A145-30-11-80, A145 30 CONTACTOR 220/50 240/60

$1108,99

A145 30 CONTACTOR 220/50 240/60

Out of stock

SKU: GRG9283560 Category:

Description

[{“name”:”HP @ 3 Phase – 240V”,”normalizedValue”:”50 hp”,”value”:”50 hp”},{“name”:”Height”,”normalizedValue”:”196 mm”,”value”:”196 mm”},{“name”:”Depth”,”normalizedValue”:”160 mm”,”value”:”160 mm”},{“name”:”Coil Volts”,”normalizedValue”:”220 to 230V, 230 to 240V”,”value”:”220 to 230V, 230 to 240V”},{“name”:”HP @ 3 Phase – 208V”,”normalizedValue”:”40 hp”,”value”:”40 hp”},{“name”:”Aux. Contact Configuration”,”normalizedValue”:”1NO, 1NC”,”value”:”1NO/1NC”},{“name”:”Width”,”normalizedValue”:”111.5 mm”,”value”:”111.5 mm”},{“name”:”Hz”,”normalizedValue”:”50/60 Hz”,”value”:”50/60 Hz”},{“name”:”HP @ 3 Phase – 480V”,”normalizedValue”:”100 hp”,”value”:”100 hp”},{“name”:”Electrical Connection”,”normalizedValue”:”Bars”,”value”:”Bars”},{“name”:”Thermal Amperage”,”normalizedValue”:”250 A (at 40°C)”,”value”:”250 A (at 40°C)”},{“name”:”Rated Insulation Volts”,”normalizedValue”:”600/1000V”,”value”:”600/1000V”},{“name”:”Net Weight”,”normalizedValue”:”2.9 kg”,”value”:”2.9 kg”},{“name”:”Hold VA”,”normalizedValue”:”35 VA (at 50 Hz), 40 VA (at 60 Hz)”,”value”:”35 VA (at 50 Hz), 40 VA (at 60 Hz)”},{“name”:”Operating Time”,”normalizedValue”:”5 to 10 ms (Coil De-energization and NC Contact Closing), 9 to 13 ms (Coil De-energization and NO Contact Opening), 8 to 22 ms (Coil Energization and NC Contact Opening), 13 to 27 ms (Coil Energization and NO Contact Closing)”,”value”:”5 to 10 ms (Coil De-energization and NC Contact Closing), 9 to 13 ms (Coil De-energization and NO Contact Opening), 8 to 22 ms (Coil Energization and NC Contact Opening), 13 to 27 ms (Coil Energization and NO Contact Closing)”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”0.85 to 1.1 Uc”,”value”:”0.85 to 1.1 Uc”},{“name”:”Impulse Withstand Voltage”,”normalizedValue”:”8 kV”,”value”:”8 kV”},{“name”:”Mechanical Durability”,”normalizedValue”:”5 Mcycles”,”value”:”5 Mcycles”},{“name”:”Rated Voltage”,”normalizedValue”:”690V”,”value”:”690V”},{“name”:”Rated Short-Time Withstand Current”,”normalizedValue”:”1200 A (at 40°C for 10 s), 280 A (at 40°C for 15 min), 600 A (at 40°C for 1 min), 1800 A (at 40°C for 1 s), 800 A (at 40°C for 30 s)”,”value”:”1200 A (at 40°C for 10 s), 280 A (at 40°C for 15 min), 600 A (at 40°C for 1 min), 1800 A (at 40°C for 1 s), 800 A (at 40°C for 30 s)”},{“name”:”IP Rating”,”normalizedValue”:”IP20, IP00″,”value”:”IP00, IP20″},{“name”:”Working Height”,”normalizedValue”:”3,000 m”,”value”:”3000 m”},{“name”:”Max. Operating Watts”,”normalizedValue”:”75 kW (at 380/400V, 415V, 440V), 90 kW (at 500V), 110 kW (at 690V), 45 kW (at 220/230/240V)”,”value”:”75 kW (at 380/400V, 415V, 440V), 90 kW (at 500V), 110 kW (at 690V), 45 kW (at 220/230/240V)”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “A145-30-11-80, A145 30 CONTACTOR 220/50 240/60”