Multifunction Calibrator, 24V

$4723,99

Multifunction Calibrator, Voltage Measurement Range -10 to 75 mV, Loop Supply Voltage 24 V, Intrinsically Safe No, Pressure Modules 29, Measurement Functions Hertz, mV, Ohms, V, Source Current 24 mA DC, Current Measurement Range 0 to 24 mA DC, Basic DC Accuracy 0.02 Percent + 2 Counts; 0.02 Percent + 2 Counts (lower Display); 0.02 Percent + 2 Counts (upper Display); 0.025 Percent + 1 Count (via Tc Connector)

9999 in stock

SKU: GRG309008483 Category:

Description

[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Item”,”normalizedValue”:”Multifunction Calibrator”,”rank”:1,”value”:”Multifunction Calibrator”},{“name”:”Includes”,”normalizedValue”:”Alligator Clips, Stackable Test Leads, Test Leads”,”rank”:6,”value”:”Alligator Clips, Stackable Test Leads, Test Leads”},{“name”:”Standards”,”normalizedValue”:”ASNI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992, EN 61010-1:1993″,”rank”:10,”value”:”ASNI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992, EN 61010-1:1993″},{“name”:”Calibration Certificate”,”normalizedValue”:”NIST”,”value”:”NIST”},{“name”:”Resistance Source”,”normalizedValue”:”1,500 to 3,200 ohms”,”value”:”1,500 to 3,200 ohm”},{“name”:”Source Current”,”normalizedValue”:”24 mA DC”,”value”:”24 mA DC”},{“name”:”Thermocouple Temperature Range”,”normalizedValue”:”-200 Degrees to 1800 Degrees C, -328 Degrees to 3182 Degrees F”,”value”:”-200 Degrees to 1800 Degrees C, -328 Degrees to 3182 Degrees F”},{“name”:”Resistance Measurements”,”normalizedValue”:”1,500 to 3,200 ohms”,”value”:”1,500 to 3,200 ohm”},{“name”:”Voltage Measurement Range”,”normalizedValue”:”-10 to 75 mV”,”value”:”-10 to 75 mV”},{“name”:”Basic DC Accuracy”,”normalizedValue”:”0.02% + 2 Counts; 0.02% + 2 Counts (lower Display); 0.02% + 2 Counts (upper Display); 0.025% + 1 Count (via Tc Connector)”,”value”:”0.02% + 2 Counts; 0.02% + 2 Counts (lower Display); 0.02% + 2 Counts (upper Display); 0.025% + 1 Count (via Tc Connector)”},{“name”:”Pressure Modules”,”normalizedValue”:”29″,”value”:”29″},{“name”:”RTD Type”,”normalizedValue”:”Pt100, Ni120, Pt1000, Pt200, Pt500″,”value”:”Ni120, Pt100 (385), Pt100 (393), Pt100 (JIS), Pt1000 (385), Pt200 (385), Pt500 (385)”},{“name”:”Source/Simulate”,”normalizedValue”:”Hertz, mA, mV, Ohms, V”,”value”:”Hertz, mA, mV, Ohms, V”},{“name”:”Loop Supply Voltage”,”normalizedValue”:”24 V”,”value”:”24 V”},{“name”:”Frequency Measurement Range”,”normalizedValue”:”1 to 10 kHz”,”value”:”1 to 10 kHz”},{“name”:”Source Voltage”,”normalizedValue”:”-10 to 75 mV”,”value”:”-10 to 75 mV”},{“name”:”Max. Loop Current”,”normalizedValue”:”22 mA”,”value”:”22 mA”},{“name”:”Current Measurement Range”,”normalizedValue”:”0 to 24 mA DC”,”value”:”0 to 24 mA DC”},{“name”:”Manufacturers Warranty Length”,”normalizedValue”:”3 yr”,”value”:”3 yr”},{“name”:”Safety Rating”,”normalizedValue”:”ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992, EN61010-1:1993″,”value”:”ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992, EN61010-1:1993″},{“name”:”Thermocouple Type”,”normalizedValue”:”E, J, K, L, N, R, S, T, U”,”value”:”E, J, K, L, N, R, S, T, U”},{“name”:”Measurement Functions”,”normalizedValue”:”Hertz, mV, Ohms, V”,”value”:”Hertz, mV, Ohms, V”},{“name”:”Intrinsically Safe”,”normalizedValue”:”No”,”value”:”No”},{“name”:”Powered By”,”normalizedValue”:”(4) AA Batteries”,”value”:”(4) AA Batteries”},{“name”:”Frequency Source Range”,”normalizedValue”:”1 to 10 kHz”,”value”:”1 to 10 kHz”},{“name”:”Resistance Measurement – Maximum”,”normalizedValue”:”3,200 ohms”,”value”:”3,200 ohm”},{“name”:”Intrinsic Safety”,”normalizedValue”:”Not Specified Intrinsically Safe”,”value”:”Not Specified Intrinsically Safe”},{“name”:”Source Resistance – Minimum”,”normalizedValue”:”1,500 ohm”,”value”:”1,500 ohm”},{“name”:”Parameters Measured”,”normalizedValue”:”DC Voltage, Frequency, Resistance, RTD, TC”,”value”:”DC Voltage, Frequency, Resistance, RTD, TC”},{“name”:”Frequency Measurement – Maximum”,”normalizedValue”:”10 kHz”,”value”:”10 kHz”},{“name”:”Loop Current – Maximum”,”normalizedValue”:”22 mA”,”value”:”22 mA”},{“name”:”Source Voltage – Maximum”,”normalizedValue”:”100 mV”,”value”:”100 mV”},{“name”:”Battery Chemistry”,”normalizedValue”:”Alkaline”,”value”:”Alkaline”},{“name”:”Number of Batteries Required”,”normalizedValue”:”4″,”value”:”4″},{“name”:”Communication Protocol”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Source Frequency – Maximum”,”normalizedValue”:”10 kHz”,”value”:”10 kHz”},{“name”:”Source Current – Maximum”,”normalizedValue”:”24 mA”,”value”:”24 mA”},{“name”:”Thermocouple Temperature – Maximum”,”normalizedValue”:”2,498 deg F”,”value”:”2,498 Degrees F”},{“name”:”Includes Batteries”,”normalizedValue”:”Yes”,”value”:”Batteries Included”},{“name”:”Voltage Measurement – Minimum”,”normalizedValue”:”-10 mV”,”value”:”-10 mV”},{“name”:”Source Voltage – Minimum”,”normalizedValue”:”-10 mV”,”value”:”-10 mV”},{“name”:”Battery Size”,”normalizedValue”:”AA”,”value”:”AA”},{“name”:”Current Measurement – Minimum”,”normalizedValue”:”0 mA”,”value”:”0 mA”},{“name”:”Current Measurement – Maximum”,”normalizedValue”:”24 mA”,”value”:”24 mA”},{“name”:”RTD Temperature – Minimum”,”normalizedValue”:”-328 Degrees F”,”value”:”-328 Degrees F”},{“name”:”CAT Safety Rating”,”normalizedValue”:””,”value”:”Not Applicable”},{“name”:”Source Current – Minimum”,”normalizedValue”:”0 mA”,”value”:”0 mA”},{“name”:”Calibration Certificate Type”,”normalizedValue”:”NIST”,”value”:”NIST”},{“name”:”Source Frequency – Minimum”,”normalizedValue”:”1 kHz”,”value”:”1 kHz”},{“name”:”Digital Display Screen Type”,”normalizedValue”:”LCD with Backlight”,”value”:”LCD with Backlight”},{“name”:”Source Resistance – Maximum”,”normalizedValue”:”3,200 ohms”,”value”:”3,200 ohm”},{“name”:”Resistance Measurement – Minimum”,”normalizedValue”:”1,500 ohms”,”value”:”1,500 ohm”},{“name”:”Parameters Sourced”,”normalizedValue”:”AC Voltage, DC Voltage, Frequency, Resistance”,”value”:”AC Voltage, DC Voltage, Frequency, Resistance”},{“name”:”Thermocouple Temperature – Minimum”,”normalizedValue”:”328 deg F”,”value”:”328 Degrees F”},{“name”:”Frequency Measurement – Minimum”,”normalizedValue”:”1 kHz”,”value”:”1 kHz”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Malaysia”,”value”:”Malaysia”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “Multifunction Calibrator, 24V”