AC Current Probe

$762,99

Out of stock

SKU: GRG402650084 Category:

Description

[{“name”:”Promotion Restriction”,”normalizedValue”:”Not eligible for promotion”,”value”:”Not eligible for promotion”},{“name”:”Current Accuracy”,”normalizedValue”:”20 A 200 A 2000 A AC rms”,”value”:”20 A 200 A 2000 A AC rms”},{“name”:”Output”,”normalizedValue”:”Molded 4 mm safety plugs (not integrated)”,”value”:”Molded 4 mm safety plugs (not integrated)”},{“name”:”Phase”,”normalizedValue”:”< ±1° (45 Hz to 65 Hz)±10° (at 20 kHz)","value":"< ±1° (45 Hz to 65 Hz)±10° (at 20 kHz)"},{"name":"Safety Rating","normalizedValue":"EN 61010-031: 2002 EN 61010-2-032: 2002 EN 61010-1: 2001 600 Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.","value":"EN 61010-031: 2002 EN 61010-2-032: 2002 EN 61010-1: 2001 600 Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz."},{"name":"Storage","normalizedValue":"-40°C to +105°C (-40°F to 221°F) (head) -20°C to +85°C (-4°F to 185°F) (electronics)","value":"-40°C to +105°C (-40°F to 221°F) (head) -20°C to +85°C (-4°F to 185°F) (electronics)"},{"name":"Accuracy","normalizedValue":"at +25°C ±1% of range (45 Hz to 65 Hz)","value":"at +25°C ±1% of range (45 Hz to 65 Hz)"},{"name":"Calibration Frequency","normalizedValue":"10 Hz to 20 kHz (-3 dB)","value":"10 Hz to 20 kHz (-3 dB)"},{"name":"Features","normalizedValue":"2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator","value":"2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator"},{"name":"Max. AC Voltage","normalizedValue":"see Safety standards section 600 V AC rms or DC","value":"see Safety standards section 600 V AC rms or DC"},{"name":"Weight","normalizedValue":"180 g (6.34 oz) (head) 190 g (6.70 oz) (electronics)","value":"180 g (6.34 oz) (head) 190 g (6.70 oz) (electronics)"},{"name":"Cable length (head to electronics)","normalizedValue":"2 m (6.56 ft)","value":"2 m (6.56 ft)"},{"name":"Head Circumference","normalizedValue":"610 mm (24 in)","value":"610 mm (24 in)"},{"name":"Operating humidity","normalizedValue":"15% to 85% (non-condensing)","value":"15% to 85% (non-condensing)"},{"name":"Position sensitivity","normalizedValue":"with cable > 25 mm from the coupling ±2% of range”,”value”:”with cable > 25 mm from the coupling ±2% of range”},{“name”:”Temperature Coefficient”,”normalizedValue”:”±0.08% of reading per °C”,”value”:”±0.08% of reading per °C”},{“name”:”Head cable diameter”,”normalizedValue”:”14.3 mm (0.56 in)”,”value”:”14.3 mm (0.56 in)”},{“name”:”Dimensions (H x W x D)”,”normalizedValue”:”116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in)”,”value”:”116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in)”},{“name”:”Output sensitivity (AC-coupled)”,”normalizedValue”:”1 mV 10 mV 100 mV 1 mV per A”,”value”:”1 mV 10 mV 100 mV 1 mV per A”},{“name”:”Linearity”,”normalizedValue”:”10% to 100% of range ±0.2% of reading”,”value”:”10% to 100% of range ±0.2% of reading”},{“name”:”EMC standards”,”normalizedValue”:”EN 61326: 1998 +A1, A2, and A3″,”value”:”EN 61326: 1998 +A1, A2, and A3″},{“name”:”Noise”,”normalizedValue”:”8 mV AC rms (30 A) 2 mV AC rms (300 A, 3000 A)”,”value”:”8 mV AC rms (30 A) 2 mV AC rms (300 A, 3000 A)”},{“name”:”Load impedance”,”normalizedValue”:”100 k© minimum”,”value”:”100 k© minimum”},{“name”:”Operating temperature range”,”normalizedValue”:”0°C to +70°C (32°F to 158°F) (head and electronics)”,”value”:”0°C to +70°C (32°F to 158°F) (head and electronics)”},{“name”:”Head bend radius”,”normalizedValue”:”38.1 mm (1.5 in)”,”value”:”38.1 mm (1.5 in)”},{“name”:”External field”,”normalizedValue”:”with cable > 200 mm from the head ±1% of range”,”value”:”with cable > 200 mm from the head ±1% of range”},{“name”:”Country of Origin (subject to change)”,”normalizedValue”:”Unknown”,”value”:”Unknown”},{“name”:”Package Quantity”,”normalizedValue”:”1″,”value”:”1″}]

Reviews

There are no reviews yet.

Be the first to review “AC Current Probe”