Belt, 48in, Roof, Exh, 28150 CFM, 3PH, 5HP, TE

$5137,99

Axial Upblast Roof Exhaust Fan, Includes Motor Yes, Includes Drive Package Yes, Drive Type Belt Drive, Base Diameter Not Applicable, Base Length 63 in, Base Width 63 in, Base Shape Square, Nameplate Voltage 230/460V AC, Phase 3, Motor Horsepower 5 hp, High-Efficiency Motor No, For High-Static Pressure Applications No, Motor Enclosure Totally Enclosed Fan Cooled, Blade Diameter 48 in, For Air Type Clean Air, Maximum Static Pressure 1/2 in wc, Maximum Inlet Air Temperature 104 Degrees F

9999 in stock

Description

[{“name”:”Item – Roof Ventilators”,”normalizedValue”:”Exhaust Ventilator”,”rank”:1,”value”:”Exhaust Ventilator”},{“name”:”Drive Type – Roof Ventilators”,”normalizedValue”:”Belt Drive”,”rank”:2,”value”:”Belt Drive”},{“name”:”Drive Package With Motor Included”,”normalizedValue”:”Yes”,”rank”:3,”value”:”Yes”},{“name”:”Base Size – Roof Ventilators”,”normalizedValue”:”63 in x 63 in”,”rank”:4,”value”:”63 in x 63 in”},{“name”:”Blade Dia.”,”normalizedValue”:”48 in”,”rank”:5,”value”:”48 in”},{“name”:”Voltage – Roof Ventilators”,”normalizedValue”:”230V AC/460V AC”,”rank”:6,”value”:”230V AC/460V AC”},{“name”:”Phase”,”normalizedValue”:”3″,”rank”:7,”value”:”3″},{“name”:”Motor HP”,”normalizedValue”:”5″,”rank”:8,”value”:”5 hp”},{“name”:”CFM @ 0.000-In. SP”,”normalizedValue”:”33,160″,”rank”:9,”value”:”33160″},{“name”:”Motor HP Range”,”normalizedValue”:”5 hp”,”value”:”5 hp”},{“name”:”Shaft Dia. Sheave End (In.)”,”normalizedValue”:”1-1/8″,”value”:”1.125 in”},{“name”:”Type”,”normalizedValue”:”Axial Upblast”,”value”:”Axial Upblast”},{“name”:”Speed Control”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Sones @ 0.125-In. SP @ 5 Ft.”,”normalizedValue”:”45 sones”,”value”:”45 sones”},{“name”:”Bearing Type”,”normalizedValue”:”Pillow Block”,”value”:”Ball Bearing Pillow Block”},{“name”:”Motor Voltage”,”normalizedValue”:”230/460″,”value”:”230/460″},{“name”:”Sones @ 0.250-In. SP @ 5 Ft.”,”normalizedValue”:”45 sones”,”value”:”45 sones”},{“name”:”Overall Dia. (In.)”,”normalizedValue”:”48″,”value”:”48 in”},{“name”:”Speed Controllable”,”normalizedValue”:”No”,”value”:”No”},{“name”:”CFM @ 0.375-In. SP”,”normalizedValue”:”27,380″,”value”:”27380″},{“name”:”Drive Package Included”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Fan RPM”,”normalizedValue”:”800″,”value”:”800″},{“name”:”Shaft Dia. Propeller End (In.)”,”normalizedValue”:”1-1/8″,”value”:”1.125 in”},{“name”:”CFM @ 0.500-In. SP”,”normalizedValue”:”25,000″,”value”:”25000″},{“name”:”Max. Inlet Temp. (Deg. F)”,”normalizedValue”:”70″,”value”:”70 Degrees F”},{“name”:”Housing Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Max. BHP”,”normalizedValue”:”4.4384″,”value”:”4.5 hp”},{“name”:”Mounting Location”,”normalizedValue”:”Roof”,”value”:”Roof”},{“name”:”Overall Height (In.)”,”normalizedValue”:”57-1/4″,”value”:”57.25 in”},{“name”:”Propeller Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”CFM Range”,”normalizedValue”:”33,160 to 25,000″,”value”:”33160-25000″},{“name”:”Max. Operating Amps”,”normalizedValue”:”6.7″,”value”:”6.7″},{“name”:”Motor Hz”,”normalizedValue”:”60″,”value”:”60″},{“name”:”Base Length (In.)”,”normalizedValue”:”63″,”value”:”63″},{“name”:”Assembled/Unassembled”,”normalizedValue”:”Assembled”,”value”:”Assembled”},{“name”:”Drive Type”,”normalizedValue”:”Belt Drive”,”value”:”Belt Drive”},{“name”:”CFM @ 0.250-In. SP”,”normalizedValue”:”29,290″,”value”:”29290″},{“name”:”RPM Range”,”normalizedValue”:”800″,”value”:”800″},{“name”:”Base Width (In.)”,”normalizedValue”:”63″,”value”:”63″},{“name”:”Base Height (In.)”,”normalizedValue”:”57-1/4″,”value”:”57.25 in”},{“name”:”CFM @ 0.125-In. SP”,”normalizedValue”:”30,900″,”value”:”30900″},{“name”:”Base Square Size – Roof Ventilators”,”normalizedValue”:”63 in x 63 in”,”value”:”63\” x 63\””},{“name”:”Item”,”normalizedValue”:”Axial Upblast Roof Exhaust Fan”,”value”:”Axial Upblast Roof Exhaust Fan”},{“name”:”Housing Length”,”normalizedValue”:”54 in”,”value”:”54 in”},{“name”:”Assembly”,”normalizedValue”:”Assembled”,”value”:”Assembled”},{“name”:”For Air Type”,”normalizedValue”:”Clean Air”,”value”:”Clean Air”},{“name”:”Includes Motor”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Nameplate Voltage”,”normalizedValue”:”230/460V AC”,”value”:”230/460V AC”},{“name”:”Motor Horsepower”,”normalizedValue”:”5 HP”,”value”:”5 hp”},{“name”:”Maximum Static Pressure”,”normalizedValue”:”0.5 in wc”,”value”:”1/2 in wc”},{“name”:”Exhaust Airflow @ 0.375 in SP”,”normalizedValue”:”27,380 cfm”,”value”:”27,380 cfm”},{“name”:”Exhaust Airflow @ 0.250 in SP”,”normalizedValue”:”29,290 cfm”,”value”:”29,290 cfm”},{“name”:”Motor Location”,”normalizedValue”:”Out of Airstream”,”value”:”Out of Airstream”},{“name”:”Series”,”normalizedValue”:”BRV8″,”value”:”BRV8″},{“name”:”Overall Depth”,”normalizedValue”:”63 in”,”value”:”63 in”},{“name”:”Exhaust Airflow @ 0.000 in SP”,”normalizedValue”:”33,160 cfm”,”value”:”33,160 cfm”},{“name”:”Overall Diameter”,”normalizedValue”:”48 in”,”value”:”48 in”},{“name”:”Damper Size”,”normalizedValue”:”54 in x 54 in”,”value”:”54 x 54 in”},{“name”:”Number of Speeds”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Motor Enclosure”,”normalizedValue”:”Totally Enclosed Fan Cooled”,”value”:”Totally Enclosed Fan Cooled”},{“name”:”Exhaust Airflow @ 0.100 in SP”,”normalizedValue”:”33,160 cfm”,”value”:”33,160 cfm”},{“name”:”Brake Horsepower”,”normalizedValue”:”4.5 HP”,”value”:”4 1/2 hp”},{“name”:”Base Length”,”normalizedValue”:”63 in”,”value”:”63 in”},{“name”:”Base Diameter”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Sound Level”,”normalizedValue”:”45 sones @ 0.125 in SP and 5 ft, 45 sones @ 0.250 in SP and 5 ft”,”value”:”45 sones @ 0.125 in SP and 5 ft, 45 sones @ 0.250 in SP and 5 ft”},{“name”:”Includes Drive Package”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Base Shape”,”normalizedValue”:”Square”,”value”:”Square”},{“name”:”Motor Speed”,”normalizedValue”:”800 RPM”,”value”:”800 RPM”},{“name”:”Housing Finish”,”normalizedValue”:”Galvanized”,”value”:”Galvanized”},{“name”:”Blade Finish”,”normalizedValue”:”Galvanized”,”value”:”Galvanized”},{“name”:”Maximum Inlet Air Temperature”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Propeller Shaft Diameter”,”normalizedValue”:”1-1/8 in”,”value”:”1 1/8 in”},{“name”:”High-Efficiency Motor”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Blade Diameter”,”normalizedValue”:”48 in”,”value”:”48 in”},{“name”:”Maximum Ambient Temperature”,”normalizedValue”:”104 deg F”,”value”:”104 Degrees F”},{“name”:”Housing Width”,”normalizedValue”:”54 in”,”value”:”54 in”},{“name”:”Application”,”normalizedValue”:”Designed for General Ventilation in Production or Warehouse Areas Where Efficient Quiet Air Flow is Required”,”value”:”Designed for General Ventilation in Production or Warehouse Areas Where Efficient Quiet Air Flow is Required”},{“name”:”Maximum Fan Speed”,”normalizedValue”:”800 RPM”,”value”:”800 RPM”},{“name”:”Exhaust Airflow @ 0.125 in SP”,”normalizedValue”:”30,900 cfm”,”value”:”30,900 cfm”},{“name”:”Base Height”,”normalizedValue”:”2 1/2 in”,”value”:”2 1/2 in”},{“name”:”Frequency”,”normalizedValue”:”60 Hz”,”value”:”60 Hz”},{“name”:”Exhaust Airflow @ 0.500 in SP”,”normalizedValue”:”25,000 cfm”,”value”:”25,000 cfm”},{“name”:”Mount Type”,”normalizedValue”:”Roof Curb”,”value”:”Roof Curb”},{“name”:”Power Source”,”normalizedValue”:”Electric Motor”,”value”:”Electric Motor”},{“name”:”Overall Height”,”normalizedValue”:”57-1/4 in”,”value”:”57 1/4 in”},{“name”:”For High-Static Pressure Applications”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Features”,”normalizedValue”:”Butterfly Damper Section, Damper Blades Open When Fan is Energized and Close Weathertight When Unit is Off, Dampers Rotate in Nylon Bearings on a Stainless Steel Axle, Ruggedly Constructed Steel Curb Cap Including Spun Venturi Section for Efficient Air Flow”,”value”:”Butterfly Damper Section, Damper Blades Open When Fan is Energized and Close Weathertight When Unit is Off, Dampers Rotate in Nylon Bearings on a Stainless Steel Axle, Ruggedly Constructed Steel Curb Cap Including Spun Venturi Section for Efficient Air Flow”},{“name”:”Blade Material”,”normalizedValue”:”Steel”,”value”:”Steel”},{“name”:”Number of Blades”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Airflow @ 0.000 in SP”,”normalizedValue”:”33,160 cfm”,”value”:”33,160 cfm”},{“name”:”Current”,”normalizedValue”:”6.7 A”,”value”:”6.7 A”},{“name”:”Overall Width”,”normalizedValue”:”63 in”,”value”:”63 in”},{“name”:”Base Width”,”normalizedValue”:”63 in”,”value”:”63 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Belt, 48in, Roof, Exh, 28150 CFM, 3PH, 5HP, TE”