Air velocity transmitter, 6″ (152.4 mm) probe length.

$725,99

Air Velocity Transmitter, Digital Display Screen Type No Display, Response Time 1.5 sec, Maximum Operating Temperature 140 Degrees F, Probe Diameter 0.5 in, Maximum Output Signal 20 mA, Maximum Temperature Measured 212 Degrees F, Maximum Velocity Measured 15,000 fpm, Minimum Operating Temperature 32 Degrees F, Minimum Temperature Measured -40 Degrees F, Minimum Velocity Measured 250 fpm, Minimum Output Signal 4 mA, Pressure Limit 100 psi, Air Velocity Accuracy +/-3 Percent (32 to 122 Degrees F)

9999 in stock

SKU: GRG5614917 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Air Velocity Transmitter”,”rank”:1,”value”:”Air Velocity Transmitter”},{“name”:”Air Velocity Accuracy”,”normalizedValue”:”+/-3% (32 to 122 Degrees F)”,”rank”:2,”value”:”+/-3% (32 to 122 Degrees F)”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”1″,”rank”:4,”value”:”1″},{“name”:”Velocity Ranges”,”normalizedValue”:”FPM: 250, 500, 1000, 2000, 3000, 5000, 10000, 15000″,”value”:”FPM: 250, 500, 1000, 2000, 3000, 5000, 10000, 15000″},{“name”:”Max. Pressure (PSI)”,”normalizedValue”:”100″,”value”:”100 psi”},{“name”:”Velocity Accuracy”,”normalizedValue”:”3% FS Process gas: 32 to 122 Degrees F (0 to 50 Degrees C); 4% FS Process gas: -40 to 32 Degrees F \u0026 122 to 212 Degrees F (-40 to 0 Degrees C \u0026 50 to 100 Degrees C)”,”value”:”3% FS Process gas: 32 to 122 Degrees F (0 to 50 Degrees C); 4% FS Process gas: -40 to 32 Degrees F \u0026 122 to 212 Degrees F (-40 to 0 Degrees C \u0026 50 to 100 Degrees C)”},{“name”:”Dia. (In.)”,”normalizedValue”:”1/2″,”value”:”1/2 in”},{“name”:”Probe Length (In.)”,”normalizedValue”:”6″,”value”:”6 in”},{“name”:”Output”,”normalizedValue”:”4 to 20ma DC”,”value”:”4 to 20ma DC”},{“name”:”Operating Temp.”,”normalizedValue”:”Process: -40 to 212 Degrees F (-40 to 100 Degrees C) Ambient: 32 to 140 Degrees F (0 to 60 Degrees C)”,”value”:”Process: -40 to 212 Degrees F (-40 to 100 Degrees C) Ambient: 32 to 140 Degrees F (0 to 60 Degrees C)”},{“name”:”Response Time (Sec.)”,”normalizedValue”:”1.5 Seconds to 95% of Final Value (Output Filter Set to Minimum)”,”value”:”1.5 Seconds to 95% of Final Value (Output Filter Set to Minimum)”},{“name”:”Power Required”,”normalizedValue”:”10 to 16 VAC 1.5A Rating Required on Supply Due to Initial Power Surge Drawn by Transmitter, 12 to 35 VDC”,”value”:”10 to 16 VAC 1.5A Rating Required on Supply Due to Initial Power Surge Drawn by Transmitter, 12 to 35 VDC”},{“name”:”Display Type”,”normalizedValue”:””,”value”:”None”},{“name”:”Response Time”,”normalizedValue”:”1.5 sec”,”value”:”1.5 sec”},{“name”:”Minimum Operating Temperature”,”normalizedValue”:”32 deg F”,”value”:”32 Degrees F”},{“name”:”Maximum AC Voltage Required”,”normalizedValue”:”16 V”,”value”:”16 V”},{“name”:”Minimum Temperature Measured”,”normalizedValue”:”-40 deg F”,”value”:”-40 Degrees F”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”1 yr”,”value”:”1 yr”},{“name”:”Pressure Limit”,”normalizedValue”:”100 psi”,”value”:”100 psi”},{“name”:”Maximum Probe Length”,”normalizedValue”:”6 in”,”value”:”6 in”},{“name”:”Maximum Temperature Measured”,”normalizedValue”:”212 deg F”,”value”:”212 Degrees F”},{“name”:”Minimum DC Voltage Required”,”normalizedValue”:”12 V”,”value”:”12 V”},{“name”:”Minimum Velocity Measured”,”normalizedValue”:”250 fpm”,”value”:”250 fpm”},{“name”:”Maximum Operating Temperature”,”normalizedValue”:”140 deg F”,”value”:”140 Degrees F”},{“name”:”Minimum Output Signal”,”normalizedValue”:”4 mA”,”value”:”4 mA”},{“name”:”Probe Diameter”,”normalizedValue”:”1/2 in”,”value”:”0.5 in”},{“name”:”Minimum AC Voltage Required”,”normalizedValue”:”10 V”,”value”:”10 V”},{“name”:”Digital Display Screen Type”,”normalizedValue”:”No Display”,”value”:”No Display”},{“name”:”Maximum Output Signal”,”normalizedValue”:”20 mA”,”value”:”20 mA”},{“name”:”Maximum DC Voltage Required”,”normalizedValue”:”35 V”,”value”:”35 V”},{“name”:”Maximum Velocity Measured”,”normalizedValue”:”15,000 fpm”,”value”:”15,000 fpm”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Air velocity transmitter, 6″ (152.4 mm) probe length.”