Description
[{“name”:”Item”,”normalizedValue”:”Electromechanical Timer”,”rank”:1,”value”:”Electromechanical Timer”},{“name”:”Voltage”,”normalizedValue”:”120V AC”,”rank”:2,”value”:”120V AC”},{“name”:”Amps”,”normalizedValue”:”40 A”,”rank”:3,”value”:”40 A”},{“name”:”Enclosure Type”,”normalizedValue”:”Plastic”,”rank”:4,”value”:”Plastic”},{“name”:”Min. Time Setting”,”normalizedValue”:”1 hr”,”rank”:5,”value”:”1 hr”},{“name”:”Max. Time Setting”,”normalizedValue”:”23 hr”,”rank”:6,”value”:”23 hr”},{“name”:”Contact Form”,”normalizedValue”:”DPST”,”rank”:7,”value”:”DPST”},{“name”:”Max. On/Off Cycles”,”normalizedValue”:”12″,”rank”:8,”value”:”12″},{“name”:”Depth”,”normalizedValue”:”3-13/16 in”,”value”:”3 13/16 in”},{“name”:”NEMA Rating”,”normalizedValue”:”3R”,”value”:”3R”},{“name”:”Day Skipper”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Number of Poles”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Mount”,”normalizedValue”:”Hole Wall”,”value”:”Hole Wall”},{“name”:”Contact HP @ 240V”,”normalizedValue”:”5 hp”,”value”:”5 hp”},{“name”:”Width”,”normalizedValue”:”5-1/2 in”,”value”:”5 1/2 in”},{“name”:”Description/Special Features”,”normalizedValue”:”3R Enclosures in Steel or Noncorrosive Plastic, Furnished with a Maximum of 12 Trippers, Has Adjustable Time Setting, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day”,”value”:”3R Enclosures in Steel or Noncorrosive Plastic, Furnished with a Maximum of 12 Trippers, Has Adjustable Time Setting, Manual On/Off Override does not Alter Program, Snap-out Timing Mechanism, Up to 12 On/Off Settings Per Day”},{“name”:”Height”,”normalizedValue”:”9-7/16 in”,”value”:”9 7/16 in”},{“name”:”Type”,”normalizedValue”:”24-Hour”,”value”:”24-Hour”},{“name”:”Extra Trippers”,”normalizedValue”:”2E054″,”value”:”2E054″},{“name”:”Finish”,”normalizedValue”:”Metal Enclosure has Gray Enamel”,”value”:”Metal Enclosure has Gray Enamel”},{“name”:”Contact HP @ 120V”,”normalizedValue”:”2 hp”,”value”:”2 hp”},{“name”:”Nominal Max. Time Setting”,”normalizedValue”:”24 hr”,”value”:”24 hr”},{“name”:”Number of Trippers Included”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Time Setting Range”,”normalizedValue”:”1 to 23 hr”,”value”:”1 hr. to 23 hr.”},{“name”:”Standards”,”normalizedValue”:”cCSAus, cULus”,”value”:”cCSAus, cULus”},{“name”:”Product Type”,”normalizedValue”:”Timer”,”value”:”Timer”},{“name”:”Operation Mode”,”normalizedValue”:”24 hr”,”value”:”24 hour”},{“name”:”Operating Temperature Max”,”normalizedValue”:”130°C”,”value”:”130°C”},{“name”:”Resistive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-240 VAC, 60 Hz”,”value”:”40 A, 120-240 VAC, 60 Hz”},{“name”:”UL Cerfication File Number”,”normalizedValue”:”UL917″,”value”:”UL917″},{“name”:”Power Consumption Max W”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”Pilot Duty Load Ratings”,”normalizedValue”:”1000 VA, 120-240 VAC, 60 Hz”,”value”:”1000 VA, 120-240 VAC, 60 Hz”},{“name”:”Inductive Load Ratings”,”normalizedValue”:”40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”,”value”:”40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”},{“name”:”Electronic Ballast Load Ratings”,”normalizedValue”:”16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC”,”value”:”16 A, 120 VAC; 16 A, 208 VAC; 16 A, 240 VAC; 16 A, 277 VAC”},{“name”:”Knockout Dimensions Back”,”normalizedValue”:”combination 1/2\” – 3/4\””,”value”:”(1) combination 1/2\” – 3/4\””},{“name”:”Input Voltage Ranges”,”normalizedValue”:”120 VAC, 60 Hz”,”value”:”120 VAC, 60 Hz”},{“name”:”Wiring Option”,”normalizedValue”:”Terminals”,”value”:”Terminals”},{“name”:”Product Width”,”normalizedValue”:”6-1/2 in, 165.1 mm”,”value”:”6 1/2 in; 165.1 mm”},{“name”:”Pilot Duty Load Ratings Ranges”,”normalizedValue”:”1000 VA, 120-240 VAC, 60 Hz”,”value”:”1000 VA, 120-240 VAC, 60 Hz”},{“name”:”Tungsten Load Ratings”,”normalizedValue”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 240 VAC, 60 Hz”},{“name”:”Market”,”normalizedValue”:”Commercial, Industrial”,”value”:”Commercial; Industrial”},{“name”:”Wire Size Max”,”normalizedValue”:”#8 AWG”,”value”:”#8 AWG”},{“name”:”Electronic Ballast Load Ratings Ranges”,”normalizedValue”:”16 A, 120-277 VAC”,”value”:”16 A, 120-277 VAC”},{“name”:”Wire Size Min”,”normalizedValue”:”#14 AWG”,”value”:”#14 AWG”},{“name”:”Has Manual Override CVL”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Knockout Dimensions Bottom”,”normalizedValue”:”(2) combination 1/2\” – 3/4\””,”value”:”(2) combination 1/2\” – 3/4\””},{“name”:”Skipper Wheel Operation Mode”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Number Of Circuits”,”normalizedValue”:”1″,”value”:”1″},{“name”:”UL Certification”,”normalizedValue”:”cULus”,”value”:”cULus”},{“name”:”CSA Certification”,”normalizedValue”:”cCSAus”,”value”:”cCSAus”},{“name”:”Applications”,”normalizedValue”:”Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control”,”value”:”Timing/Scheduling ON/OFF; Indoor Lighting Control; Outdoor Lighting Control”},{“name”:”Operating Temperature Min”,”normalizedValue”:”-40°C”,”value”:”-40°C”},{“name”:”Resistive Load Ratings”,”normalizedValue”:”40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”,”value”:”40 A, 240 VAC, 60 Hz; 40 A, 208 VAC, 60 Hz; 40 A, 120 VAC, 60 Hz”},{“name”:”Inductive Load Ratings Ranges”,”normalizedValue”:”40 A, 120-240 VAC, 60 Hz”,”value”:”40 A, 120-240 VAC, 60 Hz”},{“name”:”Switch Type”,”normalizedValue”:”DPST”,”value”:”DPST”},{“name”:”Minimum On Off Time”,”normalizedValue”:”1 hr”,”value”:”1 hour”},{“name”:”Timing Interval”,”normalizedValue”:”1 hr”,”value”:”1 hr”},{“name”:”Packaging Applications”,”normalizedValue”:”Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps”,”value”:”Indoor/Outdoor Lighting; Signs; Filters; Electric Fences; Fans; Conveyors; Pool Heaters; Blowers; Pumps”},{“name”:”Tungsten Load Ratings Ranges”,”normalizedValue”:”40 A, 120-240 VAC, 60 Hz”,”value”:”40 A, 120-240 VAC, 60 Hz”},{“name”:”Solutions”,”normalizedValue”:”Machinery \u0026 Pumps, Panel Integrators”,”value”:”Machinery \u0026 Pumps; Panel Integrators”},{“name”:”Product Height”,”normalizedValue”:”10 in, 254 mm”,”value”:”10 in; 254 mm”},{“name”:”Application Compatibilities”,”normalizedValue”:”LED, HID”,”value”:”LED; HID”},{“name”:”Product Depth”,”normalizedValue”:”4 in, 101.6 mm”,”value”:”4 in; 101.6 mm”},{“name”:”Motor Load Ratings”,”normalizedValue”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Maximum On Off Operations”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Maximum ON/OFF Operations”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Tungsten Range(s)”,”normalizedValue”:”40 A, 120-240 VAC, 60 Hz”,”value”:”40 A, 120-240 VAC, 60 Hz”},{“name”:”Minimum ON/OFF Times”,”normalizedValue”:”1 hr”,”value”:”1 hour”},{“name”:”Input Voltage Range(s)”,”normalizedValue”:”120 VAC, 60 Hz”,”value”:”120 VAC, 60 Hz”},{“name”:”Maximum Power Consumption (W)”,”normalizedValue”:”3 W”,”value”:”3 W”},{“name”:”Inductive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz”},{“name”:”Tungsten (NO)”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz”},{“name”:”Electronic Ballast”,”normalizedValue”:”16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC”,”value”:”16 A, 120 VAC, 16 A, 208 VAC, 16 A, 240 VAC, 16 A, 277 VAC”},{“name”:”Skipper Wheel”,”normalizedValue”:”Not Included”,”value”:”Not Included”},{“name”:”Motor Load Ratings Ranges”,”normalizedValue”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”,”value”:”2 HP, 24 FLA @ 120 VAC, 60 Hz; 5 HP, 28 FLA @ 240 VAC, 60 Hz”},{“name”:”Has Manual Override”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Product Height (in)”,”normalizedValue”:”10″,”value”:”10″},{“name”:”Operating Temperature Max (°F)”,”normalizedValue”:”130″,”value”:”130″},{“name”:”Pilot Duty (NO)”,”normalizedValue”:”1000 VA, 120-240 VAC, 60 Hz”,”value”:”1000 VA, 120-240 VAC, 60 Hz”},{“name”:”Features”,”normalizedValue”:”Manual Override”,”value”:”Manual Override”},{“name”:”Resistive”,”normalizedValue”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz”,”value”:”40 A, 120 VAC, 60 Hz, 40 A, 208 VAC, 60 Hz, 40 A, 240 VAC, 60 Hz”},{“name”:”Operating Temperature Min (°F)”,”normalizedValue”:”-40″,”value”:”-40″},{“name”:”Product Width (in)”,”normalizedValue”:”6.5″,”value”:”6.5″},{“name”:”Product Depth (in)”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Body Material”,”normalizedValue”:”Plastic”,”value”:”Plastic”},{“name”:”Overall Width”,”normalizedValue”:”6-1/2 in”,”value”:”6 1/2 in”},{“name”:”Compatible Lighting”,”normalizedValue”:”HID, LED”,”value”:”HID, LED”},{“name”:”Current Rating – Maximum”,”normalizedValue”:”40 A”,”value”:”40 A”},{“name”:”Indoor/Outdoor Usage”,”normalizedValue”:”Indoor, Outdoor”,”value”:”Indoor, Outdoor”},{“name”:”AC Voltage Rating”,”normalizedValue”:”120V AC”,”value”:”120V AC”},{“name”:”Number of Trippers – Maximum”,”normalizedValue”:”2″,”value”:”2″},{“name”:”Application”,”normalizedValue”:”Lighting”,”value”:”Lighting”},{“name”:”Mounting Style”,”normalizedValue”:”Surface”,”value”:”Surface”},{“name”:”Body Color”,”normalizedValue”:”Gray”,”value”:”Gray”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”130 deg F”,”value”:”130 Degrees F”},{“name”:”Horsepower @ 120V – Maximum”,”normalizedValue”:”2 HP”,”value”:”2 hp”},{“name”:”Overall Depth”,”normalizedValue”:”4 in”,”value”:”4 in”},{“name”:”Time Setting – Maximum”,”normalizedValue”:”24 hr”,”value”:”24 hr”},{“name”:”Time Setting – Minimum”,”normalizedValue”:”1 hr”,”value”:”1 hr”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”3R”,”value”:”3R”},{“name”:”Horsepower @ 240V – Maximum”,”normalizedValue”:”5 HP”,”value”:”5 hp”},{“name”:”Series”,”normalizedValue”:”T100″,”value”:”T100″},{“name”:”Overall Height”,”normalizedValue”:”10 in”,”value”:”10 in”},{“name”:”On/Off Cycles – Maximum”,”normalizedValue”:”12″,”value”:”12″},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Mexico”,”value”:”Mexico”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.