Description
[{“name”:”Item”,”normalizedValue”:”Trk Mnt,20A,Rly/Current Switch Adjstable”,”rank”:1,”value”:”Trk Mnt,20A,Rly/Current Switch Adjstable”},{“name”:”Width”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Type”,”normalizedValue”:”Internal with contact status”,”value”:”Internal w/ contact status”},{“name”:”Override Switch”,”normalizedValue”:”Yes”,”value”:”Yes”},{“name”:”Operating Temperature”,”normalizedValue”:”-30 to 140° F”,”value”:”-30 to 140° F”},{“name”:”Resistive”,”normalizedValue”:”20 A”,”value”:”20 Amp”},{“name”:”Coil Voltage Input”,”normalizedValue”:”24 Vac/dc ; 50-60 Hz Drop Out – 3 Vac / 3.8 Vdc Pull In – 18 Vac / 22 Vdc”,”value”:”24 Vac/dc ; 50-60 Hz Drop Out – 3 Vac / 3.8 Vdc Pull In – 18 Vac / 22 Vdc”},{“name”:”Gold Flash”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Relay Status”,”normalizedValue”:”Red LED On – Activated”,”value”:”Red LED On – Activated”},{“name”:”Dimensions”,”normalizedValue”:”2.95\”H x 4.00\”W x 1.25\”D1/1.75\”D2″,”value”:”2.95\”H x 4.00\”W x 1.25\”D1/1.75\”D2″},{“name”:”Contact Ratings”,”normalizedValue”:”20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac”,”value”:”20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1,110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac”},{“name”:”Contact Type”,”normalizedValue”:”SPST”,”value”:”SPST”},{“name”:”Threshold”,”normalizedValue”:”Adjustable”,”value”:”Adjustable”},{“name”:”Series”,”normalizedValue”:”RIBMX24 Series”,”value”:”RIBMX24 Series”},{“name”:”Coil Current”,”normalizedValue”:”50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc”,”value”:”50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc”},{“name”:”Expected Relay Life”,”normalizedValue”:”10 million cycles minimum mechanical”,”value”:”10 million cycles minimum mechanical”},{“name”:”Approvals”,”normalizedValue”:”UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE”,”value”:”UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE”},{“name”:”Humidity Range”,”normalizedValue”:”5 to 95% (noncondensing)”,”value”:”5 to 95% (noncondensing)”},{“name”:”Track Mount”,”normalizedValue”:”4.000\”, MT4 Mounting Track Sold Separately”,”value”:”4.000\”, MT4 Mounting Track Sold Separately”},{“name”:”Sensor Output”,”normalizedValue”:”Solid State Contact 30 Vac/dc, 0.4 Amp”,”value”:”Solid State Contact 30 Vac/dc, 0.4 Amp”},{“name”:”Operate Time”,”normalizedValue”:”18ms”,”value”:”18ms”},{“name”:”Sensing Range”,”normalizedValue”:”0.5 to 20 A”,”value”:”.50-20 Amps”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”United States”,”value”:”United States”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews
There are no reviews yet.