Description
[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Digital Multimeter”,”rank”:1,”value”:”Digital Multimeter”},{“name”:”Display Type”,”normalizedValue”:”Backlit LCD”,”rank”:2,”value”:”Backlit LCD”},{“name”:”Data Hold”,”normalizedValue”:”Yes”,”rank”:3,”value”:”Yes”},{“name”:”Instrument Counts”,”normalizedValue”:”6,000″,”rank”:4,”value”:”6,000″},{“name”:”Includes”,”normalizedValue”:”(1 Pair) Test Leads, 9V Battery (Installed), Quick Reference Guide”,”rank”:5,”value”:”(1 Pair) Test Leads, 9V Battery (Installed), Quick Reference Guide”},{“name”:”Standards”,”normalizedValue”:”ANSI/ISA S82.02.01, CSA C22.2-1010.1, UL, VDE”,”rank”:6,”value”:”ANSI/ISA S82.02.01, CSA C22.2-1010.1, UL, VDE”},{“name”:”Auto Power Off”,”normalizedValue”:”Yes”,”rank”:7,”value”:”Yes”},{“name”:”Data Logging”,”normalizedValue”:”Yes”,”rank”:8,”value”:”Yes”},{“name”:”Audible Continuity”,”normalizedValue”:”Yes”,”rank”:9,”value”:”Yes”},{“name”:”Diode Test”,”normalizedValue”:”Yes”,”rank”:10,”value”:”Yes”},{“name”:”Max. Ohms”,”normalizedValue”:”50 megohm”,”value”:”50 megohm”},{“name”:”Instrument Safety Rating”,”normalizedValue”:”CAT IV 600V”,”value”:”CAT IV 600V”},{“name”:”AC Response”,”normalizedValue”:”Average”,”value”:”Average”},{“name”:”Capacitance Range”,”normalizedValue”:”1 nF to 9999 uF”,”value”:”1 nF to 9999 uF”},{“name”:”Multimeter Style”,”normalizedValue”:”Full Size – General Features”,”value”:”Full Size – General Features”},{“name”:”Display”,”normalizedValue”:”Backlit LCD”,”value”:”Backlit LCD”},{“name”:”Instrument Frequency Counter Range”,”normalizedValue”:”0.01 Hz to 100 kHz”,”value”:”0.01 Hz to 100 kHz”},{“name”:”Calibration Certificate Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Basic DC Accuracy”,”normalizedValue”:”+/-0.30% of Reading + 1 Digit”,”value”:”+/-0.30% of Reading + 1 Digit”},{“name”:”Max. AC Amps”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”Limited Lifetime”,”value”:”Limited Lifetime”},{“name”:”Max. DC Amps”,”normalizedValue”:”10″,”value”:”10″},{“name”:”NIST Certification By”,”normalizedValue”:”Techni-Tool”,”value”:”Techni-Tool”},{“name”:”Series”,”normalizedValue”:”FLUKE (R) Fluke-77-IV”,”value”:”FLUKE (R) Fluke-77-IV”},{“name”:”Auto Ranging”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Duty Cycle”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Resistance Measurement Resolution”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Maximum DC Current Measurement”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Basic AC Voltage Accuracy”,”normalizedValue”:”+/-(2.0% + 2)”,”value”:”+/-(2.0% + 2)”},{“name”:”Batteries Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Bar Graph Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”NIST Certification By Manufacturer”,”normalizedValue”:”Techni-Tool”,”value”:”Techni-Tool”},{“name”:”Depth”,”normalizedValue”:”7.3 in”,”value”:”7.3 in”},{“name”:”Weight”,”normalizedValue”:”420 g”,”value”:”420 g”},{“name”:”Bluetooth Compatible”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”122 deg F”,”value”:”122 Degrees F”},{“name”:”Maximum Frequency Measurement”,”normalizedValue”:”100 kHz”,”value”:”100 kHz”},{“name”:”Maximum Capacitance Measurement”,”normalizedValue”:”9,999 uF”,”value”:”9,999 uF”},{“name”:”Capacitance Measurement Accuracy”,”normalizedValue”:”+/-(1.2% + 2)”,”value”:”+/-(1.2% + 2)”},{“name”:”Maximum Resistance Measurement”,”normalizedValue”:”50 megaohm”,”value”:”50 megaohm”},{“name”:”Maximum DC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Minimum AC Voltage Measurement”,”normalizedValue”:”0 V”,”value”:”0 V”},{“name”:”DC Current Measurement Resolution”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”DC Voltage Measurement Resolution”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Frequency Measurement Accuracy”,”normalizedValue”:”+/-(0.1% + 1)”,”value”:”+/-(0.1% + 1)”},{“name”:”Temperature Measurement Accuracy”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Minimum Frequency Measurement”,”normalizedValue”:”0.01 Hz”,”value”:”0.01 Hz”},{“name”:”Overall Width”,”normalizedValue”:”3-1/2 in”,”value”:”3.5 in”},{“name”:”Software Included”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Basic AC Current Accuracy”,”normalizedValue”:”2.5% + 2″,”value”:”2.5% + 2″},{“name”:”Maximum AC Current Measurement”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Maximum Storage Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Min-Max-Avg Button Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Waterproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Minimum Capacitance Measurement”,”normalizedValue”:”1 nF”,”value”:”1 nF”},{“name”:”Minimum Storage Temperature”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Fuse Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Capacitance Measurement Resolution”,”normalizedValue”:”1 nF”,”value”:”1 nF”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”14 deg F”,”value”:”14 Degrees F”},{“name”:”Maximum AC Voltage Measurement”,”normalizedValue”:”1,000 V”,”value”:”1,000 V”},{“name”:”Removable Screen”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Pulse Width”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Parameters Measured”,”normalizedValue”:”AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance”,”value”:”AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance”},{“name”:”Minimum/Maximum Memory”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Battery Access”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Computer Interface Connection Type”,”normalizedValue”:””,”value”:”None”},{“name”:”Dustproof”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Frequency Measurement Resolution”,”normalizedValue”:”0.01 Hz”,”value”:”0.01 Hz”},{“name”:”Temperature Measurement Resolution”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Basic DC Current Accuracy”,”normalizedValue”:”1.5% + 2″,”value”:”1.5% + 2″},{“name”:”Minimum DC Current Measurement”,”normalizedValue”:”0 mA”,”value”:”0 mA”},{“name”:”Battery Size”,”normalizedValue”:”9V”,”value”:”9V”},{“name”:”Current Leakage Testing”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Overall Height”,”normalizedValue”:”1.7 in”,”value”:”1.7 in”},{“name”:”Resistance Measurement Accuracy”,”normalizedValue”:”+/-0.5%”,”value”:”+/-0.5%”},{“name”:”Minimum DC Voltage Measurement”,”normalizedValue”:”0 V”,”value”:”0 V”},{“name”:”Thermal Imaging”,”normalizedValue”:”No”,”value”:”No”},{“name”:”AC Current Measurement Resolution”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Minimum AC Current Measurement”,”normalizedValue”:”0 mA”,”value”:”0 mA”},{“name”:”AC Response Calculation”,”normalizedValue”:”Average”,”value”:”Average”},{“name”:”Battery Chemistry”,”normalizedValue”:”Alkaline”,”value”:”Alkaline”},{“name”:”Battery Voltage”,”normalizedValue”:”9 V”,”value”:”9V”},{“name”:”Basic DC Voltage Accuracy”,”normalizedValue”:”+/-0.30% + 1 Digit”,”value”:”+/-0.30% + 1 Digit”},{“name”:”AC Voltage Measurement Resolution”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.