Cable Pull Switch, 10A, Left, 1NO+1NC

$470,99

Emergency Cable Pull Switch, Switch Function Maintained, Mounting Style Single End, AC Contact Rating 3 A @ 240 V, Contact Form 1NO/1NC, Push Button Reset, Max. Cable Span 165 ft, Operating Force Not Applicable, NEMA Rating 1, 12, 4, Indicator No Indicator, Cable Connection Location Left, Thermal Amperage 10 A, Length 9.0 in, Width 9.02 in, Depth 4.13 in, Switching Ability Single Cable, DC Contact Rating 0.27 A @ 250 V, Min. Current Not Applicable, Case Material Zamak, Wiring Entry 1/2 in NPT

9999 in stock

SKU: GRG2707336 Category:

Description

[{“name”:”Item”,”normalizedValue”:”Emergency Cable Pull Switch”,”rank”:1,”value”:”Emergency Cable Pull Switch”},{“name”:”Switch Function”,”normalizedValue”:”Maintained”,”rank”:2,”value”:”Maintained”},{“name”:”Mounting Style”,”normalizedValue”:”Single End”,”rank”:3,”value”:”Single End”},{“name”:”AC Contact Rating”,”normalizedValue”:”3 A @ 240 V”,”rank”:4,”value”:”3 A @ 240 V”},{“name”:”Contact Form”,”normalizedValue”:”1NO/1NC”,”rank”:5,”value”:”1NO/1NC”},{“name”:”Reset”,”normalizedValue”:”Push Button”,”rank”:6,”value”:”Push Button”},{“name”:”Max. Cable Span”,”normalizedValue”:”165 ft”,”rank”:7,”value”:”165 ft”},{“name”:”Operating Force”,”normalizedValue”:””,”rank”:8,”value”:”Not Applicable”},{“name”:”NEMA Rating”,”normalizedValue”:”1, 12, 4″,”rank”:9,”value”:”1, 12, 4″},{“name”:”Indicator”,”normalizedValue”:”No Indicator”,”rank”:10,”value”:”No Indicator”},{“name”:”Switching Ability”,”normalizedValue”:”Single Cable”,”rank”:11,”value”:”Single Cable”},{“name”:”DC Contact Rating”,”normalizedValue”:”0.27 A @ 250 V”,”rank”:12,”value”:”0.27 A @ 250 V”},{“name”:”Case Material”,”normalizedValue”:”Zamak”,”value”:”Zamak”},{“name”:”Wiring Entry”,”normalizedValue”:”1/2 in NPT”,”value”:”1/2 in NPT”},{“name”:”IP Rating”,”normalizedValue”:”IP65″,”value”:”IP65″},{“name”:”Length”,”normalizedValue”:”9 in”,”value”:”9.0 in”},{“name”:”Depth”,”normalizedValue”:”4.13 in”,”value”:”4.13 in”},{“name”:”Thermal Amperage”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Width”,”normalizedValue”:”9.02 in”,”value”:”9.02 in”},{“name”:”For Use With”,”normalizedValue”:”Preventa XPS Safety Relays”,”value”:”Preventa XPS Safety Relays”},{“name”:”Cable Connection Location”,”normalizedValue”:”Left”,”value”:”Left”},{“name”:”Min. Current”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Standards”,”normalizedValue”:”CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC”,”value”:”CCC, CSA, CSA C22.2 No. 14 Machinery Directive 2006/42/EC, EN/IEC 60204-1, EN/IEC 60947-5, EN/IEC 60947-5-5, EN/ISO 13850, UL 508, Work Equipment Directive 2009/104/EC”},{“name”:”Length (Straight Wireway)”,”normalizedValue”:”9 in”,”value”:”9.0 in”},{“name”:”Series”,”normalizedValue”:”XY2CH”,”value”:”XY2CH”},{“name”:”Body Material”,”normalizedValue”:”zamak”,”value”:”zamak”},{“name”:”Overvoltage Category”,”normalizedValue”:”class I EN/IEC 61140 || class I NF C 20-030″,”value”:”class I EN/IEC 61140 || class I NF C 20-030″},{“name”:”[Uimp] Rated Impulse Withstand Voltage”,”normalizedValue”:”6 kV EN/IEC 60947-1″,”value”:”6 kV EN/IEC 60947-1″},{“name”:”Short-Circuit Protection”,”normalizedValue”:”10 A cartridge fuse gG EN/IEC 60269″,”value”:”10 A cartridge fuse gG EN/IEC 60269″},{“name”:”Compatibility Code”,”normalizedValue”:”XY2CE”,”value”:”XY2CE”},{“name”:”Local Signalling”,”normalizedValue”:”without pilot light”,”value”:”without pilot light”},{“name”:”Safety Level”,”normalizedValue”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″,”value”:”can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508″},{“name”:”Shock Resistance”,”normalizedValue”:”50 gn 11 ms EN/IEC 60068-2-27″,”value”:”50 gn 11 ms EN/IEC 60068-2-27″},{“name”:”Connections – Terminals”,”normalizedValue”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”,”value”:”screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²”},{“name”:”Marking”,”normalizedValue”:”CE”,”value”:”CE”},{“name”:”Number Of Cables”,”normalizedValue”:”1″,”value”:”1″},{“name”:”Product Or Component Type”,”normalizedValue”:”latching emergency stop rope pull switch”,”value”:”latching emergency stop rope pull switch”},{“name”:”[Ithe] Conventional Enclosed Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Cover Material”,”normalizedValue”:”Stainless Steel”,”value”:”stainless steel”},{“name”:”Protective Treatment”,”normalizedValue”:”TC”,”value”:”TC”},{“name”:”[Ui] Rated Insulation Voltage”,”normalizedValue”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14″,”value”:”500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14″},{“name”:”Ambient Air Temperature For Operation”,”normalizedValue”:”-25-70°C”,”value”:”-25-70°C”},{“name”:”Housing Colour”,”normalizedValue”:”red RAL 3000″,”value”:”red RAL 3000″},{“name”:”Tightening Torque”,”normalizedValue”:”0.8-1.2 N.m”,”value”:”0.8-1.2 N.m”},{“name”:”Product Certifications”,”normalizedValue”:”UL category NISD emergency stop devices || CSA || CCC”,”value”:”UL category NISD emergency stop devices || CSA || CCC”},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NC || NO”,”value”:”(21-22)NC || (13-14)NO”},{“name”:”Ip Degree Of Protection”,”normalizedValue”:”IP66 IEC 60529″,”value”:”IP66 IEC 60529″},{“name”:”[Ie] Rated Operational Current”,”normalizedValue”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”,”value”:”3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A”},{“name”:”Trigger Cable Anchor Point”,”normalizedValue”:”RH side”,”value”:”RH side”},{“name”:”Distance Between Cable Supports”,”normalizedValue”:”5-5 m”,”value”:”5-5 m”},{“name”:”Positive Opening”,”normalizedValue”:”with EN/IEC 60947-5-1″,”value”:”with EN/IEC 60947-5-1″},{“name”:”Trigger Cable Maximum Length”,”normalizedValue”:”70 m”,”value”:”70 m”},{“name”:”Mechanical Durability”,”normalizedValue”:”60,000 cycle”,”value”:”60000 cycles”},{“name”:”Vibration Resistance”,”normalizedValue”:”10 gn 10-300 Hz)EN/IEC 60068-2-6″,”value”:”10 gn 10-300 Hz)EN/IEC 60068-2-6″},{“name”:”Contact Operation”,”normalizedValue”:”slow-break”,”value”:”slow-break”},{“name”:”Cable Entry Number”,”normalizedValue”:”3 tapped entry 1/2\” NPT conduit entry”,”value”:”3 tapped entry 1/2\” NPT conduit entry”},{“name”:”Contacts Type And Composition”,”normalizedValue”:”1 NC + 1 NO”,”value”:”1 NC + 1 NO”},{“name”:”Device Short Name”,”normalizedValue”:”XY2CE”,”value”:”XY2CE”},{“name”:”Ambient Air Temperature For Storage”,”normalizedValue”:”-40-70°C”,”value”:”-40-70°C”},{“name”:”Maximum Resistance Across Terminals”,”normalizedValue”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”,”value”:”25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A”},{“name”:”Terminals Description Iso N°1″,”normalizedValue”:”NC || NO”,”value”:”(21-22)NC || (13-14)NO”},{“name”:”Thermal Current”,”normalizedValue”:”10 A”,”value”:”10 A”},{“name”:”Cable Span – Maximum”,”normalizedValue”:”164 ft”,”value”:”164 ft”},{“name”:”Action”,”normalizedValue”:”Maintained”,”value”:”Maintained”},{“name”:”Operating Temperature – Maximum”,”normalizedValue”:”158 deg F”,”value”:”158 Degrees F”},{“name”:”NEMA Enclosure Rating”,”normalizedValue”:”12, 4, 1″,”value”:”1, 12, 4″},{“name”:”Overall Depth”,”normalizedValue”:”4.13 in”,”value”:”4.13 in”},{“name”:”Operating Temperature – Minimum”,”normalizedValue”:”-13 deg F”,”value”:”-13 Degrees F”},{“name”:”Manufacturer Warranty Length”,”normalizedValue”:”18 mo”,”value”:”18 mo”},{“name”:”Overall Width”,”normalizedValue”:”9.02 in”,”value”:”9.02 in”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Multiple”,”value”:”Multiple”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Cable Pull Switch, 10A, Left, 1NO+1NC”