”normalizedValue”:”2 to 3 W at 50/60 Hz”,”value”:”2 to 3 W at 50/60 Hz”},{“name”:”Pole Contact Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz standard”,”value”:”AC 50/60 Hz standard”},{“name”:”IRMS Rated Making Capacity”,”normalizedValue”:”140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947″,”value”:”140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947″},{“name”:”Overvoltage Category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”0.3 to 0.6 Uc -40 to 158°F (-40 to 70°C) drop-out AC 50/60 Hz; 0.8 to 1.1 Uc -40 to 140°F (-40 to 60°C) operational AC 50 Hz; 0.85 to 1.1 Uc -40 to 140°F (-40 to 60°C) operational AC 60 Hz; 1 to 1.1 Uc 140 to 158°F (60 to 70°C) operational AC 50/60 Hz”,”value”:”0.3 to 0.6 Uc -40 to 158°F (-40 to 70°C) drop-out AC 50/60 Hz; 0.8 to 1.1 Uc -40 to 140°F (-40 to 60°C) operational AC 50 Hz; 0.85 to 1.1 Uc -40 to 140°F (-40 to 60°C) operational AC 60 Hz; 1 to 1.1 Uc 140 to 158°F (60 to 70°C) operational AC 50/60 Hz”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-1, AC-3, AC-3e, AC-4″,”value”:”AC-3; AC-4; AC-1; AC-3e”},{“name”:”Protective Treatment”,”normalizedValue”:”THIEC 60068-2-30″,”value”:”THIEC 60068-2-30″},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL”,”value”:”Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL”},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP20 front face IEC 60529″,”value”:”IP20 front face IEC 60529″},{“name”:”Operating Time”,”normalizedValue”:”12 to 22 ms closing; 4 to 19 ms opening”,”value”:”12 to 22 ms closing; 4 to 19 ms opening”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”110 V AC 50/60 Hz”,”value”:”110 V AC 50/60 Hz”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact”,”value”:”1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact”},{“name”:”Rated Operational Current”,”normalizedValue”:”25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit”,”value”:”25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 40 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Indonesia”,”value”:”Indonesia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.