120v 3pole CONTACTOR

$594,99

Out of stock

SKU: GRG509982156 Category:

Description

[{“name”:”Standards”,”normalizedValue”:”UL 508; EN 60947-4-1; EN 60947-5-1; IEC 60947-5-1; CSA C22.2 No 14; IEC 60947-4-1″,”value”:”UL 508; EN 60947-4-1; EN 60947-5-1; IEC 60947-5-1; CSA C22.2 No 14; IEC 60947-4-1″},{“name”:”Width”,”normalizedValue”:”2.17 in”,”value”:”2.17 in (55 mm)”},{“name”:”Depth”,”normalizedValue”:”4.69 in”,”value”:”4.69 in (119 mm)”},{“name”:”Height”,”normalizedValue”:”4.8 in”,”value”:”4.80 in (122 mm)”},{“name”:”Associated Fuse Rating”,”normalizedValue”:”10 A gG for control circuit conforming to IEC 60947-5-1; 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit”,”value”:”10 A gG for control circuit conforming to IEC 60947-5-1; 100 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 100 A gG at Less than or Equal to 690 V coordination type 2 for power circuit”},{“name”:”Control Circuit Voltage”,”normalizedValue”:”120 V AC 50/60 Hz”,”value”:”120 V AC 50/60 Hz”},{“name”:”Pole Contact Composition”,”normalizedValue”:”3 NO”,”value”:”3 NO”},{“name”:”Rated Operational Voltage”,”normalizedValue”:”Power circuit Less than or Equal to 690 V AC 25 to 400 Hz”,”value”:”Power circuit Less than or Equal to 690 V AC 25 to 400 Hz”},{“name”:”Power Dissipation Per Pole”,”normalizedValue”:”3.7 W AC-3; 9.6 W AC-1; 3.7 W AC-3e”,”value”:”3.7 W AC-3; 9.6 W AC-1; 3.7 W AC-3e”},{“name”:”Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV IEC 60947″,”value”:”6 kV IEC 60947″},{“name”:”Fire Resistance”,”normalizedValue”:”1562°F (850°C) IEC 60695-2-1″,”value”:”1562°F (850°C) IEC 60695-2-1″},{“name”:”Protective Cover”,”normalizedValue”:”With”,”value”:”With”},{“name”:”Mounting Support”,”normalizedValue”:”Plate; Rail”,”value”:”Plate; Rail”},{“name”:”Safety Reliability Level”,”normalizedValue”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″,”value”:”B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1″},{“name”:”IP Degree Of Protection”,”normalizedValue”:”IP2X IEC 60529; IP2X VDE 0106″,”value”:”IP2X IEC 60529; IP2X VDE 0106″},{“name”:”Coil Technology”,”normalizedValue”:”Without built-in bidirectional peak limiting diode suppressor”,”value”:”Without built-in bidirectional peak limiting diode suppressor”},{“name”:”Rated Operational Current”,”normalizedValue”:”80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit”,”value”:”80 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit; 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit”},{“name”:”Auxiliary Contacts Type”,”normalizedValue”:”Mirror contact 1 NC IEC 60947-4-1; Mechanically linked 1 NO + 1 NC IEC 60947-5-1″,”value”:”Mirror contact 1 NC IEC 60947-4-1; Mechanically linked 1 NO + 1 NC IEC 60947-5-1″},{“name”:”Mechanical Durability”,”normalizedValue”:”6000000 cycles”,”value”:”6000000 cycles”},{“name”:”Maximum Horse Power Rating”,”normalizedValue”:”3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA; 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL; 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA; 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL; 15 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA; 15 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL; 40 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA; 40 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL; 40 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA; 40 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL; 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA; 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL”,”value”:”3 hp at 115 V AC 60 Hz for 1 phase motors conforming to CSA; 3 hp at 115 V AC 60 Hz for 1 phase motors conforming to UL; 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA; 15 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL; 15 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA; 15 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to UL; 40 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to CSA; 40 hp at 460/480 V AC 60 Hz for 3 phase motors conforming to UL; 40 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to CSA; 40 hp at 575/600 V AC 60 Hz for 3 phase motors conforming to UL; 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to CSA; 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors conforming to UL”},{“name”:”Average Impedance”,”normalizedValue”:”1.5 mOhm – Ith 80 A 50 Hz for power circuit”,”value”:”1.5 mOhm – Ith 80 A 50 Hz for power circuit”},{“name”:”Permissible Ambient Air Temperature Around The Device”,”normalizedValue”:”23 to 140°F (-5 to 60°C); -40 to 158°F (-40 to 70°C) at Uc”,”value”:”23 to 140°F (-5 to 60°C); -40 to 158°F (-40 to 70°C) at Uc”},{“name”:”Connections – Terminals”,”normalizedValue”:”Control circuit: screw clamp terminal 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: solid without cable end; Control circuit: screw clamp terminal 2 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: solid without cable end; Control circuit: screw clamp terminal 1 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminal 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminal 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminal 2 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible with cable end; Power circuit: connector 1 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: solid with cable end; Power circuit: connector 2 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: solid with cable end; Power circuit: connector 1 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: flexible without cable end; Power circuit: connector 2 0.00 to 0.04 in² (2.5 to 25 mm²) – cable stiffness: flexible without cable end; Power circuit: connector 1 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: flexible with cable end; Power circuit: connector 2 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: flexible with cable end”,”value”:”Control circuit: screw clamp terminal 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: solid without cable end; Control circuit: screw clamp terminal 2 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: solid without cable end; Control circuit: screw clamp terminal 1 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminal 2 0.00 to 0.00 in² (1 to 2.5 mm²) – cable stiffness: flexible without cable end; Control circuit: screw clamp terminal 1 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible with cable end; Control circuit: screw clamp terminal 2 0.00 to 0.01 in² (1 to 4 mm²) – cable stiffness: flexible with cable end; Power circuit: connector 1 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: solid with cable end; Power circuit: connector 2 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: solid with cable end; Power circuit: connector 1 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: flexible without cable end; Power circuit: connector 2 0.00 to 0.04 in² (2.5 to 25 mm²) – cable stiffness: flexible without cable end; Power circuit: connector 1 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: flexible with cable end; Power circuit: connector 2 0.00 to 0.05 in² (2.5 to 35 mm²) – cable stiffness: flexible with cable end”},{“name”:”Operating Time”,”normalizedValue”:”12 to 26 ms closing; 4 to 19 ms opening”,”value”:”12 to 26 ms closing; 4 to 19 ms opening”},{“name”:”Non-Overlap Time”,”normalizedValue”:”1.5 ms on de-energisation between NC and NO contacts; 1.5 ms on energisation between NC and NO contacts”,”value”:”1.5 ms on de-energisation between NC and NO contacts; 1.5 ms on energisation between NC and NO contacts”},{“name”:”Contactor Application”,”normalizedValue”:”Motor control; Resistive load”,”value”:”Motor control; Resistive load”},{“name”:”Tightening Torque”,”normalizedValue”:”Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminal flat 6 mm; Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminal Philips No 2; Power circuit 44.25 lbf.in (5 N.m) screw clamp terminal flat 6 mm; Power circuit 44.25 lbf.in (5 N.m) screw clamp terminal flat 8 mm; Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminal pozidriv No 2″,”value”:”Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminal flat 6 mm; Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminal Philips No 2; Power circuit 44.25 lbf.in (5 N.m) screw clamp terminal flat 6 mm; Power circuit 44.25 lbf.in (5 N.m) screw clamp terminal flat 8 mm; Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminal pozidriv No 2″},{“name”:”Product Or Component Type”,”normalizedValue”:”Contactor”,”value”:”Contactor”},{“name”:”Poles Description”,”normalizedValue”:”3P”,”value”:”3P”},{“name”:”Minimum Switching Current”,”normalizedValue”:”5 mA (for control circuit)”,”value”:”5 mA for control circuit”},{“name”:”Conventional Free Air Thermal Current”,”normalizedValue”:”10 A (at 140°F (60°C)) for control circuit; 80 A (at 140°F (60°C)) for power circuit”,”value”:”10 A (at 140°F (60°C)) for control circuit; 80 A (at 140°F (60°C)) for power circuit”},{“name”:”Minimum Switching Voltage”,”normalizedValue”:”17 V for control circuit”,”value”:”17 V for control circuit”},{“name”:”Rated Breaking Capacity”,”normalizedValue”:”900 A at 440 V for power circuit conforming to IEC 60947″,”value”:”900 A at 440 V for power circuit conforming to IEC 60947″},{“name”:”IRMS Rated Making Capacity”,”normalizedValue”:”140 A AC for control circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947″,”value”:”140 A AC for control circuit conforming to IEC 60947-5-1; 900 A at 440 V for power circuit conforming to IEC 60947″},{“name”:”Hold-In Power Consumption in VA”,”normalizedValue”:”13 VA 50 Hz cos phi 0.3 (at 68°F (20°C)); 15 VA 60 Hz cos phi 0.3 (at 68°F (20°C))”,”value”:”13 VA 50 Hz cos phi 0.3 (at 68°F (20°C)); 15 VA 60 Hz cos phi 0.3 (at 68°F (20°C))”},{“name”:”Maximum Operating Rate”,”normalizedValue”:”3600 cyc/h 140°F (60°C)”,”value”:”3600 cyc/h 140°F (60°C)”},{“name”:”Operating Altitude”,”normalizedValue”:”9842.52 ft (3000 m) without derating”,”value”:”9842.52 ft (3000 m) without derating”},{“name”:”Utilisation Category”,”normalizedValue”:”AC-1, AC-3, AC-3e, AC-4, AC-2″,”value”:”AC-3; AC-2; AC-4; AC-1; AC-3e”},{“name”:”Flame Retardance”,”normalizedValue”:”V1 conforming to UL 94″,”value”:”V1 conforming to UL 94″},{“name”:”Climatic Withstand”,”normalizedValue”:”IACS E10 exposure to damp heat”,”value”:”IACS E10 exposure to damp heat”},{“name”:”Product Certifications”,”normalizedValue”:”GOST; LROS (pending); UL; CCC; RINA; CSA; BV; GL; DNV; UKCA”,”value”:”GOST; LROS (pending); UL; CCC; RINA; CSA; BV; GL; DNV; UKCA”},{“name”:”Heat Dissipation”,”normalizedValue”:”4 to 5 W at 50/60 Hz for control circuit”,”value”:”4 to 5 W at 50/60 Hz for control circuit”},{“name”:”Mechanical Robustness”,”normalizedValue”:”Shocks contactor opened 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms); Vibrations contactor opened 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz)”,”value”:”Shocks contactor opened 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms); Vibrations contactor opened 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz)”},{“name”:”Control Circuit Voltage Limits”,”normalizedValue”:”0.3 to 0.6 Uc 140°F (60°C) drop-out AC 50/60 Hz; 0.8 to 1.1 Uc 140°F (60°C) operational AC 50 Hz; 0.85 to 1.1 Uc 140°F (60°C) operational AC 60 Hz”,”value”:”0.3 to 0.6 Uc 140°F (60°C) drop-out AC 50/60 Hz; 0.8 to 1.1 Uc 140°F (60°C) operational AC 50 Hz; 0.85 to 1.1 Uc 140°F (60°C) operational AC 60 Hz”},{“name”:”Control Circuit Type”,”normalizedValue”:”AC 50/60 Hz”,”value”:”AC 50/60 Hz”},{“name”:”Rated Insulation Voltage”,”normalizedValue”:”Control circuit 600 V CSA; Control circuit 600 V UL; Power circuit 600 V CSA; Power circuit 600 V UL; Control circuit 690 V IEC 60947-1; Power circuit 690 V IEC 60947-1″,”value”:”Control circuit 600 V CSA; Control circuit 600 V UL; Power circuit 600 V CSA; Power circuit 600 V UL; Control circuit 690 V IEC 60947-1; Power circuit 690 V IEC 60947-1″},{“name”:”Motor Power KW”,”normalizedValue”:”22 kW at 380 to 400 V AC 50/60 Hz (AC-3); 25 kW at 415 V AC 50/60 Hz (AC-3); 30 kW at 440 V AC 50/60 Hz (AC-3); 30 kW at 500 V AC 50/60 Hz (AC-3); 33 kW at 660 to 690 V AC 50/60 Hz (AC-3); 15 kW at 220 to 230 V AC 50/60 Hz (AC-3); 11 kW at 400 V AC 50/60 Hz (AC-4)”,”value”:”22 kW at 380 to 400 V AC 50/60 Hz (AC-3); 25 kW at 415 V AC 50/60 Hz (AC-3); 30 kW at 440 V AC 50/60 Hz (AC-3); 30 kW at 500 V AC 50/60 Hz (AC-3); 33 kW at 660 to 690 V AC 50/60 Hz (AC-3); 15 kW at 220 to 230 V AC 50/60 Hz (AC-3); 11 kW at 400 V AC 50/60 Hz (AC-4)”},{“name”:”Overvoltage Category”,”normalizedValue”:”III”,”value”:”III”},{“name”:”Inrush Power in VA”,”normalizedValue”:”140 VA cos phi 0.75 (at 68°F (20°C)); 160 VA cos phi 0.75 (at 68°F (20°C))”,”value”:”140 VA cos phi 0.75 (at 68°F (20°C)); 160 VA cos phi 0.75 (at 68°F (20°C))”},{“name”:”Compatibility Code”,”normalizedValue”:”LC1D”,”value”:”LC1D”},{“name”:”Insulation Resistance”,”normalizedValue”:”Greater than 10 MOhm for control circuit”,”value”:”Greater than 10 MOhm for control circuit”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Thailand”,”value”:”Thailand”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “120v 3pole CONTACTOR”